Set the "load mass" value for the Step Data as close as possible to the load mass mounted onto the table. Avoid changing the load mass whilst the table is moving.
Manual Override Connection and Electrical Circuit Warning Connect each lead wire to the power source side, because of no polarity for DC as well. Black (DC) Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option.
An injury can result. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Burst Pressure Characteristic Curve and Operating Pressure How to Order TUH0644 B 20 5 4 Bundle length Burst pressure MPa Tubing model Length 20m bundle 100m bundle Symbol 20 100 3 2 Color Maximum operating pressure 1 Symbol B W BU N Color Black White Blue Translucent 0 -20 0 20 40 60 Operating temperature C F = (1.8 x C) + 32 1MPa = 145 psi 2 High Pressure Type Series TUH Hard Polyurethane
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel (SUS304) M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel
Applicable model AS-10D AS1002FS AS-20D AS2002FS AS-25D AS2052FS AS-30D AS3002FS AS-40D AS4002FS Part no. Applicable model AS-10L AS1002FS AS-20L AS2002FS AS-25L AS2052FS AS-30L AS3002FS AS-40L AS4002FS Part no.
If it is unavoidable that the tube goes upward, make sure it only goes as far as the position of the auto drain outlet. The drain tube to be prepared should have an O.D. of 0.47 in (12 mm), an I.D. of 0.31 in (8 mm) or more, and be 16.4 ft (5 m) or less in length.
AS-32B AS-34B AS-36B AS-37B AS2002Fm-03A AS-38B AS2002Fm-07A L-bracket AS-20L 2 pcs.
with the PAF5000 series as standard equipment.
Number of fingers and therefore, mg F 2 x With "a" as the safety margin, F is determined as follows: mg F = x a 2 x When = 0.2 When = 0.1 mg F = x 4 2 x 0.2 mg F = x 4 2 x 0.1 = 10 x mg = 20 x mg 10 x workpiece weight 20 x workpiece weight (Note) Even in cases where the coefficient of friction is greater than = 0.2, for safety reasons, SMC recommends selecting a gripping force which
Number of fingers and therefore, mg F 2 x With "a" as the safety margin, F is determined as follows: mg F = x a 2 x When = 0.2 When = 0.1 mg F = x 4 2 x 0.2 mg F = x 4 2 x 0.1 = 10 x mg = 20 x mg 10 x workpiece weight 20 x workpiece weight (Note) Even in cases where the coefficient of friction is greater than = 0.2, for safety reasons, SMC recommends selecting a gripping force which
equipment such as a voltmeter.
Keep the set pressure as low as possible in order to achieve good air saving effect. 6. Cap the valve after adjustment.
(Max. 20 stations) SUP/EXH block assembly mounting position Valve stations Series 3 5 7 02 2 stations SY3000 SY5000 SY7000 20 20 stations Symbol Mounting position U side D side Both sides Special specifications Applicable stations U D B M 2 to 10 stations 2 to 20 stations In case of special specifications, indicate separately on a manifold specification sheet.
(Bracket for centralized lead wire) 28 46 14 16 16 20 19 8 (1.6) 5.5 6 12 22 60 48 2 x 3 6.5 2 x 3.4 4 19.2 2 x 5.5 2 20 ISA3 Series Error Indication Main screen Name Description Measures Supply rated pressure (100 kPa to 200 kPa).
Gripping point L (mm) Gripping point L (mm) DMHR2-20/MDHR2-20 MHR2-20/MDHR2-20 L: Gripping point length (mm) 50 2050 Pressure Pressure 0.6 MPa 0.6 MPa 40 Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F, which is the thrust of one finger, when both fingers and attachments are in full contact with the workpiece as shown
C) In order to generate a clamping force from the state described in step B), insert an additional shim. The thickness of the shim changes depending on the arm length and the operating pressure. Refer to page 13. Please note that the graph should only be used as a guide as there is a tolerance of about 10% in the clamp cylinder body.
Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.