Fittings & Tubing Air Cylinders Rotary Actuators 63.5+ST ST 50+ST 8 5.5 16 2 x 3.2 through 15+1/2ST 2.75 19 2 x 6.5 counterbore depth 3.3 14 1 OUT 3 3 1 3.2 5.6 (16) 280.2 280.2 22.7 35 16 37 6.3 5 6 M3 x 0.5 x 12.5 L and M3 x 0.5 (Hexagon bolt) (Hexagon nut) 7 2 x M5 x 0.8 thread depth 4.5 IN (Piping port) 2 x M3 x 0.5 (Through-hole) 2 x M3 x 0.5 (Through-hole) 4 x M5 x 0.8 thread depth
T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 Model M 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Controller Connectors These are connectors 'all halfpitch type' used for CN1 (control input/output) and CN2 (general purpose input/output).
T-nuts (weight 10.0g) Dedicated communication cable (IBM PC/AT compatible computer) M Model LC1-1-RC M Model 17.5 LC1-1-N3 M3 x 0.5 Cable length 02 2m 04 4m 03 3m 05 5m LC1-1-N5 M5 x 0.8 18 7.5 PC Controller T-brackets Model LC1-1-L5 (weight 16.0g) Model LC1-1-L3 (weight 15.5g) Cable length: 2 to 5m M5 M3 17.5 17.5 11 Dedicated communication cable (D-Sub) (for NEC PC-98 Series) Model LC1-
Refer to pages 18 through 21 for safety instructions and precautions for 2/3 port solenoid valve for fluid control. Replacement Parts Fluid Flow Direction Caution Solenoid coil part numbers The maximum operating pressure differential differs depending on the flow direction of the fluid.
Cool from 30C (303 K) to 20C (293 K). : Tap water Density g: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath * Refer to the information shown below for the typical physical property values by circulating fluid.
Mounting method Mounting screw (M3 x 8) (Included parts) O-rings Tightening torque ZNC20 : 0.63 [Nm] ZNC20P: 0.32 [Nm] ZNC20S: 0.63 [Nm] Model Single unit part no. Size ZNC30m ZNCM-30DR 10.5 x 8.5 x 1 ZNC(40, 60)m ZNCM-40DR 13.5 x 11.5 x 1 ZNC80m ZNCM-80DR 20 x 18 x 1 Air supply port PC Sales unit: 10 pcs.
Width across flats 3.5 M3 x 0.5 4 9h9 6.4 12.5 6.5 5.5 2.4 5.5 2.4 2.5 Rod end nut part no.: NTJ-006A 4 Series CUJ Dimensions (mm) 8 Double Acting/Single Acting 1in=25.4mm Without magnet/CUJB8 Note) The angular position of the width across flats is not fixed with respect to the tube. 2-M3 x 0.5 (port size) M3 x 0.5 effective depth 6 Element 3 6 3.5 Width across flats 10 Width across flats
x 0.5 x 12.5l and M3 x 0.5 (hexagon bolt) (hexagon nut) 6 2-M3 x 0.5 (through) 2-M5 x 0.8 thread depth 4.5 (piping port) IN 7 2-M3 x 0.5 (through) 13 + ST 2-M5 x 0.8 thread depth 4.5 (piping port) (same on reverse side) 10 2-M3 x 0.5 thread depth 4.5 (same on reverse side) 4 8 6 11 22.5 (13) (10 + 1/2ST) 4 Model ST 13 + ST 45 + ST 58.5 + ST 10 + 1/2ST CXS6-10-XB19 10 23 55 68.5 15 CXS6-20
Air Flow Max. flow line Pressure drop (MPa) Max. air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) Model Selection Select the model in accordance with the following procedure taking the inlet pressure and max. air flow into consideration. (Example) Inlet pressure: 0.6 MPa Max. air flow capacity: 5 m3/min (ANR) 1.
-t-~-+---="I--;;::'--t-t_1 Q. 0.15 f-t.,---+t--t-+---1--+-t--t-l 8Tightening torque of mounting screw (M3) for gauge is 3-Skgf . cm.
