Style Standard stroke (inch) Standard stroke (inch) Page Page Standard type Standard type Single rod 1 012 (1/8"), 062 (5/8"), 125 (1-1/4"), 250 (2-1/2"), 050 (1/2"), 100 (1"), 200 (2"), 400 (4") 037 (3/8"), 087 (7/8"), 175 (1-3/4"), 350 (3-1/2"), 025 (1/4"), 075 (3/4"), 150 (1-1/2"), 300 (3"), 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") Double acting Double rod 13

-www.stevenengineering.com Maintenance space female thread Drain M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 1 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AFF75B 1 2 13 42 348 220 57.5 220 10 AFF75A to AFF220A/Dimensions 3-20 holes For anchor bolt mounting Label Drain Rc ORIENTATION G 184 184 236 12B AFF220A 4BJIS10k flange

7.7 (Pitch) P=10.5 10.5 (2 port) M5 x 0.8 L plug connector (L) M plug connector (M) 32.5[34.7] <34.7> 11.6 38.1[45.1] <42> 42.3[44.5] <44.5> 27.5 Other dimensions are same as grommet style.

8 18 18 4.5 4.5 7 13 8 18 18 22 4.5 4.5 3.5 2.5 14 13 8 9 18 18 29 29 3.5 3.5 4.5 4.5 Auto Switch Mounting When using the solid state auto switch (D-M9), mount it in the illustrated direction.

60 106 (170) 6H9 (+0.030 0 ) depth 7 58 74 6H9 (+0.030 0 ) depth 7 7 A (Table traveling distance) L (86) 13 61 90 13 85 68 53.8 (68) 33.5 31 Vacuum port Rc1/8 n x 6.6 76 B D x 150 (= E) 150 60 Dimensions [mm] Dimensions [mm] Model L A B n D E 11-LEFG40-S-150 354 157 328 4 150 11-LEFG40-S-200 404 207 378 6 2 300 11-LEFG40-S-250 454 257 428 11-LEFG40-S-300 504 307 478 11-LEFG40-S-350 554

(mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

Series AMD Dimensions: AMD850 Accessory D: With auto drain (N.O.) for AMD850 Options T: With element service indicator HAl AT IDl AMG AFF AMl Related poroducts M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6 11/2 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMD850 13 42 348 220 57.5 220 10 AMD850SAM, #7 4.6-12 Series AMD Precautions

Nil Without auto switch Symbol Position detector arms Switch bracket Positioning angle c a b c d 10 11 12 13 14 15 20 23 25 180 Refer to the table below for auto switch part numbers. X X X X X X X X X X X X 90 X b d X X X Table position detector arm X X X X X X a Switch mounting bracket X Cylinder unit/Applicable auto switch types Load voltage Lead wire length (m) Auto switch part no.

Colors indication Longer lengths available upon request Color Black White Red Blue Yellow Green Symbol B W R BU Y G T0645 6 4.5 36 T1613 16 13 100 T0604 6 4 24 T1209 12 9 75 T0425 4 2.5 13 T0806 8 6 48 T0403 4 3 25 T1075 10 7.5 60 Model O.D. mm I.D. mm Min. bending radius mm Length 20m 100m Roll Reel Specifications Operating fluid Max. operating pressure Burst pressure Air, Water 218psi

Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I

Refer to pages 1315-3 to 13-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to page 13-1-5 for Precautions on every series. Air suction filter Air suction filter Mounting Vacuum line Vacuum line Construction Warning 1. Be extremely careful with the piping connection screw seal to prevent leakage.

4.7 C6 4.7 N3 4.7 N7 7.3 A B C D E F ZHP63BM 26 45.8 63 68 12.5 33.8 ZHP80BM 28 57 80 85 18 41.8 ZHP63UM 26 63 66 5 20.3 ZHP80UM 26 80 83 5 20.3 Circuit Adapter Dimensions (by Mounting Style) [mm] G H J K L M ZHPmmmA-mmS 25.7 22.6 5 13 M8 ZHPmmmB-mmS 27.1 21.2 6 17 M10 ZHPmmmC-mmS 13 36.7 M8 depth 10 ZHPmmmD-mmS 17 39.1 M10 depth 10 ZHPmmmE-mmS 27.45 21.8 6.75 12.7 5/16-18UNC ZHPmmmF-mmS

Caution 13 No.JSY1000V-OMW0004-A JSY1000/3000/5000 series Specific Product Precautions 5 Be sure to read this before handling.

Specification SV1000 SV2000 Applicable series Stacking type cassette base manifold Manifold type Common SUP, EXH 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) 18 stations 20 stations Max. number of solenoids 18 points 26 points 1(P)/3, 5 (E) port C8, N9 C10, N11 Port size C3, C4, C6 N1, N3, N7 C4, C6, C8 N3, N7, N9 4(A)/2(B) port Flow Characteristics Flow characteristics Port size

: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads 5 wire oil resistant heavy duty cord (0.15mm) 01/T1 types approx. 60g, W1 type approx. 80g, C4/C6/M5 types approx. 92g (each including 0.6m lead wires) Port size Lead wires Weight Note: When equipped with auto shift function, the following ranges can be set.

: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads Lead wires Weight 5 wire oil resistant heavy duty cord (0.15mmX) 01/T1 types approx. 60g, W1 type approx. 80g, C4/C6/M5 types approx. 92g (each including 0.6m lead wires) Note: When equipped with auto shift function, the following ranges can be set.

: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads 5-wire oil resistant heavy-duty cord (0.15 mm2) 01/T1 types approx. 60 g, W1 type approx. 80 g, C4/C6/M5 types approx. 92 g (Each including 0.6 m lead wires) Port size Lead wire Weight Note) When equipped with auto shift function, the following ranges can be set.

L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.

Symbol Position detector arms Switch bracket Positioning angle For the applicable auto switch model, refer to the table below. a b c d 10 11 12 13 14 15 20 23 25 180 X X X X X Data X X X X X X X 90 b d X Table position detector arm X X X X X X X a X Switch mounting bracket X X Cylinder Unit/Applicable Auto Switch Load voltage Lead wire length (m) Auto switch model Electrical entry Wiring