mA AD AD PLC PLC (AD ) (0b) (AD ) (ab) [V] [mA] [V] [mA] 10 10 15 420 010 05 020 4095 5.25 21 4095 10.5 5.25 21 3868 5 20 3901 10 5 20 2048 3 12 2048 5.25 2.625 10.5 228 1 4 0 0 0 0 0 0.75 3 : 010 V 10 VPLC 3901 -48No.EX-OMQ0015CN (2) & 2 : 010 V,05 V,020 mA : 15 V,420 mA AD AD PLC PLC (AD ) (0b) (AD ) (ab) [V] [mA] [V] [mA] 10 10 15 420 010 05 020 2047 5.25 21 2047
10 H 0 10 20 30 40 50 0 10 20 30 40 50 Gripping point L Gripping point L mm Gripping point L mm MRHQ16 MRHQ16 Internal gripping 60 60 50 50 Pressure 0.2MPa Pressure 0.2MPa 40 40 Overhang H mm Overhang H mm 0.3MPa 0.3MPa 0.3MPa 0.3MPa 30 30 0.4MPa 0.4MPa 0.4MPa 0.4MPa 0.5MPa 0.5MPa 0.5MPa 0.5MPa 20 20 0.6MPa 0.6MPa 10 10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping
Single wiring 5 6 7 8 9 10 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 1 2 3 4 5 6 7 8 9 10 1 2 3 4 NEW CONCEPT N.C. valve N.C. valve N.C. valve N.O. valve N.O. valve N.O. valve 5 6 7 8 9 10 1 2 3 4 R2 B R1 A P IP65 enclosure compliant kit (Lead wire) M 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 (R1) 3 (R2) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 2 3 4 4 (A) 2 (B) 4 (A) 2 (B) 4 (A
.Communication setting screen 36.Contact output 46 Setting screen 10.
(mm) E1 R W MF ZF FB CD EB L XD UB CB EW MR TR AO AT XA SA AH AB TF UF E2 32 32 16 10 130 10 12 142 26 48 7 65 45 26 32 10 4.5 144 142 32 9.5 7 64 79 50 40 36 20 10 145 12 15 160 28 55 9 75 52 28 36 11 4.5 163 161 36 12 10 72 90 55 50 45 25 12 155 12 15 170 32 68 9 80 60 32 45 12 5.5 175 170 45 12 10 90 110 70 40 50 12 5.5 190 185 50 63 50 25 12 170 16 20 190 40 80 9 90 70 16 10 100 120
5 6.5 45 15 9 18 21 51 4.3 4 32 16 25 75 12 56.5 80 5 10 45 18 11 22 25 65 4.3 4 36 20 30 95 16 72 100 5 10 55 18 11 22 41 20 32 115 25 75 6.3 16 89 4 Mounting style (ES) Bore size (mm) d3 CN S5 K1 K2 I2 G1 G2 G3 EN EU CH H6 ER 32 11 10 38 51 21 18 31 14 32 10 15 10.5 8.5 6.6 40 11 12 41 54 24 22 35 16 36 10 18 12 8.5 6.6 50 15 16 50 65 33 30 45 21 45 12 20 15 10.5 9 63 15 16 52 67 37 35
P.5-10 It indicates the set temperature. (10) Circulating fluid set temperature P.5-10 CH2 Press the numeric section to change the set temperature. (11) Circulating fluid discharge pressure It indicates the discharge pressure.
160 200 Flow Rate (slpm, N2) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) AK1400TA Inlet pressure: 0 psig (14 kPa) 760 0 -8 700 Delivery pressure (mm Hg abs) -21 600 Delivery pressure (kPa) -35 500 -48 400 -61 300 -75 200 -88 100 -101 0 0 1 2 3 4 5 6 7 8 9 10 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.
Enable Val165000 4 ON 8 ON/OFF 3 Disable ON/OFF 0 83 9 ON/OFF Auto 10 HDX 10 BUS IN BUS IN 10 FDX 100 HDX 100 FDX Auto 10 HDX 11 BUS OUT BUS OUT 10 FDX 100 HDX 100 FDX 1Hold/Clear Via software 2PLC 330 4x1000 -44No.EX-OMS0026CN No.
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Number of auto switches mounted Bore size (mm) 32 1, 40 50 2, 63 1 10 5 15 15 10 10 2 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 7 Prior to Use Auto Switches Common Specifications
UPPER AND LOWER LIMIT ARISES -9-2 FIG. 10-1 MOISTURE AIR DIAGRAM -10-3 vi Contents Table List Page No.
M 10 M IDU8E/11E/15E1-10/20 10-1 ( ) IDU Series 10-1 10 1 IDX-OM-W023 10 M 10-2 ADM200 IDU8E15E1-10-M IDU8E15E1-20-M IDF-S0087 IDF-S0090 1.0MPa 1 1 2 / AC100V(50/60Hz) AC200V(50/60Hz) 4W (R1/2) (Rc3/8) Rc1/2 26 Rc1/2 IDU Series 10-2 10 2 IDX-OM-W023 10 M 10-3 Rc1/2 32 25 1) 2830Nm 30 (5) (17)(30) 2 2 Rc1/2 10-4 1-1 IDU Series 10-3 10 3 IDX-OM-W023 11 R
MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 2 Series MXQ Theoretical Output IN OUT Application of the dual rod system generates double the output of conventional cylinders.
10 10 54 32 26 11 22 20 44 16 11 15 6 27 71.5 60 42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13
Refer to LECSS2-T Operation Manual,section 3.5 for input/output signal details. -10- 3.3.2 Source Sink I/O interfaces Connection example An example wiring diagram for Sink I/O is shown below Driver Servo amplifier () CN8 (Note 16) Short-circuit connector (Packed with the servo amplifier) 10 m or less driver) (Note 12) CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power
10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
PA06 1 100 35 100 (10) (7) (10) Electronic gear denominator *3.
49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51 10 18 14 15 7 47 6.6 63 1/4 19.5 10 40 M16 x 2 14 depth 8.6 65 55 10 22.4 19 20 7 52 9 71 1/4 20.5 10 50 M20 x 2.5 17.5 depth 10.8 71 60 11 28 24 24 8 58 11 81 1/4 22 10 63 M27 x 3 20 depth 13 80 67 13 35.5 30 33 9 69 13 97 1/4 25.5 10 80 M30 x 3.5 23 depth 15.2 95 78 17 45 41 36 14 86 15 117 3/8 30 15 100 M39 x 4 26 depth 17.5 122 96 26 56 50
EDS Enable 1 (SC_MonSs) Disable -10..10 V -5..5 V -20..20 mA 0..10 V 2 (Range) -10.. 10 V 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary PLC 3 (D_Format) Sign & Magnitude 2S Complement 2 None 2 2AVG 2 4 (Filter) 4AVG 4 8AVG 8 Enable 0.5 5 (Over_Rng) Disable Enable 0.5 6 (Undr_Rng) Disable 1 Enable (Upr_Lmt) 2 7 Disable 1 Enable (Lwr_Lmt) 2 8 Disable 1 2DeviceNet