J F H K J (D) F H 2 x P Port size 2 x P Port size Conduit terminal: T DIN terminal: D M N E (N) (M) E C C 25 32 31.5 (44) A A G1/2 L L G1/2 OUT IN OUT IN Applications B B (D) F H (D) F H K J K J 2 x P Port size Cable 6 to 12 2 x P Port size With bracket e a g d Bracket h b i (mm) Model A B C D E F H J K Port size P N.C. 1/4, 3/8 1/2 3/4 1/1 40 52 65 70 22 29.5 36 40.5 20 26 32.5 35 30 37
J 70C Nylon tarpaulin K 110C* Neoprene cloth * Maximum ambient temperature for the rod boot only. Mounting Bracket Part No.
MGPM, MGPL Common dimensions (mm) Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL P PA PB PW 42 29 11 7.5 8 8.5 9 M4 x 0.7 10 12 13 15 M4 x 0.7 4.3 4.3 5.6 5.6 M5 x 0.8 6 8 10 12 58 64 83 93 8 8 9.5 9.5 13 8 8 10 10 M4 M4 M5 M5 4.5 4.5 5.5 5.5 8 5 5 6 6 13 15 18 21 18 26 30 36 42 13 15 18 21 18 22 24 30 12 16 20 25 10, 20, 30, 40, 50, 75, 100 125, 150
K K K C C C C U U U U O O O O S S S S H H H H L L L L to to to to Possible to change to the optional mounting angles.
PA+stroke GB Q (Plug) MG FB C+stroke FA G S B+stroke A+stroke E MGP MGPM, MGPL Common Dimensions MGQ Standard stroke (mm) Bore (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL P PA PB PW MGG 42 29 11 7.5 8 8.5 9 M4 X 0.7 10 12 13 15 M4 X 0.7 4.3 4.3 5.6 5.6 M5 X 0.8 6 8 10 12 58 64 83 93 8 8 9.5 9.5 13 M4 M4 M5 M5 4.5 4.5 5.5 5.5 8 8 8 10 10 13 15 18 21 18 13 15 18 21 5 5 6 6 18 22
O F 34 10 one-touch fitting Combination of D: With auto drain (N.O.) and H: For medium air pressure D I L T (Accessory) Bracket N K J M U V E B IN OUT 20 1/4 female threaded C Option H A J: Drain guide 1/4 female threaded Drain G M5 Maintenance space 20 1/4 female threaded (mm) A Model Port size Bracket related dimensions B C D E F G H 173 I 56 J 20 K 5 T 6 U 6 L 12 M 6 V 10 N 35 O 54 P 70
MGT MGPM, MGPL, MGPA Common Dimensions [mm] Bore size [mm] Standard stroke [mm] B C DA FA FB G GA GB GC H HA J JA JB JC K L MM ML NN OA OB OL P Nil TN TF 80 25, 50, 75, 100 125, 150, 175, 200 250, 300, 350, 400 96.5 56.5 22 16 24 91.5 19 16.5 14.5 202 M12 45.5 38 7.5 15 46 54 M12 x 1.75 25 M12 x 1.75 10.6 17.5 3 Rc3/8 NPT3/8 G3/8 100 116 66 26 19 31 111.5 22.5 20.5 18 240 M14 55.5 45 10.5
Sysmac G5 R88M-K OMRON Corporation MINAS-A4 MSMD Panasonic Corporation MINAS-A5 MSMD/MHMD is FANUC CORPORATION S-FLAG MA/MH/MM NIDEC SANKYO CORPORATION SV SV-M/SV-B KEYENCE CORPORATION ALPHA5 GYS/GYB FUJI ELECTRIC CO., LTD. FALDICGYS AR AR ORIENTAL MOTOR Co., Ltd. AZ AZ Ezi-SERVO EzM FASTECH Co., Ltd. MP-/VPMP/VP Rockwell Automation, Inc.
(Fluid can be supplied manually for models without option -K if the side panel is removed.)
