Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: T (Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: T (Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: F (G)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Body Size: 4000, Thread: F (G), Port Size: 04 (1/2), Option: G (Round Type Pressure Gauge w/Limit Indicator), Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right
Confirm how to increase the number of stations for SJ series manifolds. To remove a valve connection, loosen the 2 screws securing the valve to the DIN rail. The word “FREE” will be visible when the valve lock switch of each block is slid toward the coil. In this state, remove the end block assembly and the supply/exhaust lock assembly, and increase the number of valve stations.
After
Yes, a terminating resistor is required. The LATCA series card motor controller communication circuitry does not have a built-in terminating resistor.
If there is no terminating resistor, there will be interference during communication.
An SMC terminating resistor (LEC-CGR) can be ordered, or a terminating resistor can be prepared separately by the customer.
Note) “LEC-CGR” is an
These graphs show the range where the set pressure can be maintained when the outlet pressure rises above the set value and exhaust is performed.
In the graphs, the nearly horizontal part indicates the range where the set pressure can be maintained by IR control, and the diagonal part indicates the range where the pressure rises because the exhaust flow rate is too large to maintain the
Terminal No. 1: + (plus)
Terminal No. 2: - (minus)
Note 1) There is no polarity for some types of valves.
Note 2) For SGC and SGH series valves, refer to the “Specific Product Precautions” section in the respective catalogs.
VQC1000/2000 series valves do not come with mounting screws or gaskets. For VQC4000/5000 series valves, when a valve is ordered individually, it comes with a mounting screw but no gasket. VQC1000/2000 series valves do not require separate mounting screws as there are clamp screws built into the manifold.
VQC4000/5000 series valves do not have common polarity.
② For manifolds with serial transmission kits, whether the valves are positive common or negative common depends on the type of protocol. For VQC1000/2000 series valves, install valves with the same common specification as the common specification of your protocol.
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
1 Mini-rotary Actuator Rack & Pinion Style Series CRJ Size: 05, 1 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D20PAT.
Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: DO (DIN Connector w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: DO (DIN Connector w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: DO (DIN Connector w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: N (NPT)
Actuation: 3 (3 Postion Closed Center), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal, w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate)
Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: DO (DIN Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: C6 (Body Ported ø6 One-touch Fitting)