D-859W D-B53, D-A53 0-A64. D-864 surgeabsolber D.A54, D-854, D-A44(C), D-A34(C) D-467 Feed switch D-A33(C) Solid State Type Internal Circuit D-F59, D-G59, D-G39(C) D-FsPW D-GsPW o Lalch typ d agnos s oinput Biue o D-FsP, D-GsP D.FsBAL, D.GsBAL, D-K59W, D-J59W D-F5NTL, D-GsNTL @ D-J59, D-K59, D-K39(C) ffit*' iffil.
W 2 J D C 21 B Nil Built-in magnet No Number of auto switches D With auto switch (Built-in magnet) Nil S n 2 pcs. 1 pc. n pcs.
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 743 Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting ASDF-D Series RoHS Model Applicable tubing O.D.
Applicable bore size (mm) D B1 C d H1 Part no.
D-M9K, D-Y7K, D-F7K Application For relay and PLC Applicable amplifier unit D-RNK, D-RPK Indicator lamp Red lights ON at sensitive position.
FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R VQ7-6-FPG-DValve replacement parts FHG FJG FIG FHG FJG FIG Description Material VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-D-R VQ7-6-DNo.
Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0
0 t r i w y e q o Replacement Parts (For valve) Description VQ7-8-FG-SVQ7-8-FG-DVQ7-8-FPG-DVQ7-8-FG-S-R VQ7-8-FG-D-R VQ7-8--D-R VQ7-8--DNumber q w e r t y u i o !
Output type Load voltage Lights when ON 2 color indicator Relay, PLC D-F9N D-F9NV NPN type 8mA or less 0.4V or less 28VDC or less 10A or less at 24VDC D-F9NW D-F9NWV D-F9P D-F9PV 12mA or less 24VDC (10 to 28VDC) 50mA or less Lights when ON 2 color indicator 10mA or less PNP type 1.5V or less D-F9PW D-F9PWV Lights when ON 4.5V or less D-F9B D-F9BV 1mA or less at 24VDC 24VDC (10 to 28VDC) 24VDC
D Constant Setting range : 0.0 to 99.9sec Min. increment : 0.1sec Indicated content : D constant(Ex. : 0.0sec) Function : Sets differential time used for PID control. D C o n s t a n t M O D E < 0 . 0 s e c When 0 is set, this function becomes invalid. 8-8 Operation 7.
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-T AS-D AS-T ASP ASN AQ ASV AK VCHC ASS ASR ASQ 591
MK(2) b) Type B mounting (When using the cylinder tube threads) RS Q G RS H A RZQ MI W S CEP1 CE1 CE2 ML2B E t E t C J G5-S Compatible Mounting Bolt Dimensions CV Model Type A mounting Type B mounting E (mm) D: Bolt length (mm) C (mm) Mounting bolt size Mounting bolt size MVGQ MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D 8 to 11 M3 x
l i O l e d o M s t e l t u o l i o f o r e b m u N k r a m e R 4 A V 4 s d n e h t o B 6 A V 6 s d n e h t o B Dimensions/Auto feed tank 0 1 A V 0 1 s d n e h t o B 6 1 A V 6 1 s d n e h t o B 4 B V 4 e d i s e n O 6 B V 6 e d i s e n O 8 B V 8 e d i s e n O s n o i t a c i f i c e p S h c t i w S t a o l F n o i t p i r c s e D 2 ~ 1 0 1 4 S I y t i c a p a C W 5 1 : C D , A V 5 1 : C A
MK(2) b) Type B mounting (When using the cylinder tube threads) RS Q G RS H A RZQ MI W S CEP1 CE1 CE2 ML2B E t E t C J G5-S Compatible Mounting Bolt Dimensions CV Model Type A mounting Type B mounting E (mm) D: Bolt length (mm) C (mm) Mounting bolt size Mounting bolt size MVGQ MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D 8 to 11 M3 x
Output type Load voltage Lights when ON 2 color indicator Relay, PLC D-F9N D-F9NV NPN type 8mA or less 0.4V or less 28VDC or less 10A or less at 24VDC D-F9NW D-F9NWV D-F9P D-F9PV 12mA or less 24VDC (10 to 28VDC) 50mA or less Lights when ON 2 color indicator 10mA or less PNP type 1.5V or less D-F9PW D-F9PWV Lights when ON 4.5V or less D-F9B D-F9BV 1mA or less at 24VDC 24VDC (10 to 28VDC) 24VDC
Fluids VCC Series Union Nut Socket 1209 1008 1075 VCC-G-D-1 (Applicable fitting VCK ) VCC-G-D-1 2 13 Width across flats: 19 25.5 14 60 VCC-G-D-2 (Applicable fitting VCK ) 0806 0604 9 Width across flats: 17 20.5 14 50 For extending the socket VCC-G-D-1 VCC-G-D-1 VNA 113 VNB SGC SGH VCC-G-D-1 VNC VNH VCC-G-D-2 VND 97 VCC VCC TQ 655 VCC Series Disassembly/Assembly/ Maintenance Procedure Cleaning