(mm) Weight (g) M A L D Part No. 3.2 4 33.5 34.5 36.5 18.5 KAR23-04 18.5 17.5 18 15.5 9.6 3.4 2.9 2.3 2.1 5 KAR04-06 KAR04-08 5.6 5.6 6 8 10.4 4 16 12.8 10 KAR04-10 39.5 37 39.5 3.6 3 KAR06-08 8 18.5 6 10 KAR06-10 17 12.8 KAR06-12 42 5.2 12 20 3.5 13.1 13.1 8 KAR08-10 41 4.5 18.0 18.0 10 20 18.5 15.2 KAR08-12 42 5.1 12 10 KAR10-12 42 33 32.8 32.8 12 20 21 17 139
PV SV 12. Select contact input signal 2 from the table below with [] key or [] key, and confirm by pressing SEL.
Metric Size Applicable tube Tube size 4 6 8 10 12 23 04 06 08 10 12 Applicable series 3.2 TMH-23J TMH-04J TMH-06J AS1002F AS2002F AS2052F AS3002F AS4002F TMH-06 TMH-07 TMH-08 TMH-10 TMH-12 TMH-13 Holder for speed controller Note) The applicable TMH for AS1002F-02 is not available.
Fig. 12-1 EX245-DY1 EX245-DY1 EX245-DY1-37 75 No.EX##-OMY0006CN 12.2. Table 12-1 EX245-DY1 (W x L x H) mm 54 x 120 x 61 280 g , PBT 24 V DC 1.6 V 50 mA 4 x M125 A code 2 / , US2 30 V /1 0.5A /1 2 A 1 1 8 PNP 76 No.EX##-OMY0006CN 12.3. /SI IP65M12 M12,5 , Table 12-2 EX245-DY1 (TOP View) 1 N.C.() 2 2 DO ( n+1) 3 5 1 3 0 V (/) 4 DO ( n) 4 5 FE/ 12.4.
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-8 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-R005 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Circulating fluid flow rate Circulating fluid flow rate . 5-12 Circulating fluid discharge pressure Press PV . 5-12 Compressor circuit High pressure side High Press. . 5-12 Compressor circuit Low pressure side Low Press. 5-13 Circulating fluid electrical conductivity DI PV . 5-13 Key lock condition display KEYLOCK . 5-13 Startup operation status display START UP . 5-14 Anti-freezing status
Outlines of Product . 7 2.1 Features . 7 2.2 Product configuration . 8 2.3 How to Order. 9 2.4 Option . 10 (1) Battery-Less Absolute Encoder compatible . 10 [1] Actuator cable . 10 [2] Actuator cable for actuator with lock (for sensor and lock) . 11 (2) Incremental Encoder compatible . 12 [1] Actuator cable [5m or less]. 12 [2] Actuator cable [8 20m] . 12 [3] Actuator cable for actuator with
Setting Data Entry . 59 11.1 Step data . 59 11.2 Basic parameter . 62 11.3 Return to origin parameter . 65 11.4 Operation parameters . 66 12.
Data writing mode.36 12. Memory map .37 12. 1 Memory assignment.37 12. 2 Controller IF status flagIN Data.43 12. 3 Gateway unit status flagIN Data.43 12. 4 Gateway unit control flagOUT Data.45 13. Precautions for controlling the controller (LEC).46 13. 1. Communication delay between the gateway unit unit and the controller (LEC) 46 13. 2.
Close the front door. 12. Connect the power cable to the power breaker on customer side (primary side).