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com WA Z Bottom view Section XX Z WA L 4-MM depth ML Section XX HA: T-slot for hexagon bolt 4-NN through 4-OA through 4-OB counterbore depth OL X 0.02 X 0.02 DA VB VA R U T X H PW DB XA depth 6 H7 XA depth 6 H7 2-P (Rc, NPT, G) GA 2-P PB (Rc, NPT, G) J K
2.7 k DC24 V DC24 V 3 0 V 3 0 V 4 4 1 1 2.7 k 2.7 k 5 5 FE FE FE FE IP67 -20No.EX-OMN0035CN-A (2)EX600-DXC 1 24 V() 3 0 V() 4 EX600-DXPC EX600-DXNC 1 24 V 1 24 V *1 DC24 V 3 0 V DC24 V 3 *2 0 V 4 4 2.7 k 2.7 k 1EX600-DXPC1 2EX600-DXNC1 IP67 2 OFF 0.5 mA () OFF 0.5 mA 3 0.5 mA SI -21No.EX-OMN0035CN-A (3)EX600-DXE 1 0 2 2 3 4 4 6 5 8 6 10 7 12 8 14 9 NC 10 24 V()
-10 (INC) c 10[mm] 0 10 20 30 40 50 [mm] -27- 4 a b c d e f g h i j k No. 1 2 mm/s mm mm/s^2 mm/s^2 % % mm/s % mm mm mm 0 ABS 100 20.00 3000 3000 80 40 30 100 10.00 20.00 20.00 No.00[mm] 20[mm]20[mm] 1 10 W [mm] c [mm] k 20 0 10 20 30 40 50 [mm] INP 2 k INPON g 30 W [mm] c [mm] k 20 0 10 20 30 40 50 [mm] INP INPOFF () k g BUSYONOFF -28- 5 a b c d e f g h i j k No. 1 2 mm/
10mm/s LESH8R LESH16R LESH25R J K J K J K 4 6 15 23.5 43 77 7 10.5 25 39 71.5 128.5 [N] 10 15 35 55 100 180 *20%F.S.
Load Switch 1 Load Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Load impedance is 3 k. Leakage current from switch is 1 mA. Power supply Residual Load voltage at ON = voltage voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Example: Power supply is 24 VDC.
PROFIBUS DP V1 9.6 k/19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 M 156 k/625 k/2.5 M /5 M/10 M Communication speed [bps] 10 M/100 M 125 k/250 k/500 k Configuration file Note 2) GSD file EDS file EDS file Communication specifications Input 896 points 108 words 4 stations occupied (8 times setting) Input 57 words Output 57 words Input 256 bytes Output 256 bytes Input 200 bytes
Symbol Material -XC14 Change of trunnion bracket mounting position J 70C Nylon tarpaulin -XC15 Change of tie-rod length Bore size (mm) Cylinder stroke (mm) 110C K Heat resistant tarpaulin -XC18 NPT finish piping port 180 1,569 Maximum ambient temperature for the rod boot itself.
Refer to page 13 regarding the trunnion bracket. 11 Cylinder with Lock Double Acting: Single Rod Series CNG Clevis type (D): With rubber bumper/CNGDN Rc(PT) BP unlocking port Unlocks when pressurized Rc(PT) P Rear cylinder port RR L S + Stroke H GB A F K GA BN GC AL 8-J CZ TT H1 Rc(PT) P CD H10 (hole dia.) MM Front cylinder port d9 (shaft dia.)
Rod Boot Material 125 140 160 Max. ambient temperature Rod boot material Bore size (mm) Symbol J 70C Nylon tarpaulin Foot (1) CS1-L12 CS1-L14 CS1-L16 110C K Heat resistant tarpaulin CS1-FL12 CS1-FL14 CS1-FL16 Rod side flange style (2) Maximum ambient temperature for the rod boot itself.
MOUNTING THREAD W M R C G J Q P K N 2 A Bowl Detail U (AF20) H L E IN OUT D Bracket (Optional) Note: Sight glass not applicable to AF20.
J K J K M J K M N Q R S T N.C., N.O., COM.