V 10 100 10 14-9-3 4 Series VBA1110 to 4200 Construction/Principle VBA1 VBA1110/2100/4100 Governor Drive chamber A Booster chamber A Governor Drive chamber A Drive chamber B IN (Inlet side) IN (Inlet side) Booster chamber B Drive chamber B Piston Rod Piston Booster chamber A Piston Switching valve Check valve Booster chamber B Check valve Switching valve OUT (Outlet side) OUT (Outlet side
Note Bracket B and the bracket assembly make up one set.
Tighten the connector by hand. -23No.PF-OMV0006-B Examples of Internal Circuit and Wiring NPN output type Max.28 V, 80 mA Internal voltage drop 1 V or less PNP output type Max.80 mA Internal voltage drop 1.5 V or less Used as IO-Link device : Numbers in the figures show the connector pin layout.
C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C D 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0009CN-F PF3W504/520/540/511 2X A AA B DD E F G H
Piston rod movement direction: Standard Set point: Set Signal name Input / Signal transition Output PWR DC24V 24 V (Power supply) 0 V E-STOP ON (Emergency stop) OFF 20mA Sig-in (+/-) (Analog input signal) 4mA 0mA 20mA Extended end direction Pos-out (Analog output signal) Retracted end direction 4mA 0mA (A) (B) (C) 51 8.
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
PAO /PAO 17 18 Phase-A signal Encoder output pulse signals for two-phase pulse train with PBO /PBO Phase-B signal 90 phase differential 19 20 PCO /PCO 21 22 Phase-Z signal Origin pulse output signal Signal ground Connects to the 0 V pin on the control circuit of the PC or PLC ... etc.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -36No.PS-OMV0004-H [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
Load voltage Lead wire length (m) Applicable load Type Special function Electrical entry Indicator light Wiring (output) Direct mounting 0.5 (Nil) 3 (L) 5 (Z) DC 3-wire (NPN) F8N U U u Solid state switch IC circuit Relay PLC 5 V 12 V Grommet (Perpendicular) 3-wire (PNP) F8P Yes 24 V U U u F8B 2-wire 12 V U U u Lead wire length symbols: 0.5 m . Nil (Example) F8N 3 m .
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -39No.PS-OMV0009-E [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
(The above graph shows the value when V port is 8.) Port size Flow rate characteristics of V to PV (Vacuum side) PV port V port C[dm3/(sbar)] b Cv 6 8 0.39 0.14 0.09 11.3. Vacuum Release Flow Rate Characteristics The graph shows the flow rate characteristics at different supply pressures when the vacuum break flow adjusting needle is open from the fully closed state.
Piping adapter Spacer with Bracket Mounting Position Dual residual pressure release valve (-X538) Dual residual pressure release valve with soft start-up function (-X555) (Max. 10) 201.8 82.9 (14) (14) 201.8 (Max. 10) 82.9 IN OUT IN OUT d c b a d a b c Model a b c d Note Model a b c d Note VP544-5DZ1-03-X538 33.9 57.2 95.7 220.7 AW30-03G-A Y300T-A E300-03-A VP544-5DZ1-03-X555 33.9 57.2 129.2
) 0.6 to 5 V 2.5% F.S. 1 to 5 V 2.5% F.S.
locking) Section B-B Section B-B Section A-A *Above figure show the unlocked state.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -37No.PS-OMY0007-A [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
Clevis Y-O5A Y.O5A Y-O8A Y-1OA Fod Clevis Pin CDP.3 CDP-3 CDP-5 CDP-6 Rod Nul NT.05 NT-05 NT.O8 NT-10 Mounlinq Brackel Clevis Pln CDP.3 CDP.4 CDP.6 CDP-7 SERIES CP CYLINDER POSITIONING ASSEMBLY DIMENSIONS CPA1 B N vr/o Boot with Boot' BORE B D E K L M MM N s H z.
Example: Analog output = 1 to 5 [V] F .S. = 5 [V] 1 [V] = 4 [V] 3 [% F .S.] = 4 x 0.03 = 0.12 [V] The output error induced by the temperature change can be as much as 120 [mV].
JIS B 9960-1: Safety of machinery Electrical equipment of machines Part 1: General requirements JIS B 8433-1:2007: Robots for industrial environments Safety requirements Part 1: Robot 2) Labor Safety and Sanitation Law etc.
ON: Red light emitting diode Indicator light Auto Switch Weight Table Unit: g D-F9N(V) D-F9P(V) D-F9B(V) Model Auto Switch Internal Circuits 0.5 7 7 6 lead wire length (m) D-F9N, F9NV 3 37 37 31 5 61 61 51 DC (+) Brown Main circuit switch Main circuit switch OUT Black Auto Switch Dimensions D-F9 Switch mounting screw M2.5 x 4l Slotted set screw DC () Blue 2 Indicator light D-F9P, F9PV 2.7
ZPG10B-7A-X2 7 7 7 8 ZP10B ZPT2-7A-X2 ZP 13 B ZPG13B-7A-X2 7 8 8 8 ZP13B ZP 16 B ZPG16B-7A-X2 8 8 8 9 ZP16B ZP 20 B ZPG20B-7A-X2 11 11 11 13 ZP20B ZPT3-7A-X2 ZP 25 B ZPG25B-7A-X2 11 12 12 14 ZP25B ZP 32 B ZPG32B-7A-X2 14 15 15 18 ZP32B ZP 20 UT ZPG20UT-7A-X2 4 4 4 4 ZPT1-A6 ZP2-20UT ZP 16 J ZPG16J-7A-X2 8 8 8 9 ZPT2-7A-X2 ZP2-16J ZP B25 J ZPGB25J-7A-X2 14 15 15 18 ZP2-B25J ZPT3-7A-X2