Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-
Request message to write (from master) 02 31 30 57 53 56 31 30 30 32 30 30 03 51 Address BCC data End code Start code Request to write Numerical data Identification code Response message from the product 02 31 30 06 03 06 Affirmation code Start code Address End code BCC data Code Symbol/Data ASCII code Start code STX 02H Address 10 31H 30H Required content W (write) 57H Identifier SV1
N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119
Thread Rc G NPT Nil None Port size 06 3/4" 10 1" A Yes 8 B 5/16" For internal pilot, the symbol is nil. Refer to Piping for External Pilot Type on page 20 for selection of the check valve. Made to Order Series Compatible with Secondary Batteries 1 For details about 25A-, refer to the WEB catalog Series Compatible with Secondary Batteries/Series 25A-.
Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
ASCII code 5 characters Refer to 5.12.11 Communication example. | 0062h 10 decimal number 0 to 4294967295 16 hexadecimal number 0h to Fh 4 bytes 0063h upper level 0064h lower level 0064h 0063h Control board Program No. 10 decimal number 0 to 65535 16 hexadecimal number 0h to Fh 0065h Control board R Program version 10 decimal number 0 to 4294967295 16 hexadecimal number 0h to Fh 4 bytes 0063h
R ZZM 06 06 R Multi-ejecter Common SUP port location Port and silencer location Series ZM Manifold Nil Both sides Number of stations R Right side L Left side B Both sides Right side Left side R L 01 1 station Right or left to the VAC port Right or left to the VAC port 05 5 stations Common EXH port size 10 10 stations (Max.) 04 06 1 2 3 4 Thread type S Silencer for ZZM (ZZM-SA) Nil Rc NPTF
N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6 Paddle Style Flow Switch Series IF3 Fluid and Ambient Temperature Range Enclosure Open type Using indoors away from water drop.
) 12 (18) 13 14 15 1-2. 16 17 FGD-KT001 FGDC 1 FGD-KT002 FGDE (1)(2)(3)(4) (FGD*B2 ) FGD-KT003 FGDT FGD-KT004 FGDF FGD-CV005-03 FGDTF*-03 FGD-CV005-04 FGDTF*-04 FGD-CV005-06 FGDTF*-06 (5) FGD-CV006-03 FGDCE*-03 FGD-CV006-04 FGDCE*-04 FGD-CV006-06 FGDCE*-06 FGD-OP001 FGD*B (10) KT-FGDC FGDC KT-FGDE FGDE (2)(4)(6)(13)(16) KT-FGDT FGDT KT-FGDF FGDF FGD-CA002 FGDT,F(L250) (7)(9)(11)(12)(
Symbol Size 04 4 06 6 08 8 10 10 12 12 16 16 3
VBA VBAT AP100 841 VEX13 Series 0 3 Specifications VEX1A33 VEX1B33 VEX113 0 3 VEX123 0 3 VEX133 0 3 VEX153 0 3 VEX173 0 3 VEX193 0 3 Model Port 1(P) 2(A) 3(R) M5 01 M5 01 01 02 01 02 03 02 04 04 06 10 12 14 10 20 1 8 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 2 1 1 1 1 1 Port size M5 M5 1 2 4 1 4 1 2 Operation Manual knob (Push locking slotted type) and Air operated type Manual knob (Push locking
Series SV2000 for EX120 Dedicated Output Serial Wiring. 6 7 8 10 10 10 10 10 10 10 11 11 11 11 11 11 12 12 13 13 13 15 16 16 17 19 20 21 21 23 23 24 24 24 24 24 25 26 27 27 30 30 31 32 33 34 35 36 37 37 39 40 40 41 42 44 45 45 50 50 51 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
06 3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.
Mtrual opralor assmbly $llh Odng PA0@1 PBO{01 I 1 Raplacdr3nl coll only-4.C. sol6nold 1Al0 aot@ 1O/@ cl2A{9 cl2A-10 cl2A.1t 10 I Sol6noi, aBsmbly-4,C. conplst wllh coll, 120/ao 24(m0 a0,t0 @14O9 @ta-10 cora-1t At2A{9 412A,10 1 l '| NXT01010 NXT0307.3 12 1 NXTO1G12 NXTO1G12 13 @t|vo scr6w .nd locl wa5hsr xTt)10-21 xT010.21 DIRECTIONAL AIR YALVE MANIFOLD ASSEMBLY SERIES NVS 3115, 3125 NVS 3135
Fluoropolymer Needle Valve Series LVN Specifications LVN20 LVN30 LVN40 Model Orifice diameter 4.4 4, 6 1/8", 3/16", 1/4" Metric Inch 10 10, 12 3/8", 1/2" 8 6, 8, 10 1/4", 3/8" Tube size Refer to Best Pneumatics No. 7 for further details.
II Air Cylinder Drive Systems Total Stroke Time and Speed at the End Series SV Series SV1000 Applicable bore size: 20, 25, 32, 40 Applicable related components Total stroke time s Solenoid valve Tubing Speed controller Silencer 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 50% 70% 10% 30% 150 Stroke mm AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 200 CM2 25 150 Stroke mm AS2201F
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15
ZF ZP ZCU How to Order Ejector Manifold AMJ ZZMA 06 06 R Misc. Number of stations Port and silencer location R L B 01 1 station Right side Left side Both sides 10 10 stations (max.) Note) Right and left side are viewed from the front side of VAC port.