1 V FUNC DC(-) DC(+) OUT -P PNP 1 Max.80 mA 1 V FUNC DC(-) DC(+) OUT1 OUT2 -A NPN 2 Max.28 V80 mA 1 V FUNC DC(-) DC(+) OUT1 OUT2 -B PNP 2 Max.80 mA 1 V FUNC DC(-) -19No.PS-OML0002CN-G DC(+) OUT1 -C OUT2 NPN 1 Max.28 V80 mA 1 V 1 k FUNC DC(-) DC(+) -D OUT1 NPN 1 Max.28 V80 mA 1 V 12 V 300 24 V 600 50 OUT2 FUNC DC(-) DC(+) OUT1 -E OUT2 PNP 1 Max.80
l h + l ZZ1 + l + Stroke Bore size (mm) Stroke range (mm) A AL B BN BP BQ C CL D E EA F FA G GA GB GL GR J 125 140 160 16 Up to 1000 50 47 145 205 1/2 3/8 115 120 36 90 63 35 14 155 23 25 30 M14 x 1.5 16 Up to 1000 50 47 161 245 1/2 3/8 128 136 36 90 63 35 14 180 28 30 30 M14 x 1.5 18.5 Up to 1200 56 53 182 290 1/2 3/8 144 144 40 90 63 43 14 215 35 35 35 M16 x 1.5 Bore size (mm) K KA M MA
No. 1 Moving Relationship between the analogue input signal direction and the piston rod movement direction 4 mA 20 mA OFF (Default) Standard Set point (*1) Piston rod Retracted end 20 mA 4 mA ON Reverse Piston rod Set point (*1) Retracted end *1 Set point: Position set by Calibration. Refer to "7-2. Calibration" of Operation Manual (K35-OMW0030). 2-2.
Seal kits are sets consisting of items 46, 48, 49, 53, 54 and 57, which can be ordered using the seal kit for each cylinder bore size. 4 Series CNS Dimensions Basic type/CNSB 2-MA Effective thread depth R Rc(PT) BQ Plug with breathing hole CL M GA BC element T G G FA GB Rc(PT) BP Unlocking port 2-Rc(PT) P GL GR Width across flats KA Cylinder port MM Q D EA E V AL A K F VA BN C B N N 4-J
45 mA or less (70 mA or less for current output) Current consumption Panel mount/Bracket Option 16-2-3 4 High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2 m) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less
Note 1) In case of types with no air cushion, a rubber bumper is used. 6-6-7 7 Series MB Without Mounting Bracket Basic: (B) Cushion valve WV Port G 2-RcP MM G With rod boot E E D e MB Effective thread 2 x 4-J C B A K F N MA 13 9 f l N h S + Stroke H ZZ + Stroke Without Air Cushion Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588
A voltage drop may cause the air dryer to stop operating. *1 Select an earth leakage breaker with a sensitivity of leak current of 30 mA and a rated current of 10 A. <200 VAC> Connect the power supply to the terminal block. Install an earth leakage breaker*2 suitable to each model for the power supply.
Self-diagnosis: 5% F.S. or less Switch output PNP open collector output: Max. 80 mA Hysteresis: 3% F.S.
Air purge Power supply voltage Sensing DC mode Autobalance sensor [Body-mounting type] : 300 mA or less Autobalance sensor [High-precision type] : 200 mA or less When sensor is not used : 170 mA or less Current consumption Pulse DC mode DC mode Discharge stop signal Maintenance detection signal 170 mA or less Connected to 0 V (Voltage: 5 VDC or less, Current consumption: 5 mA or less) Connected
TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input signal 1: Run/Stop (Default setting) 4.7 k 1 k 3 Contact input
48 VAC, DC or less: 40 mA 100 VAC, DC or less: 20 mA Center of F.R.L. body D A P * For detailed specifications of the IS10 series, refer to the IS10 series section on the SMC website: https://www.smcworld.com Model P A B C D Applicable AC size IS10T-20-D 1/8, 1/4 28 77.6 60.1 42 AC20-D IS10T-30-D 1/8, 1/4, 3/8 31 85.6 64.1 53 AC30-D IS10T-40-D 1/4, 3/8, 1/2 39 93.6 68.1 71 AC40-D IS10T-
The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. Internal circuit RE A B REC 3. Output circuit CX There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
Slide bearing Ball bushing bearing M L M 80 50 Y7BW MVGQ Cylinder 1 0 5 L 4 MA VF3 Valve Speed controller specifications Type of actuation 2 position single solenoid 2 position double solenoid 1 2 MA MB Meter-out Meter-in Option Please consult with SMC for 3 position type.
30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/
or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal
() DC15 V(1 M) 1 (26.4 V ) NPN PNP 2 80 mA DC30 V(NPN ) 1 V (80 mA ) () 100 ms.500 ms1 s2 s 15 V( 1 k () (25 ) 1F.S. 420 mA() 600 (DC24 V) 50 () (25 ) 1F.S
or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal
or less Data Weight 45 g Maximum load current: 80 mA NPN open collector Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D300, PF2W300, PF2W330) Maximum applied voltage: 30 V 2 outputs Environmental resistance Note 4) Output specifications Switch output PNP open collector Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D301
This is a legacy product. Please contact us for the latest version.sales@ocaire.com