SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-T-P-01-SA5"

P r o d u c t o f t h e W e e k Self Sealing Vacuum Cups Many applications use multiple vacuum cups to lift objects or multiple parts. If even one of the cups do not seal, there can be a loss of pressure to all cups. SMC addresses this problem with series INO Self Sealing Vacuum Cups. By utilizing a small mechanical check valve, it only opens when the cup comes in contact with a part.

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. DIGITAL PRESSURE SWITCH. 75.00000 lb. N59.

Knuckle Pin (Common with double clevis pin) Rod End Nut d d Dd9 C m l L t m t H B Material: Carbon steel Material: Carbon steel Part no. Applicable bore size (mm) 20 25 32, 40 50, 63 80 100 Applicable bore size (mm) Snap ring l D d H B C Part no.

through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB 20 25 32 29 32.5 35 19 23 27 16 20 24 12 15 19 26 32 40 42 50 62 20 25 31 22 25 31 9 10 11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com d n i n i W g c e t i r o i d n e p a t e p i P Leakage Voltage It must be noted that when connecting C-R element parallel to switching element, leakage current flows through C-R element and the leak voltage increases

(Hexagon socket head taper plug) 2-P (Hexagon socket head taper plug) P (Port) W CH LH RR1 SS NE RR2 SS H PP2 QQ PP1 QQ NH NC P (Port) P (Hexagon socket head taper plug) Back port (Refer to page 39.)

P. 76 KCT Use to branch connection of tubes of both side 90 direction. P. 78 KCL Union Y P. 76 KCU Use to branch connection of tubes in the same direction. 2 branched ports has a self-seal function. Check adaptor P. 77 KCJ Use to add the self-seal mechanism to a usual one-touch fittings, Series KQ. Bulkhead union P. 77 KCE Use to junction connection of tubes for installation of panel.

Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.

Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.

P/N 3/8 B5 x 2 3/8 B5 x 3 3/8 B5 x 4 3/8 B3 x 2 #2 1/2 Barb P/N 3/8 B2 1/2 x 2 3/8 B2 1/2 x 3 3/8 B2 1/2 x 4 3/8 B2 1/2 x 5 3/8 B2 1/2 x 6 3/8 B2 1/2 x 7 #3 Barb P/N 3/8 B3 x 2 3/8 B3 x 3 3/8 B3 x 4 3/8 B3 x 5 3/8 B3 x 6 #4 Barb P/N 3/8 B4 x 2 3/8 B4 x 3 3/8 B4 x 4 3/8 B4 x 5 Thread Size 1 Barb # (Size) Quantity of Barbs Part Numbering Example 52 Available with #1, #2, #2

Mounting height Reduction by 15 to 20% (Compared to P/A series MGQ) Guide Table Series MGF Built-in non-rotating mechanism Internal guide pin prevents table rotation. 40, 63, 100 Built in T-slots T-slots are provided on 3 faces of the body (except port face), allowing mounting for various brackets. (Not suitable for mounting the cylinder itself.)

Refer to p.0-39 to p.0-43 for Safety Instructions and common precautions and refer to p.1.4-5 for those on CM2 series. Handling Warning q In the direction of low friction operation, speed control must be effected through the meter-in system.

(Refer to p.1.1-6 for further information on specifications.) Ass'y part No.

2 u t e w CHQ CHK CHK CHN CHM CHS CH2 32 to 100 20 to 25 CHA Related Products DWithout auto switch Parts List Replacement Parts/Seal Kit Content Description No. Material Note Bore size (mm) Seal kit no. 1 20 Rod cover Aluminum alloy Black anodized CHKD20-PS 2 25 Head cover Aluminum alloy Black anodized CHKD25-PS 3 32 Cylinder tube Aluminum alloy Hard anodized CHKD32-PS 40 Nos. u, !0, !

Approx. 1.7 mm Colours Brown, White, Black, Blue Sheath Material Lead free heat and oil resistant PVC Finished O.D. 6 -66No.LV50***-OMQ0002-G Characteristics Chart Flow characteristics (pressure loss) LFE1 LFE2 0.02 0.02 P r essur r e l oss[ M P a] 0.015 0.015 P r essur e l oss[ M P a] 0.01 0.01 0.005 0.005 0 0 0 5 10 15 20 0 20 40 60 80 100 Fl ow r at e[ L/ m i n] Fl ow r at e[ L/ m i n]

8.4 NO X X PE NC 30.5 30.5 116.1 98.6 91.6 91.6 2(A) 3(R) 66.8 57.6 1(P) 43.8 43.8 34 34 71 (P port) Rc 1/2, 3/4, 1 (R port) Rc 1/2, 3/4, 1 (A port) Rc 1/2, 3/4, 1 5-5-12

CH kPa 4 3 2 1 SW t e AV y D-IN RUN UP SET P-ON AU DOWN STOP READ r u AF i AR o Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com t y u i o IR !

Proper use of float type auto drain See P.6 3 Auto Drain Valve AD402-A Series Construction/Dimensions 82 Width across flats 30 IN Port size 1/4, 3/8, 1/2 q e w r 184.4 t y N.O.: Black N.C.: Gray Clearance for maintenance 30 Port size 3/8 Drain discharge Drain 27 Width across flats Component Parts Port size 1/4, No.

7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !4 Open condition Component Parts Note Note No. q Description Material No. Description Material Bushing B !