SMC Corporation of America
Elite Part Number Search
Search Results "CYP32-500"

(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.

(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M or more between external terminals and F.E.

(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.

General Specifications Table 4-1 EX245 series general specifications Item Specification Rated voltage 24 V DC +20% -15% Supply interruption for no loss of function 1 ms maximum Protection class IP65 (when fully installed or fitted with protective cover) (complies with IEC 60529) Insulation resistance 10 Mohm @ 500 VAC between FE and all accessible terminals to IEC 61131-2.

[P_2] Set value of OUT2 500 L/min 1000 L/min Brown DC(+) Brown DC(+) 1 1 IO-Link status indicator light LED is ON when OUT1 is used in IO-Link mode.

(Custom range) Relationship between analogue input and digital display Set value A B 200 0 L/min 200 L/min 500 0 L/min 500 L/min 1000 0 L/min 1000 L/min 2000 0 L/min 2000 L/min 3000(Default) 0 L/min 3000 L/min 6000 0 L/min 6000 L/min 12000 0 L/min 12000 L/min 16000 0 L/min 16000 L/min 20 0 L/min 20 L/min USEr Input value (setting) Input value (setting) -31No.PF-OMU0007-D Press

Max. 1 NL/min 10 NL/min PF2A710 3.5 CFM x 10-2 35.0 CFM x 10-2 5 NL/min 50 NL/min PF2A750 18 CFM x 10-2 176 CFM x 10-2 10 NL/min 100 NL/min PF2A711 3.5 CFM x 10-1 35.5 CFM x 10-1 20 NL/min 200 NL/min PF2A721 7 CFM x 10-1 71 CFM x 10-1 50 NL/min 500 NL/min PF2A751 18 CFM x 10-1 176 CFM x 10-1 : Analogue output is based on the rated flow range at normal condition.

. -20No.PF-OMO0010-C Specification Specifications Specifications of body Model PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Applicable fluid Air and N2 Fluid temperature 0 to 50 C (no condensation or freezing) Flow Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 L/min L/min L/min L/min L/min Pressure Rated pressure range -50 kPa to 0.5 MPa -50 kPa to 0.75 MPa Proof pressure 1.0

500 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T and MT are selected.

500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60Hz 50Hz Fig. 9-5 Heating capacity(HRS050-A-20-(BJM)) 9.5.2 HRS050-W-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 5 20 25 32 40 1500 1500 5 20 25 32 40 Heating capacity [W] Heating capacity [W] 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35

5 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 60Hz 50Hz Fig. 9-5 Heating capacity(HRS060-A-20-(BJM)) 9.5.2 HRS060-W-20-(BJM) 2000 2000 Ambient Ambient temperatur temperatur Heating capacityW Heating capacityW 1500 e e 1500 40 32 25 20 5 40 32 25 20 5 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating

By default: 500 hour Usage time Displays the usage time of a dustproof filter. 5 Dustproof 1 to 9 hour The Maintenance reminder is issued if the usage time has reached the hours specified by the user.

The value used for consideration should not be the very limit for the safety. 6.2.1 Performance of HEC006 1) Cooling capacity Radiating Water Temp.20 oC Radiating Water flowrate8L/min 1500 Cooling capacity W 1000 Fluid: Water 500 Fluid: Fluorinert FC-77 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig. 6-1 Cooling capacity of HEC006 2) Heating capacity Radiating Water Temp.20 oC

When the circulating fluid temperature is low, do not operate it at a low 500 500 flow rate. It may freeze circulating fluid in the product when used at low temperature and low flow rate. Dec Z yZ ZZ AZ BZ CZ DZ . 400 400 This manual provides the following symbols in addition to Danger, 300 300 This unit does not use parts that meet the SCCR specifications.

Changes the input current to open or close the actuator fully with (500) Forced fully close increased force. Set to ON (fully closed = 0.5% and fully open = 99.5%) at the / fully open time of factory shipment. (600) Dead band Changes the deviation where the dead band is applied.

(at 25 oC) Enclosure IP65 Withstand voltage 500 VAC, 1 minute, Between lead block and case Insulation resistance 100 M or more (at 500 VDC) Between lead block and case Environ mental Operating temperature range Operation: -10 to 60 oC, Storage: -20 to 70 oC (No condensation or freezing) Operating humidity range Operation, Storage: 35 to 85%RH (No condensation) Standard CE marked (EMC directive

No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12

. -7No.D-S-OMK0010-H Model Indication and How to Order D-M9 A Output type Lead wire length and termination Symbol Specification Symbol Specification N 3-wire, NPN NIL 500 mm (Half strip) P 3-wire, PNP M 1000 mm (Half strip) B 2-wire L 3000 mm (Half strip) Z 5000 mm (Half strip) Electric entry SAPC 500 mm (M8 3-pin pre-wire) Symbol Specification SBPC 500 mm (M8 4-pin pre-wire) NIL In line

WaitTime_Setting int 500 WaitTime setting after valve operation (Unit: ms, Range: 0..1000ms) It is a wait time value after the valve for opening gripper is energized. Set an appropriate value according to the opening speed of the gripper by adjusting the opening of the metering valve.

ms01000ms TimeOutVal_Setting int 500 ms01000ms 22 - Component CLOSE Component Success: Close and Check Signal False Close and Check Signal True ON Fail: Open and Check Signal true Wrong_value: WaitTime Setting TimeOutVal_Setting bool false / Close and Check Signal true ON false WaitTime Setting int 500 ms01000ms TimeOutVal_Setting int 500 ms01000ms 23 - 5-4 1. 2. 3. 4. 1.(