4 1.17-18 ALD600/900 Dimensions Related equipment/Strainer D.P. Lube ALD600-l06 to 10, ALD900-l12 to 20 At the terminal of an air pressure line in which a D.P. Lube is used, install a strainer (filtration rate of 5m) upstream with a metal seal solenoid valve, which is susceptible to dust.
28 12.5 8.5 31 67.5 36 6 18 86 66 53 99 53 44 62 22 1/4 M5 19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119
No.ZB-OM00301 / ZB No.ZB-OM00301 2 9 12 13 15 16 16 V Assy 17 21 25 26 28 28 29 30 30 31 31 32 35 37 38 39 40 Assy 40 Assy 41 42 1 - No.ZB-OM00301 1) (ISO/IEC) (JIS) 2 *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.
36 67.5 1/4 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 22 40 81.5 1/4, 3/8 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 VCB31 30 50 86 1/2 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101 71 68 104 22 45 90 1/4, 3/8 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 VCB41 30 50 94 1/2 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 35 60 102 3/4 41 17.5 17 36 30
Frequency (Hz) 50 60(53) 18 60 51(44) 12 Model Power source VX3 7.5 6 8 11 9.5 11.5 AC VXZ22 VXA DC 50 80 21 60 67 17 AC VXZ23 VN DC LVC JIS Symbol LVA OUT LVH IN LVD N.O.
Required ventilation rate [m3/min] Heat radiation amount [kW] Differential temp. of 6C between inside and outside of installation area HRSH090-A-20/40 Approx. 18 305 155 Differential temp. of 3C between inside and outside of installation area Model 152 A HRSH090 Series Specific Product Precautions 3 Be sure to read this before handling the products.
(Ball bushing bearing) (mm) AA A E DB Bore size (mm) Bore size (mm) AA E BD 75st, 100st Larger than 100st 37 57 63.5 64 75st, 100st Larger than 100st 50st 25st 50st 25st 50st 75st, 100st 25.50st Larger than 50st 25.50st Larger than 50st 25st Larger than 100st 114 134 160 180 25.50st Larger than 50st 147 168 188 93 63 80 100 63 80 100 41 45.5 46 118 142 162 106.5 115 137 172 198 233 20 25
DRV mon 1 Posn 123.45mm Speed MENUESC 41 - 6. 6.1 (1) LECP LECA No. TB Ver1.** TB Ver2.**2 TB Ver.5.11 LECPA PLC LECPLECA , , 1 1 LECPA aLECPLECA 100mm 42 - bLECPLECA 43 - (2) (2-1) LECPLECA INP ON ON INP OFF No.Step No.
(CN2SW) . 16 4.3 (LEC) . 17 5. . 19 5.1 CN4 . 19 5.2 CN3 . 19 5.3 CN1CONT . 19 5.4 CN2PC/TB . 20 .CN4 . 21 6.1 . 21 1 - 6.2 . 21 6.3 . 22 . 23 7.CN3 . 24 8.CN1IF (CONT) . 25 8.1 . 25 8.2 . 27 9.CN2TB/PC . 28 9.1 . 28 10.LED . 29 10.1 LED . 29 10.2 IF LED . 29 11. . 30 11.1 . 30 11.2 . 30 11.3 . 30 11.4 . 32 12. . 33 12.1 . 33 12.1.1 . 39 12.2 IF ( ) . 40 12.3 (IO ) . 41
VP3185DZA1-X81 MAX.10 160.3 6 140 87.4 26.5 EXH.1 56 76 81 EXH.2 105 (Non-locking) Manual override Applicable cable O.D. 6 to 8 Pg9 Rc 1/4 Pilot EXH 2-Rc 1/8 (External pilot port) 2-13 Mounting hole EXH 243.1 250.7 PA PE 159 166 150 140 105 90 IN EXH OUT 62 52 25 (EXH port) Rc 2 118 41 41 2-Rc 1 1/4, 1 1/2, 2 (IN, OUT port) When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned