Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
4.8 16.6 12.2 1.5 0.7 Double knuckle joint Mounting nut Rod end nut Knuckle pin and snap ring are packed together. d d MM ND hole H10 Shaft d9 L RR1 C C +0.2 0 NX +0.2 0 U1 A1 L1 12 7 B H B H Material: SUS304 Material: SUS304 Material: SUS304 Part no.
E s .9 6 5 o 25 50 75 Inpul siqnal (%F.s.) l 25 50 75 Inpul signal (%F.S.)
force (Max.) 550 860 1340 2140 Series Variations Bore size (mm) Cushion Standard stroke (mm) Lock direction Manual release Model 10 15 20 25 50 75 100 Non-locking type Front lock CBQ2 Rubber bumper 32, 40, 50, 63 Rear lock Locking type Series CBQ2 How to Order B 50 D C 32 H L CBQ2 Standard A93 S B 50 D C CDBQ2 With Auto Switch 32 H L Number of auto switches With auto switch (built-in magnet
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
D) In the state of C), adjust shim w so that the arm side block contacts the workpiece. E) Exhaust the air while in the clamped state, and confirm that the clamp arm does not open. 8 CKZT -X2797 -X2798 Relation between shim thickness and clamping force Use this figure as a guide, as there is a tolerance of about 10% in the clamp cylinder body.
1.5 B D E L 4-H Valve mounting hole F Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D E F G H J L Valve model Bracket part no.
Grommet, Lead wire length 300 mm C Conduit D DIN terminal With surge voltage suppressor VP 200 VAC, 50/60 Hz Port size 110 VAC, 50/60 Hz 02 1 4 4 AC: Can be attached to Grommet, Conduit, Conduit terminal.
D. Holding Force O. D. Holding Force MHKL2-12D MHKL2-12D 20 25 Pressure 0.6MPa Pressure 0.6MPa 20 Holding force N Holding force N 15 0.5MPa 0.5MPa 15 0.4MPa 10 0.4MPa 10 0.3MPa F F 0.3MPa 5 5 0.2MPa 1N = 0.2248 lbf = 0.102 kgf 1MPa = 145 psi = 10.2 kgf/cm2 0.2MPa 0 0 50 50 10 20 30 40 10 20 30 40 Holding point L mm Holding point L mm O. D. Holding MHKL2 series I. D.
L-type block (75) (50) W R P Q Port size Weight (kg) d K W Y AE (mm) (75) (50) W J W (mm) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 47 47 47 50 50 50 50 50 70 70 70 85 85 85 105 105 9 9 9 9 9 9 9 9 62 62 62 65 65 65 65 65 3.5 3.5 3.5 6.2 6.2 6.1 11.9 11.9 Port size Weight (kg) E J P Q Port size Weight (kg) E 69
VAC ERR ERR ERR ERR Note) Stations are counted starting from the D side. 50 56 D side U side 1 2 . stations 50 9 3 (8) 6.5 6.5 Dimensions in inch are noted in parentheses. 1 1 82 89.5 SUP, VAC z port 3 3 (6, 1/4") 40 40 EXH, ATM c port 25 25 (6, 1/4") 2 2 2 5 5 OUT x port (4, 5/32") Breathing hole Note) 3.7 (M3 x 0.5) Note) For dimensions of the cable connector, refer to single unit on page
(C ) Temp. conditions Power source Vacuum 60 10 Air Response Characteristics 40 AC/DC Maximum Minimum AC/DC 20 Response time (msec) Switching Signal ON OFF Model Power source Tightness of Valve (Leak rate) 60 or less DC VX31 40 or less 50 or less AC 40 or less 40 or less DC 50 or less 40 or less AC 50 or less 60 or less DC 60 or less 40 or less AC 50 or less Seal material Fluid Air Liquid
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.
---Ht-t---t-+-H I--i IN o I w c.
PFMB7501/7102/7202 2x A B D E F H K L N PFMB7501/7102 70 30 43.7 37.2 15 14 26 18 13.6 PFMB7202 90 35 49.2 42.7 17.5 24 31 28 16.8 S T U V W PFMB7501/7102 24 22 32 40 50 PFMB7202 30 30 42 48 58 -67No.PF-OMP0001CN-F (ZS-33-D) (ZS-33-F) -68No.PF-OMP0001CN-F Revision history A B C D E F [September 2016] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81
VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177
100 120 140 160 180 200 220 240 260 Operating temperature C Inch size T T 20 TILM01 N 1.2 Max. operating pressure MPa D IDK 1.0 Tubing designation Length per roll Symbol 10 20 50 100 16 33 2S 0.8 Type Length 10 m 20 m 50 m 100 m 16 m (50 ft) 33 m (100 ft) 2 m 0.6 Color indication F Symbol N R BU B Color Translucent (Material color) Red (Translucent) Blue (Translucent) Black (Opaque) 0.4 Roll
Auto Switch Proper Mounting Position (Detection at Stroke End) Electrical entry direction: Inward Electrical entry direction: Outward D B A C B D-Z7Z8, D-Y7W D-Y5, D-Y7 D-Y6, D-Y7V D-Y7WV D-Y7BA Bore size (mm) A C 16.5 (15) 23.5 (22) 34 (32.5) 46 (44.5) 46 (44.5) 56 (54.5) D 0.5 (1) 3.5 (2) 0.5 (1) 3 (1.5) 5 (3.5) 5 (3.5) C 18 25 35.5 48 48 58 D 2 5 2 4.5 6.5 6.5 C 10.5 17.5 28 40 40 50 D
D-M9(V) D-M9W(V) D-M9A(V) Auto switch mounting bracket part no.