Please refer P 8-4 for how to mount. 9. Refer to Fig. 8-6 to mount the plug to the piping of the product.

Request message (Master to Slave) STX Slave Address Request Command ETX BCC [STX] XX XX [R] [P] [V] [1] [ETX] XX Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC [STX] XX XX [ACK] [P] [V] [1] XX XX XX XX XX [ETX] XX Communication example Slave AddressNo 1 BCC selection Your system This product (Request) [STX] 01RPV1 [ETX] [65h] Data

NPN) Reed switch Solid state switch Z76 5 V IC Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Relay, PLC 100 V, 200 V 2-wire 24 V Diagnostic indication (2-color) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC Grommet 100 V, 200 V 12 V 2-wire 3-wire (NPN) 3-wire (PNP) IC Relay, PLC 5 V, 12 V Diagnostic indication (2-color) 12 V 2-wire 24 V Water

CYRZ-V CYRZ-W CYRZ-X CYRZ-Y 12REA Warning 1. Do not disassemble the product because it may damage the air cushion mechanism.

Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V or less IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are

NPN) C76 5 V IC Reed switch Solid state switch Grommet B54 C73 C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF 100 V, 200 V 100 V 12 V Relay, PLC 2-wire 24 V Connector Diagnostic indication (2-color) Grommet G59 G5P K59 G59W G5PW K59W G5BA G59F 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC Grommet 2-wire 12 V Connector 3-wire (NPN) 3-wire (PNP) IC Relay, PLC 5 V, 12 V Diagnostic

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A4 (Bracket D for M12 Connector Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)