5.5 58 8.5 1.5 8.5 11 M3 x 0.5 7.5 M2.5 x 0.45 16 (12 x 2) 33 24.5 6 6.5 2 18 11 5.5 64 9 3 9 11 M4 x 0.7 10 M3 x 0.5 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z 12 (10 x 2) 3.4 6.5 2.5 M3 x 0.5 6 16 18.5 8 26 14 49.5 39 52 10.2 23 M4 x 0.7 6 4.2 16 (12 x 2) 3.4 6.5 2 M3 x 0.5 6.5 16 18.5 8 28 14 53 42 57 10.2 24 M4 x 0.7 6 4.3 6 JMGP Series Bore Size 20 (16 x 2) to 40 (32 x

No anchor bolt is included. *10 Weight when the circulating fluid is not included. *11 The capacity is 60 Hz even in the 50 Hz area when option C is selected. *12 The capacity is 60 Hz even in the 50 Hz area when option P is selected. *13 The weight will increase by 4 kg when option C and P is selected. 11 A Thermo-chiller Compact Dual/Basic Type for Lasers HRLE Series Scheduled to acquire

Fittings & Tubing Air Cylinders Rotary Actuators M5 x 0.8 (A port) 14 5 10 26.4 2 x 3.2 (For mounting) 17 3 2.5 Manual override A 11 G: Approx. 300 H: Approx. 600 (Lead wire length) 48.6 [50.8] (Light/surge voltage suppressor) 41.5 [48.5] + 35.6 28.5 26.1 R P X 13 5 5 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors 10 10 8.6

AS-FG AS301FS, AS311FS AS401FS, AS411FS AS-FP Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FM 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 AS-D 06, 07 1000 AS-T 500 ASP 500 ASN 0 0 5 0 10 5 0 10 AQ Number of needle rotations Number of needle rotations ASV Note) The numbers above the flow rate characteristic curves

AS-FG AS-FG AS301FSG, AS311FSG AS401FSG, AS411FSG AS-FP Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FM 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 AS-D 06, 07 1000 AS-T 500 ASP 500 ASN 0 0 5 0 10 5 0 10 AQ Number of needle rotations Number of needle rotations ASV Note) The numbers above the flow rate characteristic

9 (6.5) 18.5 11 15.5 27.5 22 15 5 22 15 17.5 37.5 18.5 11 9 (6.5) 18.5 11 16.5 35 ( ): D-A93 For actual setting, check the operation of the auto switch and adjust as necessary.

Magnet lever Note) Note) These items (no. 11, 13, and 14) consist of auto switch unit and angle adjuster. Refer to pages 140 and 141 for detailed specifications.

x 10-11 (FKM) 1.3 x 10-9 CYV Q1 R1 R2 R3 S1 T1 U1 Kalrez 4079 SS592 SS630 SSE38 1232-70 3310-75 1.3 x 10-10 (FKM) Note 1) Values at ambient temperatures, excluding gas permeation.

Main circuit of switch OUT Black Weight DC () Blue (g) D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model D-Y7PW, D-Y7PWV 0.5 11 11 11 Lead wire length (m) 3 54 54 54 DC (+) Brown 5 88 88 88 Main circuit of switch Main circuit of switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw Indicator light DC () Blue 3.4 2.5 D-Y7BW, D-Y7BWV SMC SMC 6.2 5 29 OUT (+) Brown Most

9.5 0.5 11 9.5 26.5 ( ): Denotes the values of D-A93.

Main circuit of switch OUT Black Weight DC () Blue (g) D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model D-Y7PW, D-Y7PWV 0.5 11 11 11 Lead wire length (m) 3 54 54 54 DC (+) Brown 5 88 88 88 Main circuit of switch Main circuit of switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw Indicator light DC () Blue 3.4 2.5 D-Y7BW, D-Y7BWV SMC SMC 6.2 5 29 OUT (+) Brown Most

Main circuit of switch OUT Black Weight DC () Blue (g) D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model D-Y7PW, D-Y7PWV 0.5 11 11 11 Lead wire length (m) 3 54 54 54 DC (+) Brown 5 88 88 88 Main circuit of switch Main circuit of switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw Indicator light DC () Blue 3.4 2.5 D-Y7BW, D-Y7BWV SMC SMC 6.2 5 29 OUT (+) Brown Most

Main circuit of switch OUT Black Weight DC () Blue (g) D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model D-Y7PW, D-Y7PWV 0.5 11 11 11 Lead wire length (m) 3 54 54 54 DC (+) Brown 5 88 88 88 Main circuit of switch Main circuit of switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw Indicator light DC () Blue 3.4 2.5 D-Y7BW, D-Y7BWV SMC SMC 6.2 5 29 OUT (+) Brown Most

Main circuit of switch OUT Black Weight DC () Blue (g) D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model D-Y7PW, D-Y7PWV 0.5 11 11 11 Lead wire length (m) 3 54 54 54 DC (+) Brown 5 88 88 88 Main circuit of switch Main circuit of switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw Indicator light DC () Blue 3.4 2.5 D-Y7BW, D-Y7BWV SMC SMC 6.2 5 29 OUT (+) Brown Most

When it is confirmed that there are no abnormalities with the unit after turning it ON, select the [OK] button. -132No.EX-OMX1011 (11) To change the Password, select [Admin Manager] and select [Change Password]. Input the old password first and the new password twice, and select [Store] to change the password.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure Alarm flag 1 6 Reservation 7 Reservation 8 CH1 abnormal rise of circulating fluid temperature 9

<9> Overload judging time setting Sets time for judgment of overload <10> Output ratio indication Indicates output ratio of controller <11> Temp. upper/lower limit alarm sequence setting Determines whether or not temp. upper/lower limit alarm is output when power is turned on.