SMC Corporation of America
Elite Part Number Search
Search Results "RS2H50-30DM-DC-M9BASDPC"

, 100, 110, 200, 220V AC (50/60Hz) Coil rated voltage 10% of rated voltage Allowable voltage Class B or equivalent Coil insulation (3) (4) 24V DC 1W DC (42mA), 1.5W DC (63mA) , 0.5W DC (21mA) (3) (4) 12V DC 1W DC (83mA), 1.5W DC (125mA) , 0.5W DC (42mA) Solenoid Power consumption 100V AC Inrush 0.5VA (5mA), Holding 0.5VA (5mA) (Current value) 110V AC Inrush 0.55VA (5mA), Holding 0.55VA (5mA

() IN DC (+) DC () IN DC (+) Brown Black Blue Brown Blue Pressure sensor (Current output) Pressure sensor (Voltage output) DIN Rail ISA-5Part no.

Connect DC when PNP is applied, and DC+ when NPN is applied.

Run mode There are 3 different run modes (Sensing DC mode/Pulse DC mode/DC mode) for the IZS31, which can be selected based on the application and operating condition. (1) Sensing DC mode The discharge time is reduced by detecting the workpieces charge condition with a feedback sensor which feeds the data back to the ionizer and causes ions with the polarity best suited for static neutralization

(42 mA), 1.5 W DC (63 mA) (3), 0.5 W DC (21 mA) (4) 24 VDC 1 W DC (83 mA), 1.5 W DC (125 mA) (3), 0.5 W DC (42 mA) (4) 12 VDC 100 VAC Inrush 0.75 VA (7.5 mA), Holding 0.75 VA (7.5 mA) Power consumption (Current) Rubber seal 110 VAC Inrush 0.83 VA (7.5 mA), Holding 0.83 VA (7.5 mA) 200 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 3 position closed center 220 VAC Inrush 1.1 VA (5 mA), Holding

0 to 20 mA DC Vs : Power supply 24 VDC Vin : Input signal 0 to 5 VDC 0 to 10 VDC When 80 mA DC or more is applied, detecting device for over current starts activating and then emits an error signal.

) DIN terminal without connector (DC specification) None Use standard (DC) specification for continuous duty.

DC (+) q 6 Red CH3_OUT1 5 Gray CH2_OUT1 4 White N.C. 3 Black CH1_OUT1 2 Blue DC() 1 Brown DC(+) DC () w CH1_OUT1 e N.C. r CH2_OUT1 t 2000 CH3_OUT1 y CH4_OUT1 u N.C. i Internal circuits and wiring examples PF2A200 PF2A201 DC (+) DC (+) 4 3 2 1 4 3 2 1 (Brown) (Brown) Sensor Sensor Sensor + Load Load Load Load + NC NC 24 VDC CH1_OUT1 CH1_OUT1 24 VDC (Black) (Black) 4 3 2 1 4 3 2 1 Load Load

Oil AC DC AC DC (mm2) MPa AC DC 0.7 0.6 0.7 0.6 1/4 VXZ2232-02 10 1.9 34 0.7 0.6 0.7 0.6 0.7 0.6 3/8 VXZ2232-03 1.5 10 2.4 43 0.7 0.6 0.7 0.6 0.7 0.6 1/2 VXZ2242-04 15 5.3 95 0.7 0.6 Courtesy of Steven Engineering, Inc. !

Load U Blue DC () Blue DC () Max. applied voltage: 28 V, Max. load current: 80 mA, Internal voltage drop: 1 V or less Max. load current: 80 mA, Internal voltage drop: 1.5 V or less PNP + Analog output type PF2M7mm-m-E/Fm-mmm NPN + Analog output type PF2M7mm-m-C/Dm-mmm Brown DC (+) Brown DC (+) Brown DC (+) Brown DC (+) Load Load U Black OUT1 Black OUT1 Load Load U 12 to 24 VDC + 12 to 24

(Maximum transmission distance: 4 m) * This function is not provided with the IO-Link compatible type. 1 unit 2 units 10 units Master Slaves (Max. 10 units) Slave sensors 1 unit 2 units n units (Max. 10 units) Master sensor DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () Blue Gray (Copy wire) Brown Blue Gray (Copy wire) Brown

2-wire type OUT ( ) Blue OUT () Brown DC 2-wire, Non-polar type Diagnostic output OUT Black DC () Blue DC (+) Brown DC 3-wire type OUT Black DC () Blue Orange DC (+) Brown DC 4-wire type Connector Specifications Connector model M83 pin M84 pin M124 pin 1 2 1 4 M83 pin Pin arrangement 1 2 3 4 4 3 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main

(+) DC(+) 2 6 + SMC FLOW SWITCH Blue DC() DC() 1 5 12 to 24 VDC 35.8 A 40 UNIT RESET -1 PNP (2 outputs) SET Load OUT2 8 4 3 x 7.2 (= 21.6) 8 x M3 Sensor input Load Black OUT1 7 3 6.4 Brown DC(+) DC(+) 2 6 + Blue DC() DC() 1 5 1 2 3 4 12 to 24 VDC 19.4 Terminal block numbers 5 6 7 8 4 3 2 1 View A 1 2 3 4 Panel fitting dimensions 5 6 7 8 43 or more Static Electricity Elimination Equipment

2-wire type OUT ( ) Blue OUT () Brown DC 2-wire, Non-polar type Diagnostic output OUT Black DC () Brown Blue DC (+) DC 3-wire type OUT Black DC () Brown Orange Blue DC (+) DC 4-wire type Connector Specifications Connector model M83 pin M84 pin M124 pin 1 2 1 4 M83 pin Pin arrangement 1 2 3 4 4 3 3 Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Impact resistance 300

AWD ITV Wiring diagram Current signal type Voltage signal type VBA Brown Brown VE Blue Blue Vs Vs White White VY Black Black A Vin G 24V DC 12 to 15V DC 4 to 20mA DC 0 to 20mA DC Vs: Power supply Vs: Power supply 24V DC 12 to 15V DC 0 to 5V DC 0 to 10V DC AL Vin: Input signal A : Input signal Preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24V DC 12 to 15V DC One of the

(RedGreenRed) Wiring 3 wire 2 wire NPN Output PNP Application IC circuit/Relay/PLC 24V DC Relay/PLC Power voltage 5/12/24V DC (4.5 to 28V DC) Current consumption 10mA 28V DC Load voltage 24V DC (10 to 28V DC) 40mA 80mA Load current 5 to 40mA 1.5V ( 0.8V at 10mA load current) 0.8V Internal voltage drop 4V 100A at 24V DC 0.8mA at 24V DC Current leakage Operating point: Red light emitting diode

(Maximum transmission distance: 4 m) 1 unit 2 units 10 units Master Slaves (Max. 10 units) Slave sensors 1 unit 2 units n units (Max. 10 units) Master sensor DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () Blue Gray (Copy wire) Brown Blue Gray (Copy wire) Brown Blue Gray (Copy wire) Brown Blue Gray (Copy wire) Brown 1) Wire as