Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.
AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B AS Series Speed Controller: Standard Type Elbow Type (Metal Body) Note) The flow rate characteristics are representative values.
VP717 AC40-A Y400-A Y400T-A E400-04-A AN40-04 AN402-04 * Refer to page 3 for details of the spacer. 1 Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve VP500/700 Series Specifications Fluid Air Type of actuation N.C.
"), 250 (2-1/2") RCSK-015 RCSK-02 RCSK-03 RCSK-04 RCSK-05 RCDK-015 RCDK-02 RCDK-03 RCDK-04 RCDK-05 Rod Clevis Pin Applicable bore size Including Kit no.
60 7 70 8 80 9 90 Symbol Valve type Symbol Body material Size 30 40, 50, 60 70, 80, 90 C Brass V V S Stainless steel V V B Bronze V A Aluminum V 2(OUT) 1 N.C. 1(IN) r Seal material t Port size i Electrical entry Symbol Seal material N NBR F FKM E*1 EPDM Symbol Connection Port size Size 30 40 50 60 70 80 90 02 Symbol Electrical entry CE/UKCAcompliant UL Standards 1/4 V 03 3/8 V V 04
(This is not applicable to VHS40) Body Size Symbol Port Size Body Size 20 30 40 02 03 04 1/4 3/8 1/2 Effective area (mm2) 5 5 Model VHS20 VHS30 Note: Other sizes, thread forms, options, etc. may be possible, please contact SMC for availability.
In-line type 04 06 07 4 6 1/4" With exhaust port fitting With One-touch fittings Note) Brass parts are all electroless nickel plated. Caution Be sure to read before handling.
1 O-ring NBR 01 to 04 type !2 Bushing PBT 01 to 04 type !3 O-ring NBR M3 type PVC !4 Gasket M5, U10/32 type NBR, Stainless steel Note 1) AS220 type is electroless nickel plated. Note 2) AS220 type is made of steel.
-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5
Common exhaust: VV3P7-41Stations 1-04 (G) (E) (T) (D, Y) N.C.
-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5
A1 L1 R1 U1 NDH10 U(H8) E1 MM NX Applicable bore size (mm) Applicable bore size (mm) I-02 I-03 I-04 IA-04 Part no.
Symbol Note 1) Drain guide is NPT1/4 (applicable to AW30 to 40) Note 2) Drain guide is G1/4 (applicable to AW30 to 40). 20 30 40 30 40 01 02 03 04 06 1/8 1/4 3/8 1/2 3/4 02 03 04 06 1/4 3/8 1/2 3/4 Option Note 3) Option Note 3) Description With bracket Applicable model AW30, 40 AW30, 40 AW30, 40 Symbol Nil B G Note 4) H Description With bracket Applicable model AW20 to 40 AW20 to 40 AW20
VV5FA1 3 04 31 Individual exhaust (VFA1000 only) Thread type Nil 00F 00N 00T Manifold model Stations 02 Rc G NPT NPTF 2 stations Symbol 31 P, R Port size 1/8 EA, EB Port size M5 20 20 stations Note) When placing an order for body ported valve as a single unit, mounting screws for manifold and gasket are not attached. Order them separately, if necessary.
from the VY Valve. 02 14 2.0 3 03 38 3.3 body Ported Type 04 12 3.9 Terminal Designations are as follows: 04 12 7.2 5 06 34 8.9 1 = 24v Power Supply 2 = Control Signal 3 = Common Negative for both power and signal. 10 1 10 5% 2% + -2% 7 10 1 114 17 12 114 18 9 14 112 2 33 20 2 37 Courtesy of Steven Engineering, Inc. !
-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 VY1 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 G 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 PPA 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 AL 24 28 2 43 48 36 112 100 76
Size 21 31, 41 NPT Threads Port Size Accessories Applicable Body Size 20 30 40 Symbol 02 03 04 Description None Mounting Bracket Float Auto Drain (N.C.)
{Rc1/2} FGH200-04 {Rc1/2} FGH300-04 {Rc1/2} 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) 0.01 0.01 0.01 0.005 0.005 0.005 0.001 10 30 50 70 100 0.001 10 30 50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-06 {Rc3/4} FGH200-06 {Rc3/4} FGH300-06 {Rc3/4} 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Voltage symbol 24V 12V 100V 200V 110V 220V Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC How to use DIN Terminal Caution Connection 1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block. 2.
Size 21 31, 41 NPT Threads Port Size Accessories Applicable Body Size 20 30 40 Symbol 02 03 04 Description None Mounting Bracket Float Auto Drain (N.C.)