Add L to the end of the part number when 3 m is desired, M when 1 m, and Z when 5 m. Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
23.5 28 ( ): Single acting, spring return 16 Series CUJ Auto Switch: Proper Mounting Position (Detection at Stroke End) D-F8 D-M9/M9W When detecting extended stroke end When detecting retracted stroke end 10 mm or more 10 mm or more Note 2) A B A B Stroke A + Stroke B D-F8 D-M9/M9W Bore size (mm) Double acting Single acting A B Single acting Double acting A B A B A B 6 8 10 12 16 20 1
B Ht Auto Switch Mounting Position D-F5, D-F5W D-J5, D-J59W D-F59F, D-F5BAL D-Z7, D-Y59, D-Y7BAL D-Z80, D-Y69, D-Y7W(V) D-Y7P(V) D-A5 D-A6 D-A59W D-F5NTL D-A3, D-G39 D-A44, D-K39 D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 0 10.5 1.5 14 9.5 22 4.5 17 2 14.5 0 10.5 1 13.5 40 0 21.5 1.5 25 9.5 33 4.5 28 2 25.5 0 21.5 1 24.5 50 0 23 2 26.5 10 34.5 5 29.5 2.5 27 0 23 1.5 26 63 0 28
Note) This is an assembly of a bracket and set nut (2). Note 1) Note 2) G46-4-01 (Rc type) / G46-4-N01 (NPT type) / G46-P4-N01-X30 (NPT, Z type). Part number for 0.2 MPa: G36-4-01 (Rc type) / G36-4-N01 (NPT type) / G36-P4-N01-X30 (NPT, Z type). With O-ring (1 pc.) and mounting screw s (2 pcs.). Part number for 0.2 MPa: GC3-4AS(-J)-D (Rc, NPT type) / GC3-P4AS(-J)-D-X30 (NPT, Z type).
When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.
Semi-standard symbol: "6C" Port thread Semi-standard symbol: "6" Port thread Part No. type Part No. type Rc C2SK-6C-D G Rc C2SF-6-A-X401 G NPT C2SK-6C(Z)-D NPT C2SF-6(Z)-A-X401 Semi-standard symbol 2 Semi-standard symbol: "2" Port thread type Part No. Rc C2SF-2-A-X401 G Appearance and part No. NPT C2SF-2(Z)-A-X401 Note 1) Part No. includes Bowl seal . Refer to [11.
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position
Dimensions L, Z, and ZZ are reference dimensions for installing a double knuckle joint, which may be used as a guide.
D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-F5LF D-P5DWL Bore size (mm) A A A A B A A A A B B B B B B B 32 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 63 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 80 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 100
Dimensions L, Z, and ZZ are reference dimensions for installing a double knuckle joint, which may be used as a guide.
A sensor connector cannot be taken apart for reuse once it is crimped. If the wire arrangement is incorrect or if the wire insertion fails, use a new sensor connector. For connection to SMC Series PSE300 pressure switches, use sensor connectors (ZS-28-C) or econ connectors listed below. ZSE ISE PSE Z I SE3 Operating Environment Warning PS 1.
m3 x g x X m4 x g x Y M3 m4 x g g: Gravitational acceleration Dynamic moment z Mounting orientation Horizontal Ceiling Wall Vertical M1 x a x mn x g 1.4 100 Dynamic load FE 1 3 a Dynamic moment M1E x FE x Z a M2E Dynamic moment M2E is not generated. 1 3 M3 M3E Note) Regardless of the mounting orientation, dynamic moment is calculated with the formulas above.
Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment M Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z 1.4 100 x a x mn x g a a 1 3 x FE x Z ME Dynamic moment Dynamic moment ME does not occur.
Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24-M3 x 0.5 B phase J A B C D A COM COM COM B 12 VDC GND F.G.
Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24-M3 x 0.5 B phase J A B C D A COM COM COM B 12 VDC GND F.G.
Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24-M3 x 0.5 B phase J B C D A A COM COM COM B 12 VDC GND F.G.
mm; X, Y, Z for 2 hours each Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24 x M3 x 0.5 B phase J B C D A t A COM COM COM B 12 VDC GND F.G.