EXH system Common SUP system Common, Individual Vacuum Ejector Specifications Fluid Air 0.7 MPa 84 kPa 0.2 to 0.55 MPa 0.25 to 0.55 MPa 5 to 60 C 5 to 50 C Main valve Pilot valve Poppet VJ114, VJ324M Maximum operating pressure Maximum vacuum pressure Without valve With valve Without valve With valve Supply pressure range Operating temperature range Maximum air suction volume increased

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Cylinder with lock, CNG series, Double acting, single rod, Cushion: rubber bumper, air cushion, Bore sizes

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Cylinder with lock, CNG series, Double acting, single rod, Cushion: rubber bumper, air cushion, Bore sizes *

or less (24 VDC) P2: Analog output 1 to 5 V Allowable load resistance 100 k or more P6: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) 339 LLB Series Refer to the operation manual for how to set and to operate.

(3000) 56.5 600 (3000) 49 8.5 47 47 3.5 3.5 8.5 2-3.5 Mounting hole T1: NPTF 1/8 01: R 1/8 M5 x 0.8 depth 5 Piping port M5 x 0.8 depth 5 Piping port 2-3.5 Mounting hole T1: NPTF 1/8 01: R 1/8 13 13 16-6-5

AP100 Port size B 2 1/4 3 3/8 Note) EXH port: 1/4 Built-in regulator EXH port: M5 Solenoid valve EXH port: M5 L-bracket C * Bracket is included. 957 ITVH2000 Series Standard Specifications Model ITVH2000 Minimum supply pressure Whichever is higher: 0.5 MPa or the set pressure + 0.2 MPa Maximum supply pressure 3.0 MPa Set pressure range Note 1) 0.2 to 2.0 MPa Power supply Voltage 24 VDC 10%

Cooling capacity: 600 W, 1200 W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 200 ~ 220 VAC, 50/60Hz ; Circulating fluid: Clear water or fluorinated fluid ; Standards: CE

Cooling capacity: 600 W, 1200 W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 200 ~ 220 VAC, 50/60Hz ; Circulating fluid: Clear water or fluorinated fluid ; Standards: CE

588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Adsorption nozzle port 0X: M5 x 0.8 0XY: M6 x 1 Vacuum supply port 0X: M5 x 0.8 0XY: M6 x 1 58 51 50 PV 6.5 10.2 8 10 17.8 11 5.5 2-3.3 Mounting hole Connector type: ZSP10X C Adjusting needle ADJ Pressure sensor Vacuum supply port 20 08 Adsorption nozzle port 7 48.3 Lead wire length 600 (3000) Adsorption nozzle port 0X:

(dimension reduced by 12mm to 26mm) (mm) Series 40 25 16 MY2C MY2H MY2HT MY1C, MY1H 58 37 28 84 54 40 Mechanical Joint Rodless Cylinder/Cam Follower Guide Series MY2C MY2 C Cam Follower Guide Improved guide performance enhances dynamic load capacity over other P/A cylinder Long strokes 60 M 3 30 50 Series MY2C cylinder is now available in long strokes up to 5000mm.

ZSE40(F)/ISE40W1 2-M4 x 0.7 thread depth 4 20 30 Rc 1/8 MPa 7 19 20 30 OUT2 OUT1 SET 6.5 R 6.4 18.35 Atmospheric release port Lead wire length 600 (3000) 3.5 12.4 7.8 7 2.5 2.6 30 15.2 42 10.7 4 6 For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to Specific Product Precautions 4 on the back cover for details.)

(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.

L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max. Model Port size Model Port size 120 150 AS800 AS900 1 1 , 2 74 93 204 262 192 250 80 94 AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 15-9-33

Model (Made to Order) Model Pressure rangeNote) Indication unit Connection thread Note MPa G46-2-01 to 02-C/ C1 G46-4-01 to 02-C/ C1 G46-7-01 to 02-C/ C1 G46-10-01 to 02-C/ C1 G46-2-01 to 02M-C/ C1 G46-4-01 to 02M-C/ C1 G46-7-01 to 02M-C/ C1 G46-10-01 to 02M-C/ C1 G46-4-02-X30 G46-10-02-X30 G46-2-02M-X4 G46-4-02M-X4 G46-7-02M-X4 G46-10-02M-X4 G46-2-02M-C/ C1-X4 G46-4-02M-C/ C1-X4 G46-7-02M-C

width across flats) AS-D AS-T ASP ASN AQ ASV AK Metric Size Inch Size VCHC Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.

(P.124) Wetted Parts Material S H Wetted Parts Body Surface finish Spring Diaphragm Poppet Seat Hastelloy C-22 Electropolish Inconel 600 316L SS secondary remelt Electropolish + Passivation 316L SS Elgiloy Hastelloy C-22 PCTFE 316L SS PCTFE (Option: Vespel) 106 Diaphragm Valve for Ultra High Purity Air operated type (For high pressure and high flow) Series AP3130 & 3113 AZ AK KT BP Diaphragm

For the value range and the resolution (value of each single LED), see the following table : Parameter Description Display Value range Resolutio Set n value Synchronous flashing Set-point Activation of the hot-gas 2.0 6.5 C 0.5 C 3 C solenoid valve LED + LED Synchronous flashing TON Activation time of the 1 10 sec 1 sec 2 sec condensate drain solenoid valve LED + LED Non-synchronous flashing

HT135)50 to 140F (10 to 60 C) (no condensation)600 W (Clear water), 400 W (Fluorinert FC-3283) Note 2)900 W (Clear water), 600 W (Fluorinert FC-3283) Note 2)?0.018 to 0.054F (?

Maximum load impedance: Power supply voltage 12V: 300 Power supply voltage 24V: 600 Minimum load impedance: 50 Reduce/Increase supply pressure to within the regulating pressure range. Applied pressure error Brown DC(+) Supply pressure is below the minimum regulating pressure.