(Including insulating material) 2.35 mm 2.35 mm Rated current 10 A 8 A Rated voltage 600 V 600 V Contact resistance 5 mW or less Insulation resistance 100 MW or more Withstand voltage 1.4 kV Rating/Performance Ambient temperature Connector 25 to 80C Cable 30 to +105C 10 to +105C Min. bending radius (Fixed) 94 mm 110 mm Protection class IP67 (Only with screw tightened) Allowable repeated insertion

10% Power consumption 0.45 W Surge voltage suppressor Varistor Indicator LED Manufacturer OMRON Rockwell Automation Electrical wiring G1/2, M12 connector M12 connector Contact resistance 25 m or less 50 m or less Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance) Max. voltage 24 VDC Max. load current 50 mA Max. load inductance 0.5 H Insulation voltage 300 V 600

Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.

VBA2A: Qb = 600 [L/min (ANR)] VBA4A: Qb = 1050 [L/min (ANR)] Refer to Flow Rate Characteristics on pages 1012 and 1013. Avoid pulsation. (Max. 0.05 MPa) NO: Need no tank The VBA4A can supply necessary pressure. NO Judgement of flow rate YES YES The VBA2A cannot obtain necessary pressure. Select the tank from table below.

Bore size (mm) Standard stroke (mm) Bore size (mm) Rod diameter (mm2) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 32 675 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 1082 40 40 1651 50 2804 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 50 Theoretical force (N) = Pressure (MPa) X Piston area (mm2) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 Intermediate

VBA2lA: Qb = 600 [L/min (ANR)] VBA4lA: Qb = 1050 [L/min (ANR)] Refer to Flow-rate Characteristics on pages 3 and 4. Avoid pulsation. (Max. 0.05 MPa) NO: Need no tank The VBA4lA can supply necessary pressure. NO Judgement of flow rate YES YES The VBA2lA cannot obtain necessary pressure. Select the tank from table below.

Min. load impedance: 50 Analog current output Max. load impedance: Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance: 50 The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used.

, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.

1000 Manufacturable stroke range [mm] 11-LEFS16 V V V V V V V V V V 50 to 500 11-LEFS25 V V V V V V V V V V V V 50 to 600 11-LEFS32 V V V V V V V V V V V V V V V V 50 to 800 11-LEFS40 V V V V V V V V V V V V V V V V V V 150 to 1000 *Please consult with SMC for non-standard strokes as they are produced as special orders.

Applicable Stroke Table : Standard Model Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Manufacturable stroke range [mm] LEFS16 50 to 500 LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * Please consult with SMC for non-standard strokes as they are produced as special orders. The actuator and controller/driver are sold as a package.

W Note 2) 230 W Note 1) Cooling capacity 900 W Note 2) 600 W Note 1) Heating capacity Temperature stability Note 3) 0.018 to 0.054F (0.01 to 0.03C) Pump capacity Refer to performance chart.

bearing) 40 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer

mm) 1 4 1 4 02 3 03 D DIN terminal 3 8 3 8 DO DIN terminal (Without connector) 04 1 2 1 2 1 2 3 4 1 2 3 4 1 04 5 06 Body ported G Grommet (Lead wire length 300 mm) 10 1 1 1 H Grommet (Lead wire length 600 mm) 10 7 12 14 9 20 2 E Grommet terminal 1 4 1 T Conduit terminal 1 4 1 2 D DIN terminal 1 2 G Grommet (Lead wire length 300 mm) Grommet (Lead wire length 600 mm) DIN terminal DIN terminal

Relationship between Number of Needle Rotations and Piston Speed 32, 40 50, 63 800 800 32 32 50 700 700 600 600 63 Piston speed (mm/s) Piston speed (mm/s) 40 40 500 500 50 400 400 63 300 300 200 200 100 100 1 0 1 2 3 4 5 6 0 0 1 2 3 4 5 6 7 8 9 10 7 Fully opened Without restrictor Without restrictor Fully opened Number of restrictors needle rotations Number of restrictors needle rotations

Load impedance: 50 to 600 : IO-Link compatible product Used as IO-Link device -26No.PF-OMW0007-E Outline of Settings Power is supplied.

mm 2) Number of needle rotations Number of needle rotations Number of needle rotations 15-9-32 Speed Controller: Standard Type Large Flow In-line Type Series AS Construction: AS420/500/600 Construction: AS800/900 Component Parts No.

(24 VDC) Minimum load impedance: 50 PSE34 PNP open collector output (2 outputs), Max. 80 mA, residual voltage 1 V or less Analog output: 4 to 20 mA Maximum load impedance: 300 (12 VDC), 600 (24 VDC) Minimum load impedance: 50 ZSE ISE ZSP PS DC (+) DC (+) (Brown) (Brown) Analog output Load ISA Analog output (Gray) (Gray) + + Main circuit Main circuit Load PSE OUT1 OUT1 12 to 24 VDC 12

Note 3) 2-6-23 Base Mounted Series VQ5000 Kit (Lead wire cable) L 83 29.5 29.5 2-Rc 1/8 (Pilot EXH port) 12 21 47.5 36 PE R2 5 R1 3 1 P 2-G1 (Electrical entry) SMC 6-Rc 3/4 1(P), 5(R1), 3(R2) port Cable length L 0: 600 mm L 1: 1500 mm L 2: 3000 mm U D U D U D 179 106 46.8 59.2 83.5 U side Station number 55.5 M5 ground screw 9 9 Electrical entry on U side (LU) 19 34.5 n 12 X 2n-Rc 3/8, 1/2