100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.
Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500
70 94 58 65 200 200 480 610 220 220 225 238 Model HAA15 HAA22 B C D E F G H J K L M N P Q R S 1B union union 1 2 B 1 HA AT ID AMG AFF AM Misc. 14-15-3
AK ASS ASR ASF 15-9-11 3 Series AS Construction Component Parts No. q w e r t y u i o !0 !
4 y r t !3 e i o w !0 !5 Lateral load resisting type: MQQL (Built-in ball bushing) !1 !6 !
Standard strokes Bore size (mm) Standard stroke (mm) Long stroke (mm) 75, 100, 125, 150, 175 350, 400, 450, 500, 600 40, 50, 63 200, 250, 300 700, 800, 900, 1000 Intermediate strokes and strokes of 75mm or less can also be manufactured.
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 12-REA63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special orders.
Description Long 500 420 3 0.52 to 1.63 80 160 IF32 IF31 IF30 Long 1,000 800 4 0.61 to 1.91 160 320 Cover q SPCD SPCD 12 ADC Mounting plate SPCC Stainless steel 304 Stainless steel 304 w Long 1,800 1,450 5 0.69 to 2.23 280 560 Bellows e r PBP or Stainless steel 304 Long 2,600 2,000 6 0.70 to 2.28 400 800 Body C3604B or Stainless steel 304 ON-flow: Flow volume under which a microswitch starts
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read
For R, NPT Thread (With sealant) Tightening method 1. The proper tightening torques of the fittings are as shown in the table below. As a guide, tighten it by hand, then turn it two or three turns with a wrench. Check the dimensions of each product for the hexagon width across flats.
Flow direction (Right Left) Nil Rc1/4 F G1/4 *1 Nil Flow direction (Left Right ) R Flow direction (Right Left) *1: Conforming to ISO16030 *1: Conforming to ISO16030 Square embedded type pressure gauge Round type pressure gauge Refer to the WEB catalog for details.
Therefore, supply pressure regulated by a built-in regulator e passes through the air supply solenoid valve q and is applied to the pilot chamber r. The pressure in the pilot chamber r increases and operates on the upper surface of the diaphragm t. As a result, the air supply valve y linked to the diaphragm t opens, and a portion of the supply pressure becomes output pressure.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C HRL Series 3.3 Installation 3-27 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
For details, refer to the IDK series in the Best Pneumatics No.6. 705 MHY2 Series Construction Closed condition 10 16 20, 25 r o !8 e w !7 t !5 r o !8 e !6 w @0 !7 t !5 r o !8 e !6 w @0 !7 t !5 !0 u !2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !0 u !3 !2 i q !1 !4 y !9 Open condition Component Parts Note No.
Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G 2 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With bracket
Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G Features 1 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With