Double energy saving function series (IDF125FS) Standard model (IDF125F) Note) [Trial calculation conditions] Days of operation per year = 240 days (60 days each in spring, summer, autumn and winter), Operation hours per day = 12 hours, Operating conditions = Refer to the conditions shown below.

Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.

CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 6 10 16 5, 10, 15, 20, 25, 30 11-/22-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 11-/22-CDU25 25 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item Size Suction flow rate L/min (ANR) 6 10 16/20/25 6 10/16 20/25 6 10 12

Option Specifications 24, 48, 110, 220 VAC (50/60 Hz) 6, 12, 48 VDC Locking type (Tool required) With light/surge voltage suppressor Note) Coil rated voltage Plug-in type Manual override Option Note) Plug-in, K plug connector type is standard with light/surge voltage suppressor.

IN side, OUT side 4 10 20 30 50 75 75 Weight (g) 22 22 30 30 39 39 Model Tubing size ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 7 7 12 12 16 16 Unrestricted 360 piping tube mounting on the IN side 6 6 8 8 10 Metric size Easily replaced filter element Easy installation and removal with One-touch fittings ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 22 22 30 40 62 20 20

Digital Pressure Switch Series ZSE4BjlSE4DB Internal Circuit and Wiring -25 NPN open collector -26 analog output type -65 PNP open collector -: -'Red : I R&d Power supply +Terminal ---'Red , + +12 24VDC 12-24VDC I : , 1 _ 12--24VDC LED [Red) LEO (Red) , , ___ ___ _ I __ __ ___ ___ I Black Power supply GND terminal I _ __ _ I Slack Power supply GND terminal ___' Black Power supply GND terminal

Model Nozzle diameter (mm) Maximum suction flow rate (/min(ANR)) Max. vacuum pressure Air consumption (/min(ANR)) Weight (g) Type Model (kPa) High vacuum type Large flow type ZU05S 0.5 7 6.5 85 9.5 ZU07S 0.7 12 7.0 85 19.0 ZU05L 0.5 12 6.5 48 9.5 ZU07L 0.7 21 7.0 48 19.0 Supply pressure: 0.45 MPa Construction Dimensions ZU05S/ZU05L 59 EXH Diffuser Body 12.8 VAC SUP ZU07S/ZU07L 66 One-touch

10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 5 10 15 20 Suction flow rate [L/min(ANR)] Suction flow rate [L/min(ANR)] Supply pressure [MPa] Supply pressure [MPa] Dimensions 2 x Applicable tubing O.D. 6 10.4 9.7 L1 L2 13.3 12 13.3 2 x Connection thread Rc1/8 13.3 12 L1 One-touch Connection Screw-in Connection Model L1 L2 ZU05mA 52 25.4 ZU07mA 59 32.4 Model L1 ZU05mA01 67.2 ZU07mA01 74.2 2 These safety

Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5

V Solid state switch Relay, PLC 24 V Grommet Yes 12 V 5 V, 12 V 12 V 100 V or less 100 V IC circuit no Yes Relay, PLC 24 V 2-wire Reed switch Grommet 161

Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less