IR3000 : G43-2-01 G43-P2-N01-X30 IR3010 : G43-4-01 G43-P4-N01-X30 IR3020 : G43-10-01 G43-P10-N01-X30 Set pressure Thread type NIL:Rc F:G 0: 0.01~0.2MPa 1: 0.01~0.4MPa 2: 0.01~0.8MPa N:NPT (Note 3) The pressure gauge is not attached and becomes bundled shipment. 4. Marking on product Product name plate MAX.SUP.PRESS. MAX.SUP.PRESS. MAX.SUP.PRESS.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WEN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (16 points) 2 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#B (8 points) 0 1 EX600-DY
Content 0 to 5 A channel number of 0 to 63 is displayed. 6 Input/Output Type: 00 = Reserved, 01 = Input, 10 = Output 7 -68No.EX-OMN0028-B Diagnostic type Bit No.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
[February 2017] H: Contents revised in several places. [July 2018] I: Contents are added. [May 2019] J: Contents revised in several places.
Dimensions (Hexagon width across flats) Dimensions Min L1 H Screw D D Model Max 20.5 20.5 30 34.2 37 49 ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 8 8 12(12.7) 17(17.5) 19 24(23.8) 23.3 23.3 35 39.2 42 54 10 10 15 20 25 30 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 Screw D Note) (in parentheses) are the dimensions of NPT screw specifications. Caution Be sure to read before handling.
Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-l02 : E4-l03 : E4-l04 1 4 3 8 1 2 1 4 1 2 : E6-l06 : E6-l10 3 4 1 : E5-l04 : E5-l06 : E3-l02 : E3-l03 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) l in the gauge part number (e.g.
ISA11-4L-01BG ZSE2 ISE2 ISA15-1-01G ZSP ISl ZSM Accessories (Optional) PFl Bracket ISA-1-A Gauge G33-3-01 DIN rail ISA-2-1 to 7 IFl Gauge/G33-3-01 Bracket /ISA-1-A DIN rail/ISA-2-1 to 7 Material: SPC (Nickel plated) Material: Aluminum 10 hex. 100 110 q w e r t L 90 10 25 5 4-4.5 7.5 30 R1/8 34 42 28 4.5 35 27 9 16.5 13 5.6 L Applicable model Part No. 105 140 175 210 245 280 315 Description
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
AXT510-32A AXT503-23A Flow control interface Pressure gauge G36-10-01 G36-10-01 Model Selection Applicable cylinder bore size: 25 to 125 For model selection, refer to Selecting Electro-pneumatic Proportional Valve on page 14-9-20. 14-9-18 3 5 Port Electro-pneumatic Proportional Valve Series VER2000/4000 How to Order Nil Port size Without sub-plate 02 03 1 4 3 8 F.R.L.
Direct Operated 3 Port Solenoid Valve Series VX31/32/33 For Air / Single Unit How to Order (Single Unit) For Air Specifications For Water For Oil For Steam For Vacuum Pad Construction Dimensions 1 G G 5 1 VX DC 1 4 31 01 VX 1 4 31 01 R1 AC/Class B coil (Built-in full-wave rectifier type) Model Refer to Table (1) shown below for availability.
0.5 to 10 psig (0.0034 to 0.07 MPa) 1 to 30 psig (0.007 to 0.2 MPa) 5 to 100 psig (0.034 to 0.7 MPa) 15 to 200 psig (0.1 to 1.4 MPa) 15 to 300 psig (0.1 to 2.1 MPa) Code No code P 01 02 10 20 30 Connections (Inletq, Outletw) 3) Panel mounting hole: dia. 1.42 inch (36.1 mm).
Ground wire (1.5 m)/Accessories IZH-A-01 High-voltage measuring handle/Option IZH-C-01 Soft case/Accessories IZH-B-01 High-voltage measuring handle Ground wire Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during high-voltage measurement when there is a possibility of personnel coming in contact with electricity.
Note Bracket VK300-43-2A With screw Body ported VK332 1 G M5 1 G 01 VK334 Base mounted CE-compliant Q CE-compliant Nil Port size Note) Applicable only for DIN terminal type 01 (With sub-plate) Nil Without sub-plate 1 8 Valve option Light/Surge voltage suppressor CE-compliant Nil V Y W E Standard type For vacuum Nil None S With surge voltage suppressor For low wattage For vacuum/low wattage
D only) Port size CE-compliant G 01 (With sub-plate) Nil Without sub-plate NPT S 1 8 NPTF Z Note) Applicable only for DIN terminal type Since the indicator light is built in the connector, thus, DOZ is not available.
$% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !
$% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !
(October 1999) Vacuum ejector system Manifold ZZQ108A-B S C-A (1) (2)(3) (4) (3) Vacuum release pressure supply port (PD port) (1) Number of stations B None (Release pressure is 01 1 stations supplied from the P port.) 02 2 stations C Note 1) Provided (Breaking pressure: Supplied : from D port) 08 8 stations Note 1) If the standalone product does not have the energy saving function, select
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,