, 16, 20 25, 32, 40 50, 63, 80 100 6, 10 15, 20 25, 32 12, 16, 20 25, 32, 40 50, 63, 80 100 10, 16 20 25, 32 12, 16 20, 25 32, 40 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 20, 25 32, 40 50, 63 12, 16 20, 25 6, 10 16 20, 25, 32 40, 50 10, 15 25 6, 10 16 20, 25 32, 45 Bore size (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed Rubber bumper (basic cylinder section) Shock absorber
to 24 VDC ZNR ZNR 12 to 24 VDC SOL DC () 100 to 200 VAC SOL 2 DC () 2 ( ) PNP open collector output Conduit terminal DIN type connector With indicator light AC Circuit Conduit terminal With indicator light DC circuit DC (+) 1 ( ) 1 DC (+) MAX 80 mA Rectifying device OUT Load 12 to 24 VDC ZNR ZNR 100 to 200 VAC 12 to 24 VDC SOL SOL DC () 2 ( ) 2 DC () LED indicator light ZSE ISE DIN type
32 40 50 ZP50U 53 7 0.8 0.8 0.8 1 3 3 3.5 4 4 4.5 6.5 7.5 Put in the symbol for material at the end of model no. 7 7 7 7 13 13 13 15 15 15 18 18 14.7 12 12 12 12 12 12 12.5 14 14 14.5 18.5 19.5 U04 ZP04U 4.8 1.6 U06 ZP06U 7 2.5 U08 ZP08U 9 2.5 U10 ZP10U 12 4 7.7 U13 ZP13U 15 4 7.7 U16 ZP16U 18 4 8.2 U20 ZP20U 23 4 9.5 U25 ZP25U 28 4 9.5 U32 ZP32U 35 4 10 Model Size D10 A 10 ZP10D B 12
NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) Reed switch Solid state switch A96V A96 5 V IC Yes Yes Grommet A93 M9N M9P M9B F9N F9P F9B F9NW F9PW F9BW F9BA A93V F9NV F9PV F9BV F9NWV F9PWV F9BWV 100 V 24 V 12 V Relay, PLC 5 V, 12 V IC 12 V 5 V, 12 V IC Relay, PLC 24 V Grommet 12 V Diagnostic indication (2-color) 5 V, 12 V IC
Stroke (mm) Refer to the standard stroke table on Page 12.
, Ion exchange resin*12 Temperature range [C] 5 to 40 Pressure range [MPa] 0.3 to 0.5 Required flow rate (50/60 Hz)13 [L/min] 8 12 Facility water system Inlet-outlet pressure differential of facility water [MPa] 0.3 or more Port size Rc3/8 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Power supply Single-phase 100 VAC (50/60 Hz), 115 VAC
Note 3) Reference dimensions AS421F-04-12 12 20.9 22 49.5 35.2 101 Note 1) ( ) are the dimensions of NPT thread. Note 2) Reference thread dimensions after installation.
Normally closed Normally open Double acting VNB0 VNB02 VNB03 7.7 7.8 1 4 40 12 (P1) 10 (P2) 12 (P1) 6.3 6.4 2 Air operated 11.4 11.5 50 1 2 1 2 1 2 Note) The flange should be JIS B 2210 10K (ordinary type) or its equivalent. 10 (P2) Specifications VNB1 VNB12 1 4 Fluid Water/Oil/Air/Vacuum, etc. 5 to 60C Note 1) VNBA, VNB1 Fluid temperature B C 12 (P1) 12 (P1) 5 to 99C Note 1) (Water, Oil
110 R 5 8 12 RR 5.3 8.5 11 NV 4.5 6.6 9 NW 85.2 124.8 150.1 NX 7.3 10.5 14 PP 5.3 8 16 Q 140 185 290 QQ 16.4 20.4 25.5 Model MY2HT16G MY2HT25G MY2HT40G U 5 6 8 UU 3 4.4 2 VV 10.5 15.3 29 X 7 9 12 XX 12 14 23 Y 5 8 12 Z 160 210 330 "P" indicates cylinder supply ports.
Solid state switch Reed switch Yes 5 V A96V A96 Grommet A90V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV A90 A93 M9N M9P M9B F9NW F9PW F9BW F9BA 100 V 5 V, 12 V 12 V IC circuit Relay, PLC No 2-wire 24 V Yes 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V Relay, PLC Yes IC circuit Diagnostic indication (2-color display) 5 V, 12 V Grommet 12 V 2-wire