SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q32-12-00T"

(Refer to page 10 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 l Operating range (see table below) 12.5 Most sensitive position Bore size (mm) Bore size Operating range 12 16 20 25 32 40 50 63 80 100 Operating range l (mm) 7.5 10 10 10 10.5 10.5 10.5 11.5 11.5 12 Note) This is a standard including hysteresis, and is not guaranteed.

(Refer to page 10 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 l Operating range (see table below) 12.5 Most sensitive position Bore size (mm) Bore size Operating range 12 16 20 25 32 40 50 63 80 100 Operating range l (mm) 7.5 10 10 10 10.5 10.5 10.5 11.5 11.5 12 Note) This is a standard including hysteresis, and is not guaranteed.

Joints 12 7 25 9 34 11.5, depth 7.5 YB-03 32, 40 K ( across flats) 12 9 32 11 42 14.5, depth 8.5 YB-05 50, 63 H (with locking) 16 11 38 13 52 18, depth 12 YB-08 80 d2 d1 19 14 50 17 62 21, depth 14 YB-10 100 L UT Weight (g) Bore size (mm) C UA RS W T1 T2 V Part no. (mm) 9 50 18 6.5 10 YB-03 32, 40 80 UA C d1 d2 H K L UT Weight (g) Part no.

KBV3-12 12 KBV4-12 KBV4-16 Part No. Rc(PT) 1 4 KBZ1-04 KBZ1-06 4 6 KBZ2-08 8 KBZ3-10 10 KBZ3-12 12 KBZ4-12 Rc(PT) 3 8 16 Bulkhead female connector: KBE Female connector union: KBH T Connecting thread Applicable tube O.D. Part No. Part No.

long strokes Bracket mounting strokes Stroke range (mm) Bore size (mm) Bore size (mm) Bracket mounting stroke Bore size (mm) P Y Z Y X T W S V R Q R U 20 25 32 40 50 20 25 32 40 50 20 25 32 40 50 Rc 1/8 100mm or more 88 250 to 400 157 80 30 40 12 26 48 12 21 14 82 Rc 1/8 125mm or more 88 350 to 500 175 80 37 13 46 57 31 12 21 14 100 Rc 1/8 150mm or more 90 350 to 600 201 82 37 52 16 38 65

SY7000 3 8" N11 N9 N11 5 16" SY9000 3 8" Electrical entry Grommet L plug connector 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/ 100, 110, 200, 220 VAC M plug connector DIN terminal Manual override Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type G:Lead wire length 300 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm

) 10 m or less CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power supply CN3 (Note 12) (Note 2) (Note 17) Electromagnetic brake interlock 13 MBR (Note 3, 4) Forced stop 2 RA1 20 EM2 (Note 13) 9 INP In-position RA2 FLS DI1 2 15 ALM Malfunction (Note 11) (Note 14) RLS DI2 12 RA3 DOG DI3 19 5 DICOM Encoder A-phase pulse (differential line driver) 6 LA (Note 10) 24 V DC 16

Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I

Refer to the attachment table on page 14-2-12 or 14-2-16 for standard bypass port sizes applicable to AC.

to 50mm/s) i2 to 100 Heal resislant aulo swilch 16 to 63 Hea\./ duty sctaper 20 to 100 Stalnless steelpiston rod and rod nut 12 10 100 AdjuslaLle stroke exlend 12 to 100 Adjustable slroke retract 1 2 l o 1 0 0 DualsLroke, dual rod 1 2 b 1 m DLralstroke s ngle rod 12 to 100 NPI Porr (1) 32 10 160 32 lo 100 Wilh lrcnr gulde boss (1) 12 to lO0 20 to 10O lnch-sizewrcnch flab 12 to 100 (1) Not

17 26 40 56.2 7 12 8 24 21 41 16 13.5 12.5 50 14 22 32 Note) For 32, a trunnion pivot bracket NA (42.5) is used as standard.

AK Flow Rate and Sonic Conductance VCHC ASR ASQ Model AS22l1F-U01 AS23l1F-U01 AS22l1F-U02 AS23l1F-U02 AS32l1F AS33l1F AS42l1F AS43l1F Flow Direction Symbols on Body Meter-out Meter-in Metric size 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Symbol Tubing O.D.

17 26 40 56.2 7 12 8 24 21 41 16 13.5 12.5 50 14 22 32 Note) For 32, a trunnion pivot bracket NA (42.5) is used as standard.

V CY1H 12 V Solid state auto switch Reed auto switch Yes IC circuit CY1F CY1F 5 V, 12 V Relay, PLC Diagnostic indication (2-color indicator) Grommet 24 V 12 V CYP IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V IC circuit 3-wire (NPN equivalent) A96V A96 5 V 12 V Yes 24 V Grommet Relay, PLC A93V2 A93 A90 100 V 2-wire A90V IC circuit No 100

V IC circuit 12 V 5 V, 12 V IC circuit Relay, PLC Diagnostic indication (2-color indicator) 24 V Yes Grommet 12 V 5 V,12 V 12 V IC circuit Water resistant (2-color indicator) 3-wire (NPN equivalent) Grommet 24 V Reed auto switch A96V A96 IC circuit 5 V Yes A93V2 A90V A93 A90 100 V IC circuit Relay, PLC 2-wire 12 V No 100 V or less 1 Water resistant type auto switches can be mounted

SGH Ex. 2) 3 port valve: Switching nozzle 12 VNC VNH Port 12(P1) (Pilot air SUP port) Nozzle Port 12(P1) (Pilot air SUP port) 3 1 2 VNH VNH Tank Coolant pump VND Switching nozzles on supplying coolant liquid.

12 12 12 12 11 10 13 16 11.5 15 9 13 13 13 14 14 9.5 9.5 9.5 17 11.5 D-A79W D-A9, A9V D-F7, F7V D-J79, J79C, J79W D-F7W, F7WV D-F79F, F7BAL D-F7BAVL 5.5 5 6 6 6 6.5 6.5 7 7 7 8 7 8 8.5 8 9 D-F7LF D-F9, F9V D-F9W, F9WV D-F9BAL 5.5 5.5 5.5 6.5 5.5 6.5 Hysteresis specifications are given as a guide, it is not a guaranteed range.

V PLC Terminal conduit 24 V 2-wire 100 V, 200 V DIN terminal Grommet Relay, PLC Diagnostic indication (2-color indication) 3-wire (NPN) IC circuit 24 V 5 V, 12 V 3-wire (PNP) Grommet 100 V, 200 V 12 V 5 V, 12 V 12 V 2-wire 3-wire (NPN) IC circuit Terminal conduit Relay, PLC 2-wire 3-wire (NPN) 3-wire (PNP) IC circuit 24 V Diagnostic indication (2-color indication) 5 V, 12 V Grommet

M Weight (g) AS AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 7.8 8.9 11.0 15.2 18.5 8.9 11.0 15.2 18.5 11.0 15.2 18.5 20.9

ON/OFF / / 2 2 3 3 1 2 / 11 - 5.3 [] (LEC ) (LEC ) / P.42 7.3 <> (NPNPNP) LEHZ10K2-4 NPN <> INP(IN ) INP ON ON INP ON OFF ) P.50,P.52 8.3 12 - <> No.0 a b c d e f g h i j k a ABSINC ABS() / / INC()// b c ) / P.50 8.3 d e f 0(0 ) g h i )150%/ P.52 8.3 j 12 AREA ON 121 INC ABS() )No.0 120 222 AREA 13 - k INP(IN )ON INP INP ON )0.50 )No.0 22 10 12 INP 14 -