Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
Note 3) ( ) in column W is the dimensions of D-A93.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.
Power supply is AC200V single phase (Note 4) Malfunction RA1 OFF ON MC MC SK EMG stop switch Driver Servo amplifier Servo motor MC (Note 7) MCCB CNP1 1-phase 200 V AC to 240 V AC (Note 11) L1 CNP3 (Note 6) U U L2 Motor V V L3 M [1] W NW P3 (Note 1) (Note 10) P4 CNP2 P+ [2] (Note 2) C [3] D (Note 11) (Note 3) Encoder CN2 Encoder L11 cable L21 (Note 8) Main circuit power supply CN3 EM2 24 V
Operation outside of this range may cause excessive impact, which may result in the damage to the devices. 6 10 Bore size (mm) 6 Operating piston speed (m/s) 0.05 to 0.5 L Allowable kinetic energy (J) 0.012 0.035 100 5st 10st 15st W 100 80 Load weight W (g) 10 10 60 6 Load weight (kg) L 40 1 W 20 0.1 00 5 10 15 20 0.01 0.01 1.0 0.1 Eccentric distance L (mm) Maximum speed (m/s) 10 300 5st
Material: Carbon steel Dd9 d L Part No. m t l 0.040 0.076 CD-S02 CD-S03 20/25 32/40 8 C8 type for pivot 7.6 24.5 19.5 1.6 0.9 0.040 0.076 10 C10 type for pivot 9.6 34 29 1.35 1.15 Applicable bore size 20 25/32 40 Part No.
ZS-20-A 16 NPN open collector 2 output w/o analog output, 3 turns adjustment With lead wireZS-20-5A17 NPN open collector 2 output w/o analog output, 200 degrees adjustment Note) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length 18 NPN open collector 1 output w/analog output, 3 turns adjustment 0.6 m Nil Ex.) ZSE1-01-15CN1 pc.
1 AS-FP w Meter-out type Meter-in type AS-FM AS-D Universal type AS-T Seal method: Gasket seal For Uni thread ASP !1 !1 r r ASN q q !2 !2 AQ y y ASV !3 w t t AK w i i VCHC o ASR ASQ o !0 e !0 e u u !4 !4 Meter-in type Meter-out type Component Parts Meter-in type Meter-out type No.
motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W) Connect the motor ground terminal to the driver ground terminal.
[Tightening torque: 0.90.1N m (0.670.07ftlb] 3 Attach brackets to the manifold bases. {when equipped with brackets} [Tightening torque: 0.90.1N m (0.670.07ftlb] Note) Manifold station additions can be made in units of 2 or 3 stations.
TYPe d beains 3 tandard s 'qo ' okd ( fYnI ro r r 2.9r 2 3 . 40' I lo , ?
ZP3PA-T1JT-7A-X2 ZP3P 20 JT2 SF M ZP3PG20JT2SF-M-7A-X2 21 ZP3P-20JT2SF-WM ZP3P 32 JT2 SF ZP3PG32JT2SF-7A-X2 48 ZP3P-32JT2SF-W ZP3PA-T2JT-7A-X2 ZP3P 32 JT2 SF M ZP3PG32JT2SF-M-7A-X2 48 ZP3P-32JT2SF-WM ZP3P 20 JT5 SF ZP3PG20JT5SF-7A-X2 23 ZP3P-20JT5SF-WG ZP3PA-T1JT-7A-X2 ZP3P 25 JT5 SF ZP3PG25JT5SF-7A-X2 25 ZP3P-25JT5SF-WG ZP3P 32 JT5 SF ZP3PG32JT5SF-7A-X2 54 ZP3PA-T2JT-7A-X2 ZP3P-32JT5SF-WG
fluid outlet 0.6 60 Pressure [MPa] 0.5 50 Lifting head [m] Usable flow rate range 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow[L/min] Fig. 8-11 Pump capacity(HRL300-A-20 CH1) 8.5.4 HRL-A-20CH2 0.6 60 0.5 50 Lifting head [m] Pressure [MPa] 0.4 40 Usable flow rate range Circulating fluid outlet 0.3 30 0.2 20 Chiller display
(Mounting position: Horizontal) W 1000 500 400 Allowable lateral load W (N) 300 Allowable kinetic energy 200 Piston speed 200 180 200 100 180 Piston speed Allowable kinetic energy 20 to 400mm/s 12.4J 50 40 30 (m1 + m2) V Kinetic energy E (J) = 2 m1: Weight of moving cylinder parts kg m2: Load weight kg V: Piston speed m/s 20 10 0 20 40 60 80 100 120 140 160 180 200 220 260 240 280 300 Kinetic
Cylinder Rated measurement range 0 to 999 times Count timing Measurement start Increase Count (1 time) Increase Count (2 times) M Compact: 40 (Width) x 110 (Height) x 20 (Depth) mm M With backlight M With auto power-off function M Lightweight: Approx. 65 g (Body)/25 g (Sensor) If a button is not operated for 15 min. or more, the power supply will turn off automatically.
Reference Reference 6.1 Specification table Model IDF100F-30 IDF125F-30 IDF150F-30 Item -W -W -W Fluid Compressed air Operating range Inlet air temperature oC 5 to 60 Inlet air pressure MPa 0.25 to 1.0 / 0.15 to 1.6 for option K Ambient temperature (humidity) oC 2 to 45 (Relative humidity 85% or less) Facility water pressure MPa 0.2 to 0.98 Facility water inlet temperature oC 5 to 40 50Hz
M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46 60 70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 P (Piping port) Model Mounting nuts (2 pcs.) are shipped together.
Altitude [m] 1. Max. ambient 2. Cooling capacity temp.