Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: Base Mounted, Stations: 4 Stations, A Port Size: M3X0.5 Type 41, S41, P R Port Thread: -

Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: Base Mounted, Stations: 6 Stations, A Port Size: M3X0.5 Type 41, S41, P R Port Thread: -

Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: Base Mounted, Stations: 10 Stations, A Port Size: M3X0.5 Type 41, S41, P R Port Thread: -

Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: Base Mounted, Stations: 20 Stations, A Port Size: M3X0.5 Type 41, S41, P R Port Thread: -

Valve Mounting Direction: Solenoid on Same Side as A Port, Piping: Base Mounted, Stations: 3 Stations, A Port Size: M3X0.5 Type 41, S41, P R Port Thread: -

Valve Mounting Direction: Solenoid on Same Side as A Port, Piping: Base Mounted, Stations: 4 Stations, A Port Size: M3X0.5 Type 41, S41, P R Port Thread: -

1 14143 14144 14147 Stainless steel NBR 15-9-30 4 Speed Controller: Standard Type In-line Type Series AS Dimensions: AS1000-M3 Dimensions: AS1000-M5 Male M5 x 0.8 Female M5 x 0.8 Dimensions: AS2000/3000 Dimensions: AS4000 2-1/4 to 1/2 AS 2-port size ASP ASN AQ ASV Dimensions AK Max. Min.

M1 Weight (g) ASV120F-M3-04 ASV220F-M5-04 ASV220F-M5-06 Model 5 8 9 M3 x 0.5 M5 x 0.8 M5 x 0.8 5.5 8 8 9.3 9.3 11.6 7.2 9.6 9.6 21.4 22.8 23.6 25 27.6 28.4 9.8 11.1 11.1 28.6 31.4 31.4 26.1 28.6 28.6 25.8 27.7 27.7 23.3 24.9 24.9 12.7 12.7 13.5 4 4 6 Reference dimensions of M thread after installation. Inch Size Applicable tubing O.D. d T H D1 D2 L1 L2 L3 L4 A Max. Min. Max. Min.

side) Motor cable mounting direction: Nil (Top entry) Rod operating range Note 1) 2 x M5 x 0.8 thread depth 9 [1] 1 20 Motor cable length 300 2 x 5 Origin Note 2) Stroke end [Origin] Note 3) 20 [Stroke end] M5 x 0.8 thread depth 9 Manual override screw 21 42 28 12 Note 5) 28 Motor cable mounting direction: L (Entry on the left side) A 7 12 Stroke L2 L1 Mounting surface 18 5.5 12 Note 5)

Weight (g) d T H D1 D2 D3 L1 L2 L3 Model 4 ASD230F-M5-04 9.3 12.9 17.5 29.4 12 25.5 28.6 25.8 28.3 9.6 10 7.8 11.7 M5 X 0.8 8 25 22.2 6 ASD230F-M5-06 11.6 13.7 20.6 32.5 13 34.6 39.6 6 14 ASD330F-01-06S 11.6 13.7 22.9 29 38.5 36.1 31.1 14.2 11.8 10.6 R(PT)1/8 12 32.1 27.1 15.8 33.9 38.9 8 ASD330F-01-08S 15.2 18.5 28.2 31 44.8 6 ASD430F-02-06S 12.8 17 25.2 53 43.5 18 8 36.7 ASD430F-02-08S

Connection thread size (R, NPT, G) Proper tightening torque [Nm] 1/16, 1/8 3 to 5 1/4 8 to 12 3/8 15 to 20 1/2 20 to 25 Body size Maximum allowable torque [Nm] M5 0.05 1/8 0.07 1/4 0.16 3/8 0.2 1/2 0.4 2. Insufficient tightening may cause seal failure, or loosen the threads. 3.

x 0.8 KK 9 NH NW 53 NE NF MY1B25 MY1B32 MY1B40 110 9 5.5 16 24.5 54 M6 x 1 9.5 5.6 18 40.2 39 110 40.5 55 42 9 M5 x 0.8 30 MY3A MY3B 140 11 6.6 19 M8 x 1.25 2 28.5 68 M5 x 0.8 16 10 6.8 22 50.2 49 64 140 70 52 50 12 M6 x 1 37 170 14 8.5 23 M10 x 1.5 2 35 84 M6 x 1 15 13 170 8.6 85 26.5 62.7 62 61.5 75 64 12 M6 x 1 45 MY3M Centralized piping YW P PA PB Q PP RR QW T TT WW XXX YH Z ZZ Model

x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 ( ): Denotes the values of D-A44C Dimensions (mm) D-A3C D-A44C 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 G 1/2 4 x Z 4 x Z (Applicable cable O.D. 6.8 to 9.6) (Applicable cable O.D. 6.8 to 11.5) Hexagon socket head cap bolt Hexagon socket head cap bolt Indicator

Consult SMC concerning water resistance, elasticity of lead wires and usage at welding sites. 18 Series CRJ/ Specific Product Precautions Be sure to read before handling. Refer to pages 12 through 18 for safety precautions, rotary actuator precautions and auto switch precautions.

valve Measurement distance: 1m R(PT) R(PT) M3 M5 1 8 1 8 Port size Fluid Noise reduction dB(A) 16 21 13 18 Compressed air Max. operating press Ambient and fluid temperature 1.0MPa 5 to 50C Effective area (mm2) Weight (g) Dimensions (mm) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Note) NPT thread for AN101 and AN110 is alsoavailable.

Refer to page 18 for part numbers of One-touch fittings. Fitting direction is specified when the fittings below are used. Assemble the fitting so that the D-cut surfaces of the fitting face sideways. Fitting part no.: that it does not come out.

VQZ300 Port size Symbol VQZ200 VZ 1 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 M5 thread Rc (PT)1/4 C4 C6 C8 C10 M5 02 Metal seal Rubber seal 1 (P) 3 (R) VT (A) 2 N.O. 2 VT 1 (P) 3 (R) Note 1) Refer to p.2.10-18 for inch size Onetouch fittings. VP (A) 2 N.C. 3 VG 1 (P) 3 (R) Manual override (A) 2 N.O.

C J G5-S CV MVGQ CC Series Variations Series Basic type With cap or bumper (Option) Stopper nut (Option) Hexagon nut Page Foot bracket RB Series RB J 18-10-2 Series RB D-X Coolant resistant Series RBL 18-10-8 20(Except 08 type) Series RBQ Data 18-10-10 Series RBQ 2 Hexagon nuts are attached for Series RB and standard models RBQ. 10-18-1 2 Shock Absorber Series RB Specifications Model RB0805

Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.