SMC Corporation of America
Elite Part Number Search
Search Results "11-LEJS63S3A-1200"

(mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

20 Double Acting Single Acting Double Acting 35, 40, 45, 50, 75, 100 75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 Construction . 6 25 Dimensions . 7 & 8 Reed switch D-A90, A90V D-A93, A93V D-A96, A96V Series CQSW Basic Non-rotating Rod 12 16 5, 10, 15, 20 25, 30 How to Order . 1 Construction . 9 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 12, 16 20, 25 Dimensions ...10 &11

PA + Stroke GB Q G J K IE S XAH7 depth XL (mm) MLGPM, MLGPL common dimensions Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA IB IC ID IE 14 11 100 44 16 12 44 54 10 120 M6 34 52 14 4 14 40 25, 50, 75 100, 125, 150, 175 200, 250, 300, 350 12 13 107 44 20 16 47 64 148 M8 35 64 19 50 11 7 14 115 49 20 16 50 78 162 M10 38 77 19 63 16.5 16.5 13.5 6.5 16.5 Bore size (mm) J

closed Finger closing port 5 0 0.1 4-M2.5 x 0.45 (mounting screw attachment ) 3 Max. 6.1 4-M4 x 0.7 5.7 12 2.5 Depth 6 (two on opposite side) 34 63 22.5 M5 x 0.8 Finger opening port 5 2 11.5 3-R1.5 23 18 11 25 15.5 41.5 4.5 33 Angle adjustment bolt 2-8 Depth of counter bore 2.5 3-R1.5 11 2-4.5 through 2 3-3H9 + 0.025 0 Depth 4 (one each on three sides) 10 3-3H9 long groove depth 3 + 0.025

OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .

(Initial value) Note 3) Value for high pressure type (1.5W) specification Note 4) Value for the low power consumption (0.5W) specification 56 Series VQ1000 VQ1000/Flat Cable Kit Stations VV5Q13J 0(D) U S Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) L2 23.5 P = 11 13.2 L1 6.2 41 35 Indicator light 1.5 1.5 (11) 19.5 (Mounting hole dimension) Manual override 2-

20 26 49 Approx. 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399

] 15 [0.10] 15 [0.10] 7.3 [0.05] 7.3 [0.05] 7.3 [0.05] 0.00 0 1.3 [5] 2.6 [10] 4.0 [15] 5.3 [20] 7.9 [30] 9.2 [35] 11 [40] 12 [45] 6.6 [25] 0.00 0 1.3 [5] 2.6 [10] 4.0 [15] 5.3 [20] 7.9 [30] 9.2 [35] 11 [40] 12 [45] 13 [50] 15 [55] 16 [60] 6.6 [25] 0.00 0 0.1 [0.5] 0.3 [1] 0.4 [1.5] 0.5 [2] 0.8 [3] 0.9 [3.5] 1.1 [4] 1.2 [4.5] 1.3 [5] 0.7 [2.5] Flow rate gal/min [L/min] Flow rate gal/min [

50, 63 44 49.5 49.5 60 60 60 71.5 71.5 17.5 19.5 19.5 20 20 20 22 22 21 24 24 31 31 31 41 41 4.5 5 5 6 6 6 7.5 7.5 7 8 8 11 11 11 14 14 7 8 8 11 11 11 13.5 13.5 13 17 17 22 22 22 27 27 30.5 34 34 38 38 38 44.5 44.5 8 9 9 13 13 13 15 15 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 0.03 0.05 0.05 0.11 0.11 0.11 0.22 0.22 JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125

19 18 35 0.29 0.17 0.18 0.40 0.32 0.40 0.24 0.42 0.13 0.3 0.4 7 3 8 11 15 11 15 14 20 0.6 0.7 1 2 3 4 0.9 1.0 Port size Flow rate characteristics Weight (kg) Orifice dia.

No.EX-OMY0021 PRODUCT NAME SI unit ( device) MODEL / Series / Product Number EX430-SIL1 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Summary of product function 10 Installation and Wiring 11 Installation 11 Wiring 12 LED Indication, Settings and Status Monitoring 13 LED indication 13 Switch setting (Data transmission rate setting

) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I 1 W Z (2 m) (2

Additionally, note that the 12 VDC relay does not apply to the auto switch. -12- 11. Pay attention to leakage current. <2-wire type> Current (leakage current) flows to the load to operate the internal circuit even when in the OFF state.

No.MH*-OMY0005 // MHF2-8D MHF2-12D MHF2-16D MHF2-20D 1. . 4 2 . 5 2-1 . 5 2-2. . 5 2-3 . 6 2-4. . 10 2-5 . 11 2-6. . 11 2-7. . 11 3 . 11 3-1. . 11 3-2. 1 . 12 3-2. 2 . 13 3-3. 1. 14 3-3. 2 . 15 3-4. /1 . 16 3-4. /2 . 17 1 *1) (ISO/IEC) (JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems

/ Refer to JXC controller operation manual. 11) Because the operation of the step data is set to [INC/relative], the table comes into contact with an external object and does not move due to continuous operation.

R . 11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 12 T . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 12.4 . 12-3 12.5 . 12-4 13 V . 13-1 13.1 . 13-1 13.2 . 13-1 13.3 . 13-2 14 . 14-1 14.1 . 14-1 IDFA60/70/80/90 Series IDX-OM-W094 1 1.1 z z z z z z z z z () 6.2 z 1.1.1 3 IDFA60/70/80/90 Series 1-1 IDX-OM-W094 1.2 6 1.2.1 1.2.2 50 1.2.3 0 IDFA60/70/80/90 Series 1-

Function Admin mode Monitor only mode I/O Monitor Available Available Diagnostic status monitor Available Available Parameter setting Available Not available Force I/O setting Available Not available Note This software operates correctly using Internet Explorer 6 to 11.

Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

Wiring 1) Pass them through the cable (7) in the order of cable ground (4), washer (5), rubber seal (6), and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note 1) Tighten within the tightening torque of 0.5 Nm +/-15%.