Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted Type,
Valve Type: Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 150°C, with 80°C at 100VAC, 100°C at 200VAC Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment
Valve Type: Normally Closed, Bellows Seal, Flange Size: 80, Flange Type: D [K(DN)], Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External
Valve Type: Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External
Valve Type: Normally Closed, Bellows Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator
Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, with 120°C Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: 2-
Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, with 120°C Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: 2-
40, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 150°C, No Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: X, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: 2-
for 120℃), Switch Part Number: No auto-switch (no magnet), Number Of Switches: -, Seal Material: Kalrez (Formula No.: 4079), Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: Valve seal 1 / valve seal 2 / external seal, Length of Lead Wire for Switch(m): -