Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor],

For vacuum equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www. smcworld.com Nozzle diameter Port size 05 0.5 mm 07 0.7 mm Nil 6 One-touch fitting 01 Rc1/8 female thread Symbol EXH Vacuum pressure reached S 90 kPa L 48 kPa Mounting P V Caution Specifications 1 .

When using seal tape, leave one thread exposed when wrapping fitting or pipe. 0.25 f-t-+-t---t-+--j--+--:--t--+-I Set point -~V '" Q. ::; O Mount vertically. c.> 0.2 :; :2 l' Q. Qi '5 0 ~ 5l :r 0. 31<.-t-~-+---="I--;;::'--t-t_1 Q. 0.15 f-t.,---+t--t-+---1--+-t--t-l 8Tightening torque of mounting screw (M3) for gauge is 3-Skgf . cm.

(Values at the initial period) VFN Base mounted JIS Symbol Solenoid Specifications Option Grommet (G), Plug connector (L), Plug connector (M), DIN terminal (D) 100, 200, 24 , 48 , 110 , 220 Electrical entry DC AC 50/60 Hz Coil rated voltage (V) 24, 6 , 12 , 48 Allowable voltage fluctuation (%) 15 to +10% of rated voltage Caution Coil insulation type Class E or equivalent (120C) (2) Temperature

Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6

), Pressure Sensor: T2 (-100 to 200 KPa), Option: Y (Vacuum "V" port Release to Atmosphere Type, Check Valve: 1 pc)

Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C6U (Metric; Vacuum Port: ø6; Supply Port: ø6), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar

Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor

Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor

Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor

Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor

Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor