4 x Sa Thread depth Sb 2 x L O H I N G A M Vacuum flow Dust bag When dust bag is mounted T F E D Suction air Discharge air Suction air U C C B Hose band V (mm) A 73 B 34 C 19 D 10 E 13.2 F 16.2 G 69.8 H 31 I J 35 K 27 L 4.5 M 35 N 18 O P 13 Q Rc1/8 R 28 Sa M3 x 0.5 Sb 5 T 300 U 150 V 190 Model ZH10--X185 ZH20--X185 4 1 M4 x 0.7 8 400 200 250 119.5 55 32 15 19.5 23.5 111 48 56 48 4.5 56.5

8 22 8 15 80 18 M6 x 1 20 40 36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2

Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 221 230 PE PA 137 144 128 118 85 78 OUT IN EXH 55 55 25 Rc 1/4 (EXH port) 36 36 82.6 (IN, OUT port) 2-Rc 3/4, 1, 1 1/4 When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face.

No.PF-OMM0004-D / / PF3W7## SMC 2 11 13 14 16 17 19 21 24 26 26 F1 OUT1 60 F2 OUT2 36 F3 42 F10 43 F20 47 F22 48 F30 50 F80 51 F81 52 F82 53 F90 54 F98 55 F99 56 57 61 61 65 65 71 79 81 88 -1No.PF-OMM0004-D (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.

-40A VNA7-50A 1 8 1 4 1 4 1 4 1 105 120 140 77 96 113 53 60 74 26.5 30 37 120.5 137 160 20 24 24 129.5 147 170 170.1 187.6 210.6 211.5 229 252 55 63 74 1 2 1 2 564 A VNA Series Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control How to Order Pilot Solenoid Valves Valve size 1/2/3/4 Valve size 5/6/7 SF4 5 D 23 Q VO307 5 D 1 Q CE-compliant CE-compliant Coil rated voltage

center) Rc 3/8: 49 Rc 1/2: 55 VH402-02 to 06 VH412-02 to 06 2 (Position) 1/4 to 3/4 2 1 1.28 VH4 Handle Operation Angle and Air Flow Direction VH420-02 to 06 VH430-02 to 06 3 (Closed center) (Refer to the figures of piping direction to the right.)

M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53 70.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 44.3 5.4 15.4 55 2.3 30.3 36.5 17.5 6 AR30-A 1/4, 3/8 1/8 53 83.5 27 28.5 M45 x 1.5 28.5 37.5 65 37.5 66 41 36 46 6.5 24 65 2.3 32.5 45.5 22.5 7 AR40-A 1/4, 3/8, 1/2 1/8 70 100 33.5 34.5 M52 x 1.5 34.5 42.5 72 42.5 72 50 38 54 8.5 26.5 70

4 1 105 120 140 77 96 113 53 60 74 26.5 30 37 120.5 137 160 20 24 24 129.5 147 170 163 180.5 203.5 175.5 193 216 219.5 237 260 222.5 240 263 229.5 247 270 55 63 74 1 2 1 2 17-4-9 6 Series VNA Precautions Be sure to read before handling.

5 XL-OMV0002 2.2 Assy Assy 16 25 40 50 XLC16-30-1 XLC25-30-1 XLC40-30-1 XLC50-30-1-1 XLC16-30-1H XLC25-30-1H XLC40-30-1H XLC50-30-1H-1 63 80 100 160 XLC63-30-1-1 XLC80-30-1-1 XLC100-30-1-1 XLC160-30-1-1 XLC63-30-1H-1 XLC80-30-1H-1 XLC100-30-1H-1 XLC160-30-1H-1 1) M9// 2 (FKM:No.1349-80) XLC16-30-1-M9//-XN1 3)Assy / 16 25 40 50 AS568-025V AS568-030V AS568-035V AS568-039V AS568

Dimensions inch (mm) AK3652 & 4652 1.50 (38) 2.17 (55) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: 4T, 6T Connections: N, BRN Connections: 4, 6, BR 4 6 4 6 4 6 25.4 45 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70 (43.2) NPT 1/4

Pin description 4 2 1 DC(+) 2 OUT2 1 3 DC (-) Connector on the body 4 OUT1 Connector pin numbers (male connector) 3 4 2 No.

LJ1-7-G/Matsushita Electric Industrial Co., Ltd. 100 Driver Non-standard motor electric actuators LJ1 and LG1 75 90 5 30 (195) AC servomotor short stroke electric actuator LX How to order 13 G LJ1 05 Compatible model 1 B 1 LJ1-7-R/Mitsubishi Electric Corporation Brake G R Y Nil B Matsushita Electric Industrial Co., Ltd.

0~55 -8- NOx 0.1ppm a.0~55 b.35~65%RH c. d. e. f. g. h. i.() j. k. l. m. n. (IDF )(AF/AFF )(AFM/AM , -9- 4 4 4 4-2. 2. 2. 2. 4-2-1. D D 4-2-2.

0 VEX IC-0(Internal sensor type) IC-1(External sensor type) No. q w e r Description Note Breathing port (M3 x 0.5 x 9.5) Breathing port (M3 x 0.5 x 9.5) Power supply, 10 bit input cable 13 wire, O.D. 6.8 mm, 1 mm length AMR Pneumatic regulator connection cable 5 wire, O.D. 6 mm, 1 mm length q q Cable for 4 point switch output ITV 3 wire, O.D. 3.4 mm, 1 mm length Cable for external sensor

Applicable bore A B A B A B MY-S25 MY-S32 MY-S40 ML1C25 ML1C32 ML1C40 103 117 35 50 8 5 9.5 5.5 M6 x 1 128 146 45 64 11.7 6 11 6.6 M8 x 1.25 148 170 55 80 14.8 5 14 9 M10 x 1.5 1114 A Hy-rodless Cylinder ML1C Series Construction #9 %7 #8 #7 %6 !0 CLJ2 CLM2 CLG1 CL1 w $8 @4 i u !7 t !2 $9 !3 !1 %5 @6 @5 $5 #6 MLGC %2 CNG @8 !9 MNB e CNA2 $2 q %3 %4 $1 CNS #1 #0 @9 #4 $0 !5 !

0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 A M5 M5 M5 2 1 4 R 2 1 0.11 0.16 Weight (kg) (1) 0.19 0.25 0.35 0.55 0.75 1.5 2 4 Hysteresis (2) 1% F.S. 2.5% F .S. 3% F .S. 5% F .S.

8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 2 M5 M5 AMR 1 4 2 1 (5) (5) Weight (kg) 0.15 0.18 0.2 0.3 0.5 1.4 2 4 ITV Note 1) No condensation.

Valve model Port size VCL2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCL4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCL Direct Operated