Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
2 Port for Oil Dimensions (mm) (N.C.) 1in = 25.4mm Grommet: G Conduit: C Approx. 300 V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port
Applicable cylinder MY3A16, MY3B16 MY3A25, MY3B25 MY3A40, MY3B40 MY3A63, MY3B63 A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 Data 091 130 182 Guide for Using Side Support For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.
26 52 4.5 44.5 25 26.3 115 79.9 VCC 1/2 63 49.6 29 14.5 103.3 111.3 155.8 26 26 52 4.5 44.5 25 26.3 115 79.9 3/4 80 59 35 17.5 112 120.5 165 35 31 62 5.5 48 30 31 124.2 85.8 1 90 74 44 22 135.9 144.5 189 40 36 72 6.5 60 35 39.5 148.2 96.8 383 Series SGC How to Fix an Auto Switch Auto Switch Proper Mounting Position (mm) D-M9l Model A B A B A B A B A B A B A B A B A B 5 SGC(A)2lll-05l10, 15
Comply with the requirements for FISCO field device Class I, Division 2, Groups A, B, C, and D; T4/ T5/T6 Ex ic IIC T4/T5/T6 Gc Class I, Zone 2 AEx ic IIC T4/T5/T6 Gc Ui 32 V, Ii 380 mA, Pi 5.32 W, Ci 5 nF, Li 10 H.
Enclosure Based on IEC529 Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20C, at rated voltage, without surge voltage suppressor.)
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4.
New valve (Blue) Manual override + B A Interface Pilot valve (V111) Adapter plate Existing valve (Orange) Manual override + B A Interface Pilot valve (SY114) Adapter plate 647
2 For 40 to 100 12 BUSHING 1 32 TIE ROD 4 13 HEXAGON SOCKET CAP BOLT 4 33 TIE ROD NUT 8 14 HEXAGON SOCKET CAP BOLT 2 34 WEAR RING B 1 15 WEAR RING A 2 35 ROD END NUT 1 16 PISTON SEAL A 1 36 MAGNET (1) For MDWB 17 ROD SEAL A 1 37 ROD SEAL B 1 18 GASKET 1 38 PISTON SEAL B 1 19 ELEMENT 1 39 CUSHION SEAL 2 20 RELEASE BOLT 1 40 CUSHION VALVE SEAL 2 41 CYLINDER TUBE GASKET 2 43 - Revision history
Possible to use as a 2-port valve by plugging the 3(B) port.
A2 Bracket B (Horizontal mounting) Part no. Option Note ZS-28-CA-4 Sensor connector For PF3A7H ZS-46-A1 Bracket A Tapping screw: Nominal size 3 x 8 L (2 pcs.) ZS-46-A2 Bracket B Tapping screw: Nominal size 3 x 8 L (2 pcs.)
Diaphragm B moves to the right, and at the same time diaphragm A also moves to the right Air exhaust port (AIR EXH) Switching valve Air supply port (AIR SUP) Pilot valve B Pilot valve A Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Shaft Suction port (FLUID IN) Diaphragm A Diaphragm B Drive chamber A Drive chamber B Control unit pushing pilot valve A. 3.
Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ O-ring NBR u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 O-ring NBR ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.
-J A-16.5mm B-19.5mm PH~D-PH9 Note) If the switch number is written, then the switch actuating rod assem bly is included.
Cv C[dm2/(sbar)] b Cv Flow characteristics 1 2 (P A) 2 3 (A R) Body ported Max. operating frequency (c/s) (AC/DC) (1) 15 21/21 or less 0.125 15 21/21 or less 0.250 Response time (ms) (AC/DC) (2) Weight (kg) (3) Note 1) Minimum operating frequency: As per JIS B 8373 (Once in 30 days) Note 2) Based on JIS B 8375-1981 (Supply pressure; 0.5 MPa; without surge voltage suppressor) Note 3) Value
12.5 10 3.5 AS2001F-03-3 AS2001F-06-3 44.8 6.3 21.8 49.1 43.6 13.5 5/32" 9.3 40.7 5.2 20.7 48 42.5 12.7 11.6 6 AS2001F-05-3 AS2051F-06-3 12.5 53.2 6.7 25.7 53.5 48.1 17 3/16" 11.4 50 6.2 21.6 48.9 43.4 16.5 12.8 6 14 10 3.5 17 15.5 13 3.5 AS2001F-07-3 AS2051F-08-3 59.8 8.1 27 54.8 49.4 18 1/4" 13.2 52.2 7.1 22.5 49.8 44.3 17 8 15.2 AS2051F-05-3 AS3001F-06-3 59 7.4 31.3 60.1 54.7 17 3/16"
Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1
pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 200 3 400 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 6 Effective area (mm2) Effective area (mm2) Effective area (mm2) 06, 08 08, 10 1.0 300 06 04 2 4 50 100 200 0.5 1 2 100 0.0 0 0 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) Number of needle rotations (turns) ASG520F