100% 10 , 16 20 , 25 540 40% 100% 2150 80% 100% 1120 60% 100% 10L , 16L 510 50% 100% 3150 70% 100% 20L , 25L 520 40% 100% 2130 50% 100% [mm/sec] () 2130 50% 100% 520 40% 100% [mm/sec] () 4150 50% 100% 540 40% 100% 3150 80% 100% 1130 60% 100% 510 40% 100% 22 - 150% LEHZJ 1) (SVON ) 2)CN1 EMG() a)SVRE SETONON SVRE OFF SETON ON b) SVREON SVREON c) SVREON
When the positioning pinhole is used for mounting a body, select a positioning pin with an appropriate length. Caution MXH 3.
Check that this matches the controller. (2) Check Parallel I/O configuration matches (NPN or PNP) Controller Electric actuator LEFS25FB-100 LEFS25FB-100 NPN (1) (1) (2) 8 No.JXC-OMY0002-A 2.4 Option 1 Actuator cable[5 m or less] (1) (2) A B-1 Brown 2 A A-1 Red 1 Cable length (L) B B-2 Orange 6 B A-2 B-3 A-3 Yellow 5 1.5m 1 Green 3 3m 3 Blue 4 Shield (3) 5m 5 Vcc B-4 Brown 12 GND A-4 Black
Controller Electric actuator LEFS25B-100 LEFS25B-100 9 - 2.4 Option (1)Actuator cable (5m or less) --Cable color Terminal no. signal Terminal no. Brown 2 A B-1 Red 1 A A-1 Cable length (L) Orange 6 B B-2 Yellow 5 B A-2 1.5m 1 Green 3 COM-A/COM B-3 3m 3 Blue 4 COM-B/ A-3 Shield 5m 5 Cable color Terminal no.
(When L/A IN LED is OFF.) (2)Check that the connectors of L/A IN and L/A OUT communication cables are connected and there are no broken wires. (3)Keep noise sources away from the communication cable. L/A IN and L/A OUT LEDs are OFF. LINK has not yet been established. 11 : The L/A OUT LED will be OFF if the BUS OUT connector is not used.
This is accomplished by interfacing a stepping motor and gear box to a modified 800 or 900 series subminiature regulators. A calibration report included with every unit provides a detailed test data including a scale factor that corresponds to a slope that will yield a open loop accuracy including linearity, repeatability and hysteresis, of < +/3% FS.
(A) 4 (B) 2 FPG 1 (P) 5 (R1) 3 (R2) Coil rated (A) 4 (B) 2 1 2 3 4 9 100 VAC 200 VAC 24 VDC 12 VDC FIG 1 (P) 5 (R1) 3 (R2) Other voltages Option For other voltages, please contact SMC separately.
ISO size 1 Series VQ7-6 ISO size 1 Max. 10 stations 0.43n + 0.49 (n: Stations) 1/4 3/8 Bottom Note) When equipped with control unit, 1 or 2 stations are used for mounting. 3-10-11 Series VQ7-6 DIN Terminal Type VV71-100 80 100 2n-1/4, 3/8 80 23 37 9 14 9 15 U side U side Manual override R4.5 R4.5 Indicator light P = 43 53.5 P = 43 53.5 B B B B 9 9 B 23 20 SMC SMC SMC 9 A PA A B B A PA A B
Discharge Volume 1500 200 1500 VXF(A)28B VXF(A)23A VXF(A)27B 150 Discharge volume (L) Discharge volume (L) Discharge volume (L) 1000 1000 VXF(A)25A, B 100 VXF(A)26< 500 500 VXF(A)22A 50 VXF(A)24A VXF(A)21A 0 0 0 0 500 1000 1500 Piping length to the pilot valve (mm) 0 500 1000 1500 Piping length to the pilot valve (mm) 0 500 1500 1000 Piping length to the pilot valve (mm) 8 Series VXF2/VXFA2
m/s2 Fluid and fluid temperature Valve specifications Rated voltage DC 12 V, 24 V Allowable voltage fluctuation 10% of the rated voltage Allowable leakage voltage 2% or less of the rated voltage Power consumption (Holding)*4 2 W 3 W 3 W Glossary of Terms Coil specifications Inrush current 12 VDC 1.25 A 2 A 2 A 24 VDC 0.63 A 1 A 1 A Temperature rise*5 25C 25C 25C 1 Leakage: The value at a
Required ventilation rate [m3/min] Model Heat radiation amount [kW] Differential temp. of 3C between inside Differential temp. of 6C between inside and outside of installation area HRR010-A Approx. 2 40 20 HRR012-A Approx. 2 40 20 HRR018-A Approx. 4 70 40 HRR024-A Approx. 5 90 50 HRR030-A Approx. 6 100 60 HRR050-A Approx. 10 140 70 and outside of installation area Voltage dV dt = Voltage
(A) 2 (A) 2 12 12 Standard 1 (P) 3 (R) 1 (P) 3 (R) i (A) 2 (A) 2 2(A) 3(R) o For vacuum 12 12 3 (R) 1 (P) 1 (P) 3 (R) X 1(P) For vacuum u y t r e w q i 2(A) 3(R) o X Component Parts No.
A B Hs A B Hs Hv Hv Hv Hv 12/16/20 12/16/20 Hs Hs 25/32/40 25/32/40 Proper Auto Switch Mounting Position Solid state switch Bore size (mm) 2-color indication solid state switch Reed switch D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV A B C A B Hs Hv A B A B Hs Hv A B C A B Hs Hv C 15.5 15 20 20 15 19.5 19.5 19.5 19.5 46 46 46 46 18 13 15.5 35.5 42 31.5 42 31.5 12 17 17 22 22 17 21 21 21 21 47.5 47.5
Install a suitable filter (strainer) immediately upstream from the valve. As a general rule, use 80 to 100 mesh. When used to supply water to boilers, substances such as calcium and magnesium which generate hard scale and sludge are included.
at point A when a load is applied to point A 100 mm away from the rotation center.
A A A (Pitch) P=17 (Pitch) P=16 M5 x 0.8 (A port) 1/8 (A port) 8.5 8.5 14.5 14.5 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Station 2 52 43 53 44 Station 20 340 331 359 350 3 68 59 70 61 4 84 75 87 78 5 100 91 104 95 6 116 107 121 112 7 132 123 138 129 8 148 139 155 146 9 164 155 172 163 10 180 171 189 180 11 196 187 206
(mm) How to view the diagram (ex: when using a 100 to 450st cylinder): Draw a line perpendicularly from the cylinder stroke of 450 to the point at which it intersects the (curve) cylinder bore size of 100, and extend it to the left to obtain the displacement of approximately 5,300cm3. Then, select a converter with a larger capacity. The converter will be 160 to 300.
A A A A A 98.2 5.5 A B A B 58.9 17.5 29.6 56.3 12.2 Manual override Press and turn for the locking type.
91.9 A A A A B A B A B A B A Dimensions are the ones for SV1300--.
Flow coefficient: When 100% of water flows at 1 mm2/sec, the flow coefficient indicates that 85% flows at a kinematic viscosity of 100 mm2/sec. Flow rate (L/min) 50 A Bag Filter FGF Series Construction FGF1 FGF3-40 FGF5-60 Air release Nut Air release valve Pin q FGD Davit for cover Spring washer t u !