Stations: 4 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: N [NPN (-)]
Stations: 1 Station, Port Size: C6 (ø6 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: N [NPN (-)], Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)
Stations: 3 Stations, Port Size: L4 (Elbow Top Ported ø4 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 1 (M12, 2 Inputs), Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)
Stations: 4 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 1 (Input Block 1 pc.), Input Block: 2 (M12, 4 Inputs)
Stations: 1 Station, Port Size: N7 (1/4" One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: N [NPN (-)]
Stations: 4 Stations, Port Size: B3 (Elbow Bottom Porting w/ø3.2 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 4 (Input Block 4 pcs.), Input Block: 1 (M12, 2 Inputs)
Stations: 4 Stations, Port Size: N1 (1/8" One-touch Fitting), SI Unit: TCN (AS-i 8 in/out - 31 Slave Modes - 1 Power Supply Systems, -COM), Number of Input Blocks: 0 (w/o Input Block)
Stations: 4 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)]
Stations: 2 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 0 (w/o Input Block)
Stations: 3 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 0 (w/o Input Block)
Stations: 4 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 0 (w/o Input Block)
Stations: 3 Stations, Port Size: C4 (ø4 One-touch Fitting), SI Unit: TAN (AS-i 8 in/out - 31 Slave Modes - 2 Power Supply Systems, -COM), Number of Input Blocks: 0 (w/o Input Block)
Auto switches are integrated as standard.Magnetically coupled rodless cylinder, Low profile guide type, Overall length reduced by 31%, Bore sizes *: 10, 15, 25, Auto switches available, BASE CYLINDER, ACTUATOR, CY1F MAGNETICALLY COUPLED CYL, IE, 25MM CY1F DBL-ACT AUTO-SW, 6.90597 lb
Auto switches are integrated as standard.Magnetically coupled rodless cylinder, Low profile guide type, Overall length reduced by 31%, Bore sizes *: 10, 15, 25, Auto switches available, CYLINDER, ACTUATOR, CY1F MAGNETICALLY COUPLED CYL, IE, 25MM CY1F DBL-ACT AUTO-SW, 7.05479 lb
Click Cancel to close the dialog box. 31 - 5.2 JOG Operation This function turns the motor at the set JOG speed. The rotational direction and the speed setting can be verified without connecting a PC or PLC etc. WARNING Performing JOG operation while the motor is running is dangerous. Be sure to check the user's manual before executing. Pay particular attention to the following.
Failing to comply may cause an injury or accident, or damage to the actuator and the user's system. 31 - 4.2.
LEC-OM04601 2012 4 URL http//www.smcworld.com 2012 SMC Corporation All Rights Reserved 31 -
Therefore the INF output may be activated when the pushing force differs from the set "Thrust Setting Value". 31 - INFP signal The output turns ON when the current Card Motor table position is within the positioning repeatability range (LAT3 is 0.09 mm, LAT3F is 0.005 mm) of the target position. The output conditions for each operation mode are similar to those for the INP signal.
(Refer to page 31) Then press button again to change the pressure while the display is flashing. : ON/OFF point of the supply pilot valve and the set point of the input prohibited range of the supply pilot valve may be corrected by the auto-preset function. -30NO.ZK2-OM00501-B Auto-preset When auto-preset is selected in function selection mode, the set value can be calculated and memorized
(Refer to page 31) Then press button again to change the pressure while the display is flashing. : ON/OFF point of the pilot valve for supply and the set point of the input prohibited range of the pilot valve for supply may be corrected by the auto-preset function. -30NO.TQ1050188-OM002 Auto-preset When auto-preset is selected in function selection mode, the set value can be calculated and