Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum
Note 2) C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed. 587 AS-FS Series Elbow Universal Brass 1 Electroless nickel plated How to Order Applicable tubing O.D.
F S E C IN D E C To obtain the operation manual about this product and control unit, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly. S D IN IN Press the button continuously to keep decreasing the set value. S Screw is prepared by customer. Name Description Symbol Direct mounting Direct mounting A Display See below.
L-27S SUS316 U-8SU-9SU-10S SUS304 SUS304 J-4S SUS316 AL-25S NBR O AL-22S FKM CY-27S SUS304/SWCH SUS304 SUS304 SS400 BH-73S BH-77S 5/8 FGX-OM-L011 2 2. 0.7MPa 80 27L,43L,52L 19.5kg,23kg,30kg 0.1MPa 3 M12 23 4 1 V 2 6 [] 23 6/8 FGX-OM-L011 5 1 INLETOUTLET O (1)(2) (2) AL-25S(:NBR) AL-22S(:FKM) (1) 2 3 23 7/8 FGX-OM-L011 4 O O 1 2 (1) (2) 5 (a)(b) V [(c)] [(c)] O 1 V V
Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)% (2) And following instructions must be executed.
Select cable type and len gth surely. e xamp le S2S2Standard c able 2m+ d river LEC SS2 S2 Standard c able2m Nil Witho ut cab le and driver 100 to 120 LECSB1S B1 200 to 230 LECSB2S B2 100 to 120 LECSC1-S C1 *5 Mo tor cable and enc o der cable are included as a ccessories.
Refer to p.0-39 to 0-46 for Safety Instructions and common precautions. CM2 C85 Construction (Disassembly is not possible.) CG1 Piping Caution Panel mounting MB q Use a dedicated hose nipple. On the panel mounting style, use the CJ-5H-4 or CJ-5H-6, a dedicated hose nipple (with a fixed restriction) that is provided.
Series 10/11 -CQSX Series10/11 -CQ2X How to Order How to Order Clean room series 10 11 Clean room series 10 11 Relieving type Vacuum type Relieving type Vacuum type C(D)QSX B 20 10 30 A90 C(D)Q2XB 40 10 30 A73 D D With auto switch With auto switch (with built-in magnet) (with built-in magnet) Microspeed cylinder Microspeed cylinder Mounting Cylinder stroke (mm) Bore size Number of auto
GEnlarge cover and mount cover onto mounting area. 3 1 C 2 4 5 Cover mounting area Cover How to Order N 04 DM 6 Number of connecting tube 6 12 6 12 Accessories(optional) 1 cover(One side) 2 covers(Both sides) C1 C2 Type Tube material P 12 Multi-connector Plug side Socket side N Nylon Soft nylon Polyurethane NU Tube O.D. 4mm 6mm 04 06 70 Series DM Multi-connector Dimensions (mm) DM6 Panel
N300 P NGJP seies Air Cylinder Pin Cylinder Compact Design Minimizes Mounting Space Five Mounting Styles Avaihbb Bore sizes: o6mm, a10mm, g15mm Auto Switch Capable Double Acting sil'tr 5-tt3Y*%S/DoubleA o INDEX A u t o S w i t c h . . . . . . . . 5 Contact Protection Box How to Mount How to Order 1 Specifications Mounting BracketyPart No., Options, Cylinder Theoretical Force and Weight
dm3/s-bar) b Cv C(dm3/s-bar) b Cv VHS20 1/8 1/8 4.0 0.41 1.1 3.7 0.42 1.1 1/4 5.8 0.31 1.4 3.8 0.42 1.1 6 VHS30 1/4 1/4 8.8 0.44 2.4 8.0 0.46 2.3 3/8 14.1 0.28 3.5 7.8 0.46 2.2 1/4 9.5 0.49 2.8 13.3 0.47 3.6 VHS40 3/8 17.2 0.47 4.8 13.6 0.47 3.7 3/8 1/2 26.7 0.29 6.3 13.4 0.43 3.7 -6- 4.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be 3% or less of the rated voltage. 6.
Delivery Pressure: 06 [2 to 60 psig (0.014 to 0.4 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: M [10 μin. (0.25 μm)], Ports: 4PW [4 Ports (1-In; 2-Out; 3-Gauge Port In; 4-Gauge Port Out)], Connections, Inlet: MV4 (1/4 Inch Face Seal, Male), Connections, Outlet: FV4 (1/4 Inch Face Seal
Delivery Pressure: 06 [2 to 60 psig (0.014 to 0.4 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: M [10 μin. (0.25 μm)], Ports: 4PW [4 Ports (1-In; 2-Out; 3-Gauge Port In; 4-Gauge Port Out)], Connections, Inlet: MV4 (1/4 Inch Face Seal, Male), Connections, Outlet: MV4 (1/4 Inch Face Seal
Delivery Pressure: 06 [2 to 60 psig (0.014 to 0.4 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: M [10 μin. (0.25 μm)], Ports: 4PW [4 Ports (1-In; 2-Out; 3-Gauge Port In; 4-Gauge Port Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face