1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 700 180 Angular Type Air Gripper MHY2/MHW2 Series MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 200 0.5 0.5 0.5 60 15 0.4 0.3 0.4 150 0.4 40 0.3 10 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40 Gripping
100 300 400 500 600 700 0.4 MXJ8 0.3 0.5 0.35 Rubber stopper 0.4 0.30 0.2 Load mass W kg Metal stopper 0.25 0.3 0.20 0.15 0.2 100 50 200 300 0.1 100 50 200 300 400 500 Average speed Va mm/s 0.10 500 700 Average speed Va mm/s Collision speed V mm/s 0.05 400 600 0.00 200 100 300 400 500 600 0 Collision speed V mm/s (Average speed x 1.4) 700 Table (2) Max.
VAC For three phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N W M N() W W P1 P1 PE PE P2 P2 CNP2 CNP2 P P(+) Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and L2
26 26.5 24 41 32 78 74 70 67.5 49 37 16 LQ3T6A-R6 1" 1/2" 30 26 24.5 22.5 24 64.5 62.5 29 9.5 LQ3T6A-R7 3/4" 3/4" 26.5 24 26.5 24 32 32 70 67.5 70 67.5 37 37 16 LQ3T6A-R9 3/4" 1" 3/4" 26.5 24 32 3/4" 1" 30 26 78 74 49 41 30 26 78 74 49 41 1" 8 18 36 32 70 67.5 37 49 LQ3T6A-R10 1/2" 1" 1/2" 24.5 22.5 24.5 22.5 24 24 64.5 62.5 64.5 62.5 29 29 9.5 LQ3T6A-R12 1" 1" 3/8" 30 26 22.5 19.5 41 21
1 0.5 30 0.5 0.8 Provide requisite conditions for selection.
L N VQ110VQ110YVQ110 ZQ1-VQ120Model Push-locking type Non-locking push type / Locking type (Tool type) Manual override Non-locking push type / Locking type (Tool type) Rated coil voltage 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC 12, 24 VDC DC 100 VAC 110 VAC 200 VAC 220 VAC 1 W 1 W 0.5 W 0.6 VA (6 mA) 0.65 VA (5.9 mA) 1.2 VA (6 mA) 1.3 VA (5.9 mA) Grommet
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.
200 300 300 5m/s 2m/s 2m/s 400 400 2) Flow rate : 60L/min 5) Flow rate : 60L/min 75 50 25 0 25 50 75 75 50 25 0 25 50 75 -75 -50 -25 0 25 50 75 -75 -50 -25 0 25 50 75 0 0 mm mm ionizer to workpiece [mm] ionizer to workpiece [mm] Installation distance from Installation distance from 200 200 10m/s 400 400 10m/s 5m/s 600 600 5m/s 800 800 2m/s 2m/s 1000 1000 3) Flow rate : 250L/min 6) Flow rate
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
temperature XLA16A-30-1H XLA25A-30-1H XLA40A-30-1H XLA50A-30-1H XLA63A-30-1H XLA80A-30-1H XMC XYC General use XLC16-30-1 XLC25-30-1 XLC40-30-1 XLC50-30-1 XLC63-30-1 XLC80-30-1 High temperature XLC16-30-1H XLC25-30-1H XLC40-30-1H XLC50-30-1H XLC63-30-1H XLC80-30-1H XMD XYD XLD25-30-1 XLD40-30-1 XLD50-30-1 XLD63-30-1 XLD80-30-1 General use : Standard High temperature XLD25-30-1H XLD40-30-1H
0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 200 400 600 800 1000 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa 6 Series IR1000/2000/3000 Series IR3000 Flow rate characteristics Relief characteristics Pressure characteristics Testing methods conform to JIS B8372.
Switch (When equipped with switch) L n 4 5 6 7 8 9 3 2 Internal Pilot Manifold L Dimension n: Stations (n1 + n2) L n 4 5 6 7 8 9 3 2 External Pilot Manifold L Dimension n: Stations (n1 + n2) L1 L2 L3 L4 L1 L2 L3 L4 148 137.5 124 12 160.5 150 134.5 13 173 162.5 145 14 185.5 175 155.5 15 198 187.5 166 16 210.5 200 176.5 17 210.5 200 187 12 223 212.5 197.5 13 160.5 150 134.5 13 173 162.5 145
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
Refer to the attachment table on page 1 or 5 for standard bypass port sizes applicable to AC. 30 01 00 AKM Check valve Bypass port size for redirecting air flow Body size 20 30 40 Body size Port size Symbol 20 30 40 01 02 03 1/8 1/4 3/8 Thread type Nil N F Rc NPT G 15 Attachment Specifications Series AC Pressure Switch (S) A compact integrated pressure switch can be easily installed and
ISA3-H Piping length: 1m, 3m, 5m : When the display value becomes 29 or lower, "0" is displayed. "0" and "30" are displayed near "30".