In this case, a DIN rail which is approx. 30 mm longer than the manifold with the specified number of stations is attached. When DIN rail is unnecessary (DIN rail mounting brackets only are attached.) Indicate the option symbol, -D0, for the manifold part number.
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
For DC : SY100 30 4A For 100 VAC : SY100 30 1A Pin Groove Cover For 200 VAC : SY100 30 2A For other voltages of AC : SY100 30 3A Pin Groove Cover DC polarity indication Lever SY100 30 A Without lead wire : with connector and 2 pcs. of sockets only -+ Socket Lead wire Connector Lead wire length How to Order Indicate part numbers of the valve without connector and the required connector assembly
4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53 70.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 44.3 5.4 15.4 55 2.3 30.3 36.5 17.5 6 AR30-A 1/4, 3/8 1/8 53 83.5 27 28.5 M45 x 1.5 28.5 37.5 65 37.5 66 41 36 46 6.5 24 65 2.3 32.5 45.5 22.5 7 AR40-A 1/4, 3/8, 1/2 1/8 70 100 33.5
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 6 10 16 5, 10, 15, 20, 25, 30
5, 10, 15, 20, 25, 30, 35, 40, 45, 50 M5 x 0.8 M5 x 0.8 Double acting Single rod 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Suction flow rate L/min (ANR) Bore size (mm) 12/16/20/25 Size 5 12/16/20/25 Item Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 12, 16:
Switch Spacer Part No. 30 50 Size Switch spacer part no. BMY3-016 The above part number includes one switch spacer.
In this case, a DIN rail which is approx. 30 mm longer than the manifold with the specified number of stations is attached. When DIN rail is unnecessary (DIN rail mounting brackets only are attached.) Indicate the option symbol, -D0, for the manifold part number.
42.5 Bracket A (Option unit part no.: ZS-38-A1) 25 20 20 45 30 2 30 34.6 19 5.2 14.7 9.6 5.2 Bracket configuration allows mounting in four orientations.
Construction VHS20/30 VHS40/40-06/50 y i u w w t t r q IN OUT OUT IN q e o EXH. EXH. VM Component Parts No.
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+
(Assuming approximately 30% dispersion.) There may be the case it will vary substantially depending on an ambient environment.
Magnet: D (Built-in), Mounting: G (Rear Flange), Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector
Magnet: D (Built-in), Rod Type: Standard, Mounting: G (Rear Flange), Bore Size: 80mm, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in), Mounting: B (Basic), Size: 40 (Equiv. Ø40 Piston Area), Port Thread Type: M thread: ø25, Rc: 32 to 63, Stroke: 40mm, Rod End: M (Male Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: L (Shipped Together)
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,