AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 Series
-2VEX-OMV0001 / *3) 1 1.5 *3)1 1 () [] -3VEX-OMV0001 VEX1 Series / / C-R ( )C-R SDS DC VEX1101, VEX1201, VEX1301 2% () VEX1501, VEX1701, VEX1901 3% AC VEX1101, VEX1201, VEX1301 20% VEX1501, VEX1701, VEX1901 15% (SSR)AC 1) (C-R ) OFF () 2)() P2 N.O.() ZNR 1V 0C () 4 VEX-OMV0001 VEX1 Series / () DC 1(P)2(A) 1 ()ISO VG32 1) 2 ( )ISO VG32 (SDS) M5 1/61/4 11.5Nm ) 2)R,
mode] In the 3 step setting mode, the set value (P or n) and hysteresis (H) can be changed.
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 9 Position for application of grease Table 10 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 20 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.9, ) Pay attention to the mounting direction of the seal.
I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT CONSULT
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel (SUS304) M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel
P 1 Silencer VEX Solenoid Tightening Torques for Silencers Applicable tightening torque (N.m) 12 to 14 Connection thread AN 1 4 22 to 24 3 8 28 to 30 1 2 28 to 30 3 4 36 to 38 40 to 42 1 4 1 2 48 to 50 48 to 50 R R R R R 1 R 1 R 1 R 2 Inlet pressure for silencer AMC 4.
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES OFF P-1 P-2 GPM gal (US) Real-time flow rate GPM = gal (US)/min "P" Window comparator mode H : Hysteresis Note ) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.
SYJ514 With valve 16 4 Multistage Ejector Series ZL Dimensions/Series ZL112 (without Valve) 2-5.4 Mounting hole Scale: 40% Label 50 117 Exhaust with silencer P Standard ZL112 20 V 4.5 166 56 Exhaust port Rc1/2 35 P Port exhaust ZL112P V 14 Vacuum pressure gauge Exhaust with silencer 2-5.4 Mounting hole P With vacuum pressure gauge ZL112-G V Exhaust with silencer Vacuum adapter Rc1/8 2-5.4
Output circuit Surge voltage 24 V 0 V sol. 1: Holding 60 V R Surge voltage 24 V 0 V Internal circuit sol. 2: Non-holding 60 V R Surge voltage 24 V 0 V Large capacity load: Holding 60 V R Relay Power supply circuit breaker 24 VDC Figure 1. Surge intrusion circuit example (NPN outlet example) Piping Output circuit Caution Surge voltage 24 V 0 V 1.
Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 16 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig 6, ) Pay attention to the mounting direction of the seal. Apply grease all over the seal and inner surface of the bushing as shown in Fig. 7.
L = Stroke 1 2 , or more than 100 mm 1 7 5 4 6 2 6 5 7 3 L L Fig. 11 Position for application of grease Table 10 Amount of grease units: g Stroke 32 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1 1.5 2 3 26 3-2-4.
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 14 Position for application of grease Table 9 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 28 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.14, ) Pay attention to the mounting direction of the seal.
L100mm, or stroke 1 2 Grease on the outer circumference Grease in the groove Rod seal part Approx. 3g About 1cm Amount of grease Fig. 5 Position for application of grease Table 1 Amount of grease Unit: g Stroke 40 P o s i t i o n f o r g r e a s e Bore size At 100st 3 to 4 50st added 1 19 3-2-4.
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 12 Position for application of grease Table 9 Amount of grease A units: g Stroke 32 40 50 63 80 100 125 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 15 to 17 50st added 1 1 1 1.5 2 3 3 28 3-2-4.
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, ZSE20, "VACUUM SWITCH
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, ZSE20, "VACUUM SWITCH
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: -
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: None, Option 3: Operation Manual, Calibration Certificate
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: Operation Manual, Calibration Certificate