Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: Rc, Control Unit: MP (Air Filter w/Manual Drain, Regulator, Air Release Valve, Pressure Switch), Voltage of Air Release Valve

Model: 50R (Side Ported/External Pilot), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 3 Stations, P, E Port Location: B (Both Sides), A, B Port Size: 01 (1/8)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)

.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)

Manifold with Stainless Steel Plate: S, Model: 51S (EX260), SI Unit: EAN (Negative Common, PNP; EtherNet/IPâ„¢; 32 Outputs; M12 Connector), Wiring Type: All Double Wiring, Valve Stations: 08 (8 Stations, All Double Wiring), Port Size: 01 [4(A)/2(B) Port: 1/8; 1(P)/3(EB), 5(EA) Port: 1/4], Thread Type: N (NPT)

Model: 50 (Side Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 12 Stations, P,E Port Location: D Side, A,B Port Size: 01 (1/8), Thread: N (NPT)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)

Model: 50 (Side Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 5 Stations, P,E Port Location: D Side, A,B Port Size: 01 (1/8), Thread: N (NPT), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

Model: 50 (Side Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 12 Stations, P,E Port Location: D Side, A,B Port Size: 01 (1/8), Thread: N (NPT), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 9 Stations, Passage: 2 (P and EA,EB: Common, Port A,B: Bottom), Port Size: 01 (1/8), Thread: N (NPT)

Series: 3 (JSY3000), Type: 40 (Side Ported), Valve Stations: 4 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: 01 (1/8)

.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)

L CKZP 57 T 25 TF TF T 25 CKZP 71 Switch output display Bore size Retracted Extended Nil Yellow Red 71 71 mm R Red Yellow Port thread types TF G TN NPT Proximity switch T TURCK P P&F Stroke 25 25 mm 50 50 mm Proximity Switch Specifications Specifications Bore size 57 71 Manufacturer TURCK P&F Power supply voltage 10 to 30 VDC 10 to 30 VDC Fluid Air Output N.O., PNP N.O., PNP Maximum operating

r cl cl en nt er er e tm e m nt nt is us u t u w C 0 us o 90 k o c lo o C l dj C C 19 dj se c Cl 1 A k A A wi e w oc ge dj k A is oc k ng dj u wi e Cl an st us se ro ra m r ta t ot m r d at ti n e n io on e n e on nt e nt tio nd r r a a ti n n g ta e 5 9 g ta e 9 ro 5 ro m m u im u im ax M ax M Note) The drawing shows the rotation range of the positioning pin hole.

Connect head cover tubing wisely with consideration of surrounding conditions. 15 Driving Direction Left Right Brake O per ating P ort Brake Release P ort Head Cover-WL Head Cover-WR Tube Part No. 1 2 3 4 5 6 Head Cover Type Head Cover-WL Head Cover-WR Tubing Side Front Side Bottom Front Side Bottom Driving Left A C E G I K Direction Right B D F H J L Note

through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB 20 25 32 29 32.5 35 19 23 27 16 20 24 12 15 19 26 32 40 42 50 62 20 25 31 22 25 31 9 10 11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard

P/As seal material has undergone a high vacuum degassing process. Orifice conductance In the case of a A (cm2) hole in an ultra-thin plate, the conductance C results from V the average velocity of the gas, R the gas constant, M the molecular weight and T the absolute temperature.

Cup Calculation W: Lifting force [N] P: Vacuum pressure [kPa] S: Cup area [cm2] t: Safety factor Horizontal lifting: 4 or more Vertical lifting: 8 or more Theoretical lifting force table The theoretical lifting force (not including the safety factor) can be determined by the cup diameter and vacuum pressure.

The used of turbine oil at temperatures lower than 0C leads to increased viscosity and may cause the valve to malfunction. d n i n i W g c e t i r o i d n e p a t e p i P Leakage Voltage It must be noted that when connecting C-R element parallel to switching element, leakage current flows through C-R element and the leak voltage increases. 2 thread to be left exposed Clamping Torque Switching

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Buffer mounting (Male thread) Buffer mounting (Male thread) Mounting Male thread Female thread Female thread Vacuum entry port Female thread Common Female thread Female thread Female thread P. 13-11-91 to 92 P. 13-11-86 to 88 P. 13-11-86 to 88 P. 13-11