Through-hole/CQ2YB, CDQ2YB Both ends tapped/CQ2YA, CDQ2YA Both ends tapped (mm) Bore size (mm) 63 O1 R O1 thread R R M10 x 1.5 18 80 M12 x 1.75 22 100 M12 x 1.75 22 H thread effective depth C 4-N through 8-O counter bore U Q F 2-P (Port size) (Rc, NPT, G) I 22 M E D Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J B + Stroke A + Stroke L Rod end male thread H1 Rod end
PT) 14 8 21.5 13.1 16.2 17 R(PT) 10 24 20.4 25.6 17 19 22 25.5 12 30.4 35.4 Reference dimensions after R(PT) installation.
Standard stroke (mm) Model 100 75 50 40 30 20 10 CXSM6-R CXSL6-R CXSM10-R CXSL10-R CXSM15-R CXSL15-R CXSM20-R CXSL20-R CXSM25-R CXSL25-R CXSM32-R CXSL32-R 0.105 0.105 0.18 0.18 0.3 0.32 0.465 0.485 0.72 0.73 1.33 1.35 0.12 0.12 0.2 0.2 0.33 0.35 0.5 0.52 0.76 0.77 1.43 1.45 0.135 0.135 0.225 0.225 0.355 0.375 0.54 0.56 0.8 0.81 1.53 1.55 0.15 0.15 0.25 0.25 0.38 0.4 0.58 0.60 0.84 0.85 1.62
/See 2.1 Specifications on p.9 /See 3.1 Specifications on p.12 Use within specification range. 3) Load/resistance more than /See 2.1 Specifications on p.9 specified range is being applied /See 3.1 Specifications on p.12 to the actuator.
3 y r t !1 A A Enlarged view of A Component Parts Description No.
Dimensions are the same as the standard model. 2.35J 11.8 40 Construction: Refer to p.1.4-9 Dimensions: Refer to p.1.4-10 to 1.4-18 Construction: Refer to p.1.4-9 Dimensions: Refer to p.1.4-10 to 1.4-18 Refer to p.1.4-4 for other specifications.
Indicator light Output 1 and 2: Orange Power supply Used as switch output device 12 to 24 VDC, including ripple (p-p) 10% voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 50 mA max.
222 CC-Link p. 223 DeviceNet p. 224 PROFIBUS DP p. 225 Communication Cable p. 226 Field-wireable Communication Connector p. 228 Terminating Resistor p. 228 Fieldbus Related Accessories M8/M12 Connector PCA/EX9/EX500 Series Power Supply Cable/Connector EX600 Series p. 229 EX500 Series p. 231 EX260 Series p. 233 EX250 Series p. 235 Accessory Between the Sensor/Switch and the Input
JIS B2401-1A-P85 NBR I.D. 84.6 x 5.7 O-ring r JIS B2401-4D-P85 FPM JIS B2401-1A-P11 NBR u !
P F H J L N P R Option Code Specification Standard (Cv: 0.06) High flow (Cv: 0.12) No code HF O-ring material 1) Not available for material code B.
+ Clamp stroke X Z C 0.2 2 x 4-H counterbore Q + 2 x Clamp stroke + 0.15 + 0.05 2-3.3 depth 3 K A P Both ends tapped style: MKA A thread (mm) A B Model MKA MKA50 MKA63 32 40 10 M6 x 1.0 14 M8 x 1.25 18 M10 x 1.5 R + Clamp stroke (Basic) (mm) Q A G I J S T B H K L O U C P V D E R X F Yh9 Z Model 0.1 0.2 MKB32 1 8 0 0.15 0.15 31.5 9 depth 7 M10 x 1.5 93.5 71.5 45 5.5 12 37 7.5 60 14 16 34 4.5
ZB-OM00201-B Revision history A P.19 Recommended tube fittings P.21 Piping to the Manifold Base B P.21 Change of description about tightening of fitting.
Through-hole: CQ2YB/CDQ2YB Both ends tapped style: CQ2YA/CDQ2YA CDQ2YA RE A B Both Ends Tapped (mm) Bore size (mm) O1 R O1 thread REC R R 32 M6 x 1.0 10 40 M6 x 1.0 10 CX 50 M8 x 1.25 14 CY MQQ M RHC H thread effective depth C U 4-N through 8-O counterbore Q F 2-P (Port size) (Rc, NPT, G) MK(2) I RS Q G RS H A 22 D M E Z 11 Lead wire min. bending radius 10 RZQ Auto switch D-A7, A8 MI W S
Through-hole: CQ2YB/CDQ2YB Both ends tapped style: CQ2YA/CDQ2YA CDQ2YA RE A B Both Ends Tapped (mm) Bore size (mm) O1 R O1 thread REC R R 32 M6 x 1.0 10 40 M6 x 1.0 10 CX 50 M8 x 1.25 14 CY MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RHC H thread effective
Taper ring Steel ball P f R R High locking efficiency Greater locking efficiency as well as stable locking and unlocking operation has been achieved by arranging a large number of steel ball bearings in circular rows.
* Light/Surge voltage suppressor : $$ $$ : $$ Nil S Z * 4 R port P/E port 5 6 39 !: ) $ * >0? >;0? ><=0? &' 9 Electrical entry =$ 1 $ ! $ <@ G9 1 4 9 L9 4 5 9 * M9 4 5 9 * MN9 4 D9 R port P/E port DO9 MO9 LO9 LN9 4 H9 1 4 9 3 >1 ? >! ?
The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u.
MADE IN G IDF100150F i-2 i-6 IDX-OM-U021 i i-3 HFC IDF100150F i-3 i-7 IDX-OM-U021 i i-4 / 1 1.5 () IDF100150F i-4 / i-8 IDX-OM-U021 1 1 1-1 i.2.9 1 2 IDF100F-30 C.RV IDF100F-30-CRV1 IDF 100 F 30 C 1 2 G 3 K 100 125 150 ) 100kW 125kW P 150kW ) R V 30 AC200V(50Hz) AC200/220V(60Hz) 1 C 1 G 2 K 3 P R V 1-1 IDF100150F 1 1 IDX-OM-U021 1 1-2 1-2-1 (C) 1-2-2 G 1-2-3 K
M~-ill w". w r: L-+. !ill! L 3() same side I HI 49 65.5 55 5 SeIIh, Itrokt end within ::/-1.5mm or less ollhe above specIfied positioning order to mulmlzt the high magnetic fielll reslstabilhy. L, ' N X NZ NX NZ L, P i A A 0ND. o oNDI1'o A, U, NX bJ AppI bore size A ., E, 11 MM 'R, U. -. . No. CQ2 Single Rod Clevis (mm) C02 Double Rod Clevis (mm) ;1 AppI bon ...