SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-Y-P-N02L-W"

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Boklet, X Options: Wetted Parts: Stainless Steel 316L

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Boklet, X Options: Wetted Parts: Stainless Steel 316L

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: None, Option 3: Operating Manual Boklet, X Options: Wetted Parts: Stainless Steel 316L

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: W/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Boklet, X Options: Restrictor Installed Fitting

Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: W/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: Wetted Parts: Stainless Steel 316L

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m

Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: W/Unit Display Switching Function, Option 2: None, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: Lead Wire Length 3m

Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: W/Unit Display Switching Function, Option 2: None, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: Lead Wire Length 3m

ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)