Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
AS120M-M5 M5 x 0.8 9 9 8 10 28.2 24.8 10.3 29.8 33.2 AS120M-U10/32 10-32 UNF AS220M-01 12 R 1/8 Rc 1/8 14.3 14.6 18 31.4 27.4 14.1 32.4 36.4 AS220M-N01 NPT 1/8 12.7 AS220M-02 17 R 1/4 Rc 1/4 18 19.5 27.2 35.9 29.9 18 34.9 39.9 AS220M-N02 NPT 1/4 17.5 Dimensions of R and NPT threads after installation. 15-9-63
Solenoid valve model VO307-1 0.3 to 0.7 MPa Valve unit Small flow Large flow Solenoid valve type Stop valve Skip valve Valve type Nominal size (mm) 63, 100 100, 160 External pilot pressure N.O No mark 100, 200, 110, 220, 240 No mark N.O AC (50/60 Hz) Coil rated voltage (V) 24, 12 Valve opens when solenoid valve conducts electricity.
Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.
(Put packing B w on the surface contacting to the end plate.) 4 stations (12 stations) 5 stations (13 stations) 3. For a style with a D-sub connector, open the cover !4 and insert the pin of lead wire assembly !0 as shown in the right figure.
Fault No.12 Fault Probable cause Recommended error handling Recommended action Valves do not work but valve LEDs are operating Mismatch polarity between solenoid valve and SI unit output Check if the solenoid valve common specification matches the output polarity of the SI unit.
LED in pairing mode (wireless master) -104No.EX-OMV0017 (12) Click the Refresh button to update the information in the setting tab window.
EX600-ZT1 (6) Assembled type connector PCA-1446553: For EtherCAT communication, M12 (4 pin) Plug, D code PCA-1578078: For power supply, 7/8 inch, Plug, Cable O.D. 12 to 14 mm PCA-1578081: For power supply, 7/8 inch, Socket, Cable O.D. 12 to 14 mm (7) Power supply cable PCA-1558810: Cable with 7/8 inch connector, Socket, Straight 2 m PCA-1558823: Cable with 7/8 inch connector, Socket, Straight
Pressure Characteristics 3 5%F.S. (0 to 0.75 MPa, 0.35 MPa standard) Power supply voltage 12 to 24VDC 10% Ripple (p-p) 10% or less Electrical Current consumption 55 mA or less Protection Polarity protection Display accuracy 3%F.S. Analogue output accuracy 3%F.S.
Pressure characteristics 3 5%F.S. (0 to 0.8 MPa, 0.6 MPa standard) Power supply voltage 12 to 24 VDC 10% Ripple (p-p) 10% or less Electrical Current consumption 55 mA or less Protection Polarity protection Display accuracy 3%F.S. Analogue output accuracy 3%F.S.
V300 24 V600 Max.30 V80 mA 1 V 2815 V 1 k 29420 mA 12 V300 24 V600 -40No.PF-OMO0007CN PF2A7--28--X560 PF2A7--68--X560 PF2A7--29--X560 PF2A7--69--X560 (15 V) (420 mA) 12 V 300 24 V 600 1 k 5F.S. 1 s A B 1 V 5 V 4 mA 20 mA 1 NL/min 10 NL/min PF2A710 3.5 CFM10 -2 35.0 CFM10 -2 5 NL/min 50 NL/min PF2A750 18 CFM10 -2 176 CFM10 -2 10 NL/min 100 NL/min PF2A711 3.5 CFM10 -1 35.5 CFM10
No.PF-OMG0008-F PRODUCT NAME Digital Flow Switch (Remote type monitor unit) MODEL / Series / Product Number PF2A3## PF2W3## PF2D3## Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 14 Installation 14 Wiring 16 Outline of setting 18 List of outputs 19 Initialize mode 20 Default settings
4 4 4 M12 IN OUT ( ( ( (2 2 2 2 ) ) ) ) ( ( ( ( ) ) ) ) UP UP UP UP SET SET SET SET DOWN DOWN DOWN DOWN (2 ) () OUT1OUT2 ON : UP ON/OFF SET DOWN ON/OFF 13 No.LFE*-OMY0008 F F.S.( 15V F.S.=5[V]1[V]4[V](1F.S.4[V]10.04[V]) a 1-5V 1-5V 4-20mA (HYS) ON OFF 63% ka () sa 10 L/min 10 L ON OFF ON () OFF () 2 5 5 10 L/min 10550L 14 No.LFE*-OMY0008 sa ON-OFF () 1 L/min 10 11 12
Install a dryer (IDF series), air filter (AF/AFF series), and/or mist separator (AFM/AM series) to the upstream of the product to obtain clean compressed air. 12. Air connections should only be made with the pressure supply turned off. Flush the system before piping to prevent foreign matter from entering inside the product. 13.
Install a dryer (IDF series), air filter (AF/AFF series), and/or mist separator (AFM/AM series) to the upstream of the product to obtain clean compressed air. 12. Air connections should only be made with the pressure supply turned off. Flush the system before piping to prevent foreign matter from entering inside the product. 13.
Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 12 L/min. Since this is equivalent to 68% of the discharge rate for fresh water, 12 L/min 0.68 =17.6 L/min, indicating that a discharge rate of 17.6 L/min is required for fresh water. 3.
Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 12 L/min. Since this is equivalent to 68% of the discharge rate for fresh water, 12 L/min 0.68 =17.6 L/min, indicating that a discharge rate of 17.6 L/min is required for fresh water. 3.
Parts replacement procedure 12 1 XL*-OMI0009-E Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.