AL10/20 AL30/40/40-06 AL50/60 Body Zinc die-casted Aluminum die-casted q i Platinum silver Platinum silver Housing Aluminum die-casted Replacement Parts Part no. Material Description No.

Modular Type Lubricators Series AL AC-A Lubricator Series AL Model AF-A Port size Option AF-A AL10 M5 x 0.8 AR-A AL20 1/8, 1/4 AL-A AL30 1/4, 3/8 AW-A AL40 1/4, 3/8, 1/2 Bracket AC AL40-06 3/4 AF AL50 3/4, 1 AF AL60 1 Pages 508 through to 513 AR AL AL AW AG E AV AF 507 Lubricator AL10 to AL60 Symbol Lubricator AL20 AL40 How to Order AL 30 03 B Option/Semi-standard: Select one each for a

ZFC201-07 ZFC100-06 ZFC101-07 Cover Element (Replaceable) 0.1 1 10 100 Flow rate (l/min (ANR)) Bracket Replacement Parts Description Part no.

Universal type (throttle valve) 10-AS2301F-01-06-X214 10-AS1301F-M5-06-X214 10-AS2301F-01-06-X214 1.

Wiring Caution To prevent damage, all voltages to the SI Unit must be turned off (i.e. de-energized) before the modules are installed or removed. Wire the grounding cable, the PROFINET cables and the power cable.

zgodnoci UE Declarao UE de conformidade Declaraia de conformitate ue Vyhlsenie o zhode E Izjava EU o skladnosti EU-frskran om verensstmmelse SMC Corporation, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN, declares under its sole responsibility, that the following equipment: Thermo Chiller HRLE Series Serial No.

Displayed for option DM (Electric conductivity control type, de-ionized water piping type) only. The DI solenoid valve can open or close while the operation is stopped. Press [ENT] key to set the DI solenoid valve when the operation is stopped. When the display is flashing, press [], [] key and select YES. Then, press ENT key.

Wiring Caution To prevent damage, all voltages to the SI Unit must be turned off (i.e. de-energized) before the modules are installed or removed. Wire the grounding cable, the PROFINET cables and the power cable.

Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who de necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product.

M5 x 0.8 2-7.5 +0.1 0 Close: 0 Finger opening port DE-E Open: 321 2058 4-M5 x 0.8 thread depth 5.5 8-M4 x 0.7 thread depth 4 Attachment mounting thread Mounting thread 20 43 Auto Switch Mounting Groove Dimensions 2-3H9 +0.025 0 depth 3 2.2 18 5.5 18 5.5 4 4.6 3 2-M5 x 0.8 thread depth 5.5 Mounting thread Groove for auto switch mounting 20 74 12-3-19 20 Series MHF2 Dimensions MHF2-16D2 4H9

M5 x 0.8 2-7.5 +0.1 0 Close: 0 Finger opening port DE-E Open: 321 2058 4-M5 x 0.8 thread depth 5.5 8-M4 x 0.7 thread depth 4 Attachment mounting thread Mounting thread 20 43 Auto Switch Mounting Groove Dimensions 2-3H9 +0.025 0 depth 3 2.2 18 5.5 18 5.5 4 4.6 3 2-M5 x 0.8 thread depth 5.5 Mounting thread Groove for auto switch mounting 20 74 12-3-19 20 Series MHF2 Dimensions MHF2-16D2 4H9

M5 x 0.8 2-7.5 +0.1 0 Close: 0 Finger opening port DE-E Open: 321 2058 4-M5 x 0.8 thread depth 5.5 8-M4 x 0.7 thread depth 4 Attachment mounting thread Mounting thread 20 43 Auto Switch Mounting Groove Dimensions 2-3H9 +0.025 0 depth 3 2.2 18 5.5 18 5.5 4 4.6 3 2-M5 x 0.8 thread depth 5.5 Mounting thread Groove for auto switch mounting 20 74 12-3-19 20 Series MHF2 Dimensions MHF2-16D2 4H9

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

) 300m/s2 in X, Y, Z directions, 3 times each (de-energized) 3% F.S. or less (based on 25C) 4.8 (4.4 in the end) resin piping (applicable to I.D. 4 air tubing) Resin pipe: Nylon, Piston area of sensor: Silicon Accuracy (ambient temperature of 25C) Linearity Repeatability Indication light Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance

Note 2) Vibration resistance: No malfunction resulted in a one-sweep test in a 10 to 300 Hz range in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Shock resistance: No malfunction resulted in an impact test using a drop impact tester.

) 500 m/s2 in X, Y, Z directions, 3 times each (De-energized) Impact resistance Temperature characteristics 2% F.S. or less (0 to 50C, based on 25C), 3% F.S. or less (10 to 60C, based on 25C) Piping Specifications Model 01 02 N01 N02 C01 A2 B2 R 1/8 R 1/4 NPT 1/8 NPT 1/4 Port size M5 x 0.8 Rc 1/8 URJ 1/4 TSJ 1/4 M5 x 0.8 M5 x 0.8 M5 x 0.8 Case: C3604 + nickel plated, Piping port/pressure

) 300 m/s2 in X, Y, Z directions, 3 times each (De-energized) 3% F .S. or less (Based on 25C) 4.8 (4.4 in the end) resin piping (Applicable to I.D. 4 air tubing) Resin pipe: Nylon, Piston area of sensor: Silicon Environmental resistance Vibration resistance Impact resistance Temperature characteristics Port size Material of wetted parts Sensor cable With sensor cable Without sensor cable

Please consult SMC if valves will be continuously energized for extended periods of time or the energized period per day will be longer than the de-energized period. It is also possible to shorten the energization period by using valves of the N.O. (normally open) type.