CU Minimum Stroke for Auto Switch Mounting (mm) D-A7lH, A80H D-F7lW, J79W D-A79W D-F7l, J79 D-F7BA, F7NT D-F7lF CQS D-A7l D-A80 D-A73C D-A80C Number of auto switches D-F7lV D-J79C D-F7lWV CQ2 MU 2 pcs. 5 10 15 15 1 pc. 5 5 10 15 Construction Component Parts No.
2 x M5 x 0.8 Piping port M5 x 0.8 Vacuum port 28 27 10 4.5 J depth 1.5 3 6 +0.030 0 10 9.5 4 Section AA B D Mounting base side +0.030 0 Q QL depth 1.5 3 11-/22-MXP10-20 Without magnet and switch rail Max. 2.5 2 x M2 x 0.4 depth 3 8 2.5 4.7 15 15 L 6 x M3 x 0.5 depth 4 2 x M3 x 0.5 depth 3.5 (mm) G H J K L M N Q QL S V W Z Model 11-/22-MXP10-10 8 32 52.4 20 20 21 6.5 32 14 10 44 40 60 11-
B Vacuum suction port M5 x 0.8 Piping port 2-M5 x 0.8 33 32 10 J depth 1.5 3 5.5 5 12 9.5 +0.030 0 4 Section AA Mounting base side B D +0.030 0 depth 1.5 3 Q QL 11-/22-MXP12-25 Without magnet and switch rail 2-M2 x 0.4 depth 3 8 5.7 3.5 L 6-M4 x 0.7 depth 4.5 20 20 2-M3 x 0.5 depth 3.5 (mm) G H J K L M Q QL S V W Z Model 10 40 68 22 24 29 40 18 15 59 55 76 11-/22-MXP12-15 30 60 98 40 42
Lead Wire Length Lead wire length designation (example) D-A73 L Lead wire length Nil L Z NNote) 0.5m 3m 5m None Note) Applies only to D C type connector switches.
Forced output 60 4.3.1. Forced output conditions 60 4.3.2. Forced output procedure 60 4.3.3. Forced output release procedure 63 4.4. Export Settings 64 4.5. Import Settings 66 4.6. Reading of the initial value 67 4.7. Initialize 68 -1No.EX-OMV0017-C 5. Pairing of wireless unit 70 5.1. Pairing procedure of wireless unit 70 5.2. Registration of dummy Remote 75 6.
ISA2 52.5 l/min 2.5 l/min IS 10 l/min 100 l/min PF2A511 105 l/min 5 l/min ZSM 20 l/min 200 l/min 210 l/min 10 l/min PF2 PF2A521 IF 50 l/min 500 l/min 525 l/min 25 l/min PF2A551 Data
CCT160-l 3/8 3/4 9.5 11 0 30 86 3 28 45 53 88 86 64 88 104 CC 1/2 7 13 2 1 32 120 5 33 65 61 123 116 92 125 139 11/4 3/4 7 20 2 46 185 0 29 93 60 183 180 144 185 202.5 L dimension 600 700 800 Effective oil level stroke (mm) 50 100 200 300 400 500 CCT63-l 228.5 278.5 378.5 503.5 603.5 728.5 s s s CCT100-l 286 386 511 611 736 836 s s s CCT160-l 399 524 624 749 849 949 1049 s s * Hexagon socket
B3 4 15 16 (11) 30.7 L 15.4 ()[820m] 1 2 LE CP B 2 A B-1 L 1 A A-1 6 B B-2 8 8m * 5 B A-2 3 COM-A/COM B-3 A 10m * 4 COM-B/ A-3 B 15m * 3 Shield C 20m * 12 Vcc B-4 13 GND A-4 * 7 A B-5 6 A A-5 * 9 B B-6 8 B A-6 3 4 + B-1 4 A-1 5 + B-3 1 A-3 2 60 - 1 2 5.5 A1 (1) B1 (14) (18) 6.3 17.7 10.2 5 6 (2) (14.2) A6 B6 (3) 1 2 A1 B1 A3 B3 5.7 (4) 15 16 L 30.7 (11) 61 - 15.5 LEC
DC Specification Power consumption (W) Note 1) Temperature rise (C) Note 2) Size Apparent power (VA) Note 1) 2) Temperature rise (C) Note 3) Size Size 1 Size 2 2.5 3 60 60 Size 1 Size 2 2.5 3 60 60 Note 1) Power consumption, Apparent power: The value at ambient temperature of 20C and when the rated voltage is applied.
(V), D-A93(V), D-A96(V) Specifications D-A96 D-A90 In-line D-A90V D-A93 In-line D-A93V In-line D-A96V Auto switch part no.
100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)
TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 12-CY3B6 12-CY3B10 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 12-CY3B50 12-CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2
AC, DC C.O. 7.5 55 6 45 50 42 18 60 37 12 AC Cv converted Av x 10 6 (m 2 ) VX32 AC (Full wave rectification) 50/60 10 8.5 60 1 3 5 0.08 1.5 1.0 0.6 220 1.9 VX311 -00 DC 8.5 60 11 60 9.5 50 1 3 5 0.16 0.5 0.3 220 3.8 VX312 -00 50 55 22 60 47 18 AC 0.6 370 VX3225-00 2.2 0.19 4.6 VX33 1.0 530 VX3325-00 AC (Full wave rectification) 50/60 14 11.5 60 1 3 5 0.24 DC 11.5 60 0.3 0.2 5.8 220 1.0
Minimum measured Maximum measured Minimum measured Maximum measured Minimum measured Maximum measured Part nos. flow rate value [l/min] Part nos. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2
MH*-OMM0056 MHS2-D MHS3-D MHS4-D MHSJ3-D MHSH(J)3-D 1. 23 2. 2-1. 45 3. 3-1. 6 3-2. 67 3-3. 713 3-4. 13 3-5. 14 3-6. 14 3-7. 14 4. 4-1. 14 4-2. 1518 4-3. 1922 4-4. 2326 1 [ ][][] ISO4414*1)JISB8370*2) 1) ISO4414Pneumatic fluid power-Recommendations for the application of equipment to transmission and control systems. 2) JIS B8370 2 1. 2. 3. 4. 3 2 2-1 MHS2 MHS2 -16D MHS2 -20D MHS2 -25D
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
Dimensions Metric size Inch size Model d Weight g D1 D2 L1 L2 L3 Model d Weight g D1 D2 L1 L2 L3 Max. Min. M1 Max. Min.
C 32 H L CBQ2 Standard A93 S B 50 D C CDBQ2 With Auto Switch 32 H L Number of auto switches With auto switch (built-in magnet) 2 pcs. 1 pc.