LED flashes when the station number or communication speed settings have changed during communication (the L RUN LED will turn on and the SI unit will operate according to the new settings once power is restored). L ERR.
G Rear flange F Front flange L Foot C Male rear clevis D Female rear clevis 1.8-29
L (Ex.) A53L 5m . Z (Ex.)
B + Stroke A + Stroke 93.5 75.5 83.5 65.5 6.6 9 67 76 89 50 95 77 89 71 9 9 80 92 108 63 Rod end male threads Bore size (mm) L L1 M 32 17 38.5 34 40 17 38.5 40 50 18 43.5 50 63 Rod end nut L1 18 43.5 60 Rear flange type/CBQ2G, CDBQ2G (mm) Rear flange type With rear lock With front lock Bore size (mm) L L1 A A FV M 80.5 73 7 28.5 32 90 79.5 7 28.5 40 4-FD FT L 92.5 82.5 8 33.5 50 B + Stroke
A K = 1 L A L A End plate mounting Mp Mr W My W W W L A W L A L A K = 0.6 W Mey Mep L A A L Note 1) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with stopper Max. allowable load weight: Wmax(kg) Allowable kinetic energy: Emax (J) Table 1 Table 2 Allowable load weight coefficient: Graph 1 Model Allowable kinetic energy Adjuster option
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without an unit switching function.)
Controller side PLC side For 4 Axes JXC73/83 L JXC C2 (Terminal no.) (R1.25-4) 40 20 39 (7.5) 40 20 Cable length (L) [m] 50.8 1 1.5 3 3 5 5 2 21 1 21 1 Pin no. Wire color Pin no. Wire color Pin no. Wire color Pin no.
AS2002F-04 When connecting 4 pcs. and mounting L-brackets on both sides Speed controller AS2002F-04 4 pcs. L-bracket AS-20L 2 pcs.
As the flow rate when Kv = 1 is calculated as the formula: Q0 = 15 x 1/1.5 = 10 [L/min], read off P when Q0 is 10 [L/min] in Graph (2). The reading is 0.036 [MPa]. Example 2) Obtain the saturated steam flow rate when P1 = 0.8 [MPa] and P = 0.008 [MPa] with a solenoid valve with a Kv = 0.05 [m3/h]. Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h.
[P] Set value of OUT 1500 L/min 3000 L/min 6000 L/min S button (SET) Press this button to change the mode and to set a value. [H] Hysteresis of OUT 150 L/min 300 L/min 600 L/min Connector pin numbers (lead wire) Specifications / Dimensions button (DOWN) Selects the mode and the display shown on the Sub display, or decreases the switch point.
s t o p p e r I n s t a l l p o s i t i o n o f e x t e r n a l s t o p p e r C auti on on usi ng exte rnal stoppe r R o t a r y a c t u a t o r w i t h A u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s e t p o s i t i o n I n t e r n a l s t r u c t u r e a n d o p e r a t i o n p r i n c i p l
Guide rod type / LEYG Series 3.1 Specification Model LEYG25M L (Top/Parallel) / L D (In-line) LEYG32 M L (Top/Parallel) LEYG32 M L D (In-line) LEYG25 M Horizontal Note 1) 18 50 50 30 60 60 30 60 60 Work load [kg] Vertica 7 15 29 7 17 35 10 22 44 Force [N] Note2) (Set value LEY25S/32S15 to 30%) (Set value LEY25T/32T12 to 24%) 65131 127255 242485 79157 154308 294588 98197 192385 368736 Actuator
Bore size 20, 25/MLGPM20/25 (Slide bearing) Operating Range as Stopper for MLGPM20/25 100 25 l = 50 mm l = 50 mm Weight of transferred object: m (kg) m m 20 5 10 10 20 30 40 50 Transfer speed: (m/min) Bore size 32 to 100/MLGPM32 to 100 (Slide bearing) Operating Range as Stopper for MLGPM32 to 100 1000 Weight of transferred object: m (kg) l = 50 mm l = 50 mm 100 m m 80 63 50 40 32 100
Max. flow capacity L/min (ANR) 3F 4 30 4G 6 65 5H 8 130 7J 10 200 Plug-in type Bracket SFE-BR 3 Symbol Applicable model 3 SFE3l 4 SFE4l 5 SFE5l 7 SFE7l One-touch fitting type Specifications Model SFE11 SFE3 SFE4 SFE5 SFE7 Fluid Note 1) Air Maximum flow capacity Note 2) Up to 3 L/min (ANR) Up to 30 L/min (ANR) Up to 65 L/min (ANR) Up to 130 L/min (ANR) Up to 200 L/min (ANR) Filtration rating
Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
Part No. 1 3 to 90 N X 8 31 TCU0425l -1-N-X6 L X 5.9 + 200 L X 5.2 + 200 1 3 to 90 N X 4 18 TCU0805l-1-N-X6 8 5 TCU0425l -2-N-X6 42 N X 8 L X 4.4 + 200 L X 3 + 200 2 3 to 90 N X 16 2 3 to 40 28 4 2.5 TCU0805l-2-N-X6 TCU0425l -3-N-X6 52 N X 12 3 3 to 63 L X 2.9 + 200 1 3 to 45 L X 5 + 200 N X 10 28 TCU1065l-1-N-X6 10 6.5 L X 5.3 + 200 L X 3 + 200 N X 6 24 1 3 to 90 52 2 3 to 35 N X 20 TCU0604l
Symbol x 50 001 005 010 020 050 075 100 002 004 006 013 q q w w 0.01 0.01 e r e 0.005 0.005 r 0.002 5 10 50 100 0.002 10 50 100 Flow rate l/min (ANR) Flow rate l/min (ANR) Note) The recommended flow rate is the rate for an initial pressure drop of 0.01 to 0.02 MPa. 2 Series FQ1 How to Order Filters Element and Seal Part Numbers 1.