(Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient and fluid temperature: -10 to 50C, SQ2000 BUILT IN FITTING >1/4, VALVE, SQ2000 BUILT IN FITTING >1/4, SeriesType of actuationSealModelFlow characteristic (1)Response time (ms) (2)Weight (g) 1 4/2 (P A/B)4/2 5/3 (A/B R1/R2)Standard(0.4 W)Quick
(Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient and fluid temperature: -10 to 50C, SQ2000 BUILT IN FITTING >1/4, VALVE, SQ2000 BUILT IN FITTING >1/4, SeriesType of actuationSealModelFlow characteristics (1)Response time (ms) (2)Weight (g) 1 4/2 (P A/B)4/2 5/3 (A/B R1/R2)Standard(0.4 W)Quick
/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, ELBOW NIPPLE, VALVE, SJ2000/SJ3000/SZ3000, 21, SZ NO SIZE RATING, .13200 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, ELBOW NIPPLE, VALVE, SJ2000/SJ3000/SZ3000, 21, SZ NO SIZE RATING, .13200 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, BUSHING ASSY *LQA, VALVE, SJ2000/SJ3000/SZ3000, 21, SZ NO SIZE RATING, .00066 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE 2POS/SGL, CASSETTE TYPE, 4/5 PORT SOLENOID VALVE, G92, 74 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, PLUG IN, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 3-PORT, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE 2POS/DBL, W/O CONNECTOR, 4/5 PORT SOLENOID VALVE, 0.03 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 4/5 PORT SOLENOID VALVE, 78 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 4/5 PORT SOLENOID VALVE, 78 lb
5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, PLUG IN *LQA, VALVE, SJ2000/SJ3000/SZ3000, UD, SZ BUILT IN FITTING 1/4), .20527 lb
5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140
Please contact us for the latest version.sales@ocaire.com, COOLANT VALVE, SOL, VALVE, VNA/B/C/D 2-WAY MEDIA VALVE, 1A, VNA/B/C/D, 4.12176 lb, ModelOperating fluid pressureFluid (Main piping)OperationOperating fluid temperaturePilot airProof pressureAmbient temperatureMax. operating frequencyMounting positionPort sizeOrifice diameter (mm)Flow characteristics Av x 10-6m2Pilot port sizeMass