7.4 -80N 55.4 59.1 68.3 7.8 8.5/12.5 -85N 19 17.4 36.6 105.1 7.4 8/12 KK6S-80N 66 71.3 31.2 41.2 24 107.8 7.8 8.5/12.5 -85N 1/2 24 64.4 20.1 69.7 68.4 117.4 10.2 11/16 -110N 7 S Couplers Series KK Straight type with One-touch fitting Applicable tubing D1 D M L L (mm) Effective area mm Urethane tubing Nylon tubing L D D Min. bore M Applicable tubing O.D. mm L When connected Body size Weight
Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-5L 5-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 Piping adapter ZS-46-N1 NPT1/8 Piping adapter ZS-46-N2 11 3-Screen Display High-Precision Digital Pressure Switch ZSE20A(F)/ISE20A
D-F7lW D-F7lF D-J79W D-F7lWV D-A7lH, A80H D-A73C, A80C D-F7l, J79 D-F7lV, J79C D-F9lW D-F9lWV D-F9BAL D-P5DW D-A9l D-A9lV D-F9l D-F9lV D-A7, A8 D-A79W Model A 28.5 29 32.5 23.5 28 28.5 A 34.5 25.5 30 30.5 B 6 6.5 10.5 13.5 16.5 19.5 B 12.5 15.5 18.5 21.5 A 29 29.5 33 24 28.5 29 B 6.5 7 11 14 17 20 A 26 26.5 30 21 25.5 26 B 3.5 4 8 11 14 17 A 33 33.5 37 28 32.5 33 B 10.5 11 15 18 21 24
D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-P3DW 13 11 11.5 10.5 11 12 D17 7 14.5 6 15.5 5.5 14 6 14 15.5 -X 397 MK Series Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height D-F79F/F7NT D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV B A U 20, 25 20, 25 U B A 32
D-F9N D-F9P D-F9B D-F9G D-F9H N.C. (B contact) N.O. (A contact) Contact Electrical entry In-line Wiring type 3 wire 3 wire 2 wire Output type PNP NPN NPN PNP 24VDC relay, PLC IC circuit, Relay, PLC IC circuit, Relay, PLC Applicable load Auto switch internal circuits Lead wire colors inside [ ] are those prior to conformity with IEC standards.
0 (15) 25 D-M9, D-M9V 15 (17) 0 0 40 50 (57) 32 47 (49) 10 (17) D-F9W, D-F9WV 15 (17) 0 0 40 50 (57) 32 47 (49) 10 (17) D-A9, D-A9V 0 (15) 0 0 50 50 (61) 38 38 (53) 0 (11) 32 D-M9, D-M9V 10 (17) 0 0 50 55 (63) 38 48 (55) 5 (13) D-F9W, D-F9WV 10 (17) 0 0 50 55 (63) 38 48 (55) 5 (13) D-A9, D-A9V 0 (15) 0 0 54 54 (64) 48 48 (63) 0 (10) 40 D-M9, D-M9V 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12)
55) 26 56 (63) 0 0 (17) D-A9, D-A9V 0 (15) 0 40 40 (55) 32 32 (47) 0 0 (15) 25 D-M9,D-M9V D-M9W, D-M9WV 40 (42) 0 40 50 (57) 47 72 (74) 15 10 (17) D-A9, D-A9V 0 (15) 0 50 50 (61) 38 38 (53) 0 0 (11) 32 D-M9, D-M9V D-M9W, D-M9WV 10 (17) 0 50 55 (63) 38 48 (55) 0 5 (13) D-A9, D-A9V 0 (15) 0 54 54 (64) 48 48 (63) 0 0 (10) 40 D-M9, D-M9V D-M9W, D-M9WV 15 (22) 0 54 59 (66) 48 63 (70) 0 5 (12)
Note 3) ( ) in column W denotes the dimensions of D-A93. Operating Range Bore size (mm) Auto switch model 6 10 16 20 5 6 9 11 D-F9W/F9WV D-M9/M9V D-A9/A9V 3 (2) 3.5 (2) 5.5 (3) 6.5 (3.5) Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)
Enter in order starting from the first station on the D side.
Basic type Front ported D-F9 Side ported With external stopper D-M9 11-6-3 4 Series CRJ Precautions Be sure to read before handling.
Basic type Front ported D-F9 Side ported With external stopper D-M9 11-6-3 4 Series CRJ Precautions Be sure to read before handling.
Air leaks. -18- 11. Dimensions 11-1. PRESSURE SWITCHIS10M-20-D to IS10M-60-D Model IS10M-20-D IS10M-30-D IS10M-40-D IS10M-50-D IS10M-60-D A B C D 28 77.6 60.1 42 31 85.6 64.1 53 39 93.6 68.1 71 47 96.6 69.6 71 62 106.6 74.6 90 11-2.
HRZ Series 5.3 Operation Screen 5-11 5-11 HRX-OM-X010 Chapter 5 System Operation Unit of PUMP SP can be selected on Initial Setting screen 1.
(Equivalent tightening torque: T) B Max. = C D 18.8 13.8 11.8 5.8 2.8 0.5 8.6 Width across flats 14 Tightening torque: Tighten within 10 1 Nm. 11 G1/4 (mm) Part no.
and Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) SMC D-A90 B 11 12 A 16 17 B 15 16 A 15 16 B 14 15 A 12 13 SMC D-A90 20 25 A Approx.
HRR Series 3.1 Precautions wiring communication 3-1 HRX-OM-W004 Chapter 3 Serial communication 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
A A B D B D Dimensions Dimensions Dimensions (mm) (mm) (mm) A B C D E F Y A B C D E F G Y A B C D E F Y Model Model Model ZP40HB ZP63HB ZP100HB 40 41.4 28.4 43.2 20.5 30 13 63 65.1 45.5 67.6 31.5 50 4.5 21.5 100 103.1 68.6 106.7 47.5 80 35.5 ZP50HB ZP80HB ZP125HB 50 51.9 35.7 54 24 40.5 16.5 80 83 58.4 85.1 37 64 5 27.5 125 128.5 88.6 135 56 44 105 13-11-95 Series ZPT/ZPR Replacement Parts
Note 4) When specifying more than one option, indicate them alphabetically. 2.10-11 VQZ100/200/300 Body Ported How to Order Manifold VQZ200/300 VV3QZ 2 2 08 C D Series DIN rail mount 2 3 VQZ200 VQZ300 None DIN rail mounting (DIN rail standard length) DIN rail mounting (Without DIN rail) D DO Order DIN rail separately Refer to p.2.10-17 for DIN rail part number.
Auto Switches/Proper Mounting Position for Stroke End Detection A 22 D-A9 D-F9 D-F9 W B W 20 (22) A D-A9 V D-F9 V D-F9 WV W B Dimension inside ( ) is for model D-A9 V.