SMC Corporation of America
Elite Part Number Search
Search Results "AL20-02B-C-A"

Application 8 7 6 5 4 3 2 Communication connector 1 9 Ground terminal Used for grounding EX500 Part Names Station number switch protective cover Set address and bus terminator by using the switches under this cover. ( Note2 ) Display Communication port D ( COM D ) Communication port C ( COM C ) Communication port B ( COM B ) Communication port A ( COM A ) Power supply connector Display the

Install a micro mist separator or Super Mist Separator on the outlet side of this equipment. Grease is applied inside of the Regulator used in the V type unit. When air with high purity is required, please either mount the Super Mist Separator on the outlet side or use a made-to-order product, which is provided with a Micro Mist Separator (Series AWD) instead of a Regulator. c.

AR20K-B to AR60K-B A-A w A 2 OUT 1 I N C SM A w w Pressure in diaphragm chamber Inlet pressure (IN) Pressure in diaphragm chamber Inlet pressure (IN) r r IN OUT IN (Inlet pressure) OUT (Outlet pressure) q q e e Figure 1 Normal Figure 2 Backflow When the inlet pressure is higher than the regulating pressure, the check valve w closes and operates as a normal regulator (Figure 1).

(P.124) Wetted Parts Material S H Wetted Parts Body Surface finish Diaphragm Seat Hastelloy C-22 Electropolish 316L SS secondary remelt Electropolish + Passivation Elgiloy is a registered trademark of Elgiloy Specialty Metals. Hastelloy is a registered trademark of Haynes International. Vespel is a registered trademark of DuPont.

14, 2 (PA, B) 4, 25, 3 (A, BEA, EB) Model 4, 2 (A/B) 1, 5, 3 (P/EA/EB) C[dm3/(sbar)] C[dm3/(sbar)] Cv Cv b b C6 SS5V1-16 C8 0.89 0.22 0.23 0.22 0.21 0.98 C8 SS5V2-16 C10 2.3 0.50 0.56 0.28 0.18 2.7 Note) Value is for manifold base with 5 stations and individually operated 2 position type.

C Rubber Bumper M Male Rod CM Rubber Bumper & Male Rod Feed Switch B Basic Model A Threaded Mounting Holes.

Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a e B part f d z f1 x.Calculate the inertial moment of the attachment. Assuming the attachment material is aluminium alloy (relative density=2.7), r1= 16.4 (mm).

Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com e B part f d z f1 x.Calculate the inertial moment of the attachment.

Operating model: MHY2-16D Opening time: 0.15s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d Material of attachment: Aluminum alloy (Specific gravity = 2.7) r1 = 37 (mm) z r1 Calculate the moment of inertia of attachment.

B 19.5 25 29.5 C 6.5 7 14.5 A 8 8 8 8 10 10 Model MGQ32 MGQ40 MGQ50 MGQ63 MGQ80 MGQ100 Detailed figure of a section Detailed figure of b section a a a b MGQ32 to 50 MGQ63 to 100 8-20-10 11 Compact Guide Cylinder Series MGQ Proper Auto Switch Mounting Position (Detection at stroke end) Minimum Stroke for Auto Switch D-Z7/Z80 D-Y5/Y6/Y7(V) D-Y7W(V) 1 pc. 2 pcs. 5 10 5 5 10 15 Auto switch D-Z7

C 0.2 B 0.2 0.1 A 0.2 0.05 100 1000 D (mm) MGPWM MGPWL/A Hexagon socket head cap screw 126 146 176 192 240 266 Maximum speed (mm/s) Bore size (mm) A (mm) B (mm) C (mm) 20 25 32 40 50 63 24 30 34 40 46 58 108 128 156 172 220 248 12 14 18 18 22 22 12 15 18 18 22 22 M5 x 0.8 M6 x 1.0 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 Other Caution Do not use this cylinder as a stopper. 518

C Rubber Bumper M Male Rod CM Rubber Bumper & Male Rod Feed Switch B Basic Model A Threaded Mounting Holes.

Orange ZS-28-C-2 1.2 to 1.6 7. Pressure setting There are two methods for pressure set-up: manual and auto preset, either one of which can be selected. The auto preset is provided for an automatic optimum set-up by using a sample for a case in which switch output is used to check adsorption. The operation mode currently selected is displayed.

Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24-M3 x 0.5 B phase J A B C D A COM COM COM B 12 VDC GND F.G.

Use a tightening torque of 0.05 to 0.1 Nm. As a rough guide, tighten the screw an additional 90 after feeling a tight resistance. As a rule, it should be turned about 90 beyond the point at which tightening can be felt. 0.5 0.2 0.3 MHL2-20D 0.5 0.2 0.2 MHC MHL2-25D 0.2 0.1 0.2 MHL2-32D 0.4 0.4 0.7 MHT MHL2-40D 0.2 0.4 0.7 MHY MHW MRHQ Misc.

MS (4) Barb cassette B T A VMG C + Driver 1. Turn the clamp bolt (6) to the left with a screwdriver, loosen until the stopper (2) touches the case (3), and barb cassette (4) will be pulled out in the direction A. Then clamp portion B, consisting of barb (5) and case (3), will be freed. Next, insert or remove the tube. 2.

Symbol 0 A square plug set is normally used for the drain unit.

When the pressure gauge is attached, a 0.2 MPa pressure gauge will be fitted. Note 7) Float type auto drain: The combination between C and D is not available. Note 8) Without a valve function Note 9) Metal bowl: The combination of 2 and 8 cannot be selected. Note 1) Drain guide is NPT1/8 (applicable to the AWM20, AWD20) and NPT1/4 (applicable to the AWM30 to AWM40, AWD30 to AWD40).