Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A), Operation Manual: K (Operation
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual,
w w t t t q q q e IN OUT IN OUT IN OUT y y y e e r r r u u u Drain Drain Drain Parts list Material No.
6 o r t qy w e!7 iu !8 CJ1 CJP CJ2 JCM CM2 CM3 With air cushion CG1 CG1 q r !2 !1 !8 !4 w !0 e i !5 !9 !3 o !6 t !7 CG3 JMB MB MB1 CA2 CS1 CS2 Component Parts No. Description Material Note 1 Rod cover Aluminum alloy Hard anodized No.
How to Order 25A-LEFS 25 H R B 200 S 1 6N 1 q r w e t u y i o !0 !1 !
(No dustproof net is included.) w Replacement type dustproof filter HRS-FL002 5 filters per set Size: 300 x 370 w r Particle Filter Set Removes foreign objects in the circulating fluid.
For connector cable of M8 connector, refer to page 1-5-78. 1-5-6 4/5 Port Solenoid Valve Rubber Seal Series SYJ3000 Construction (A) 4 (B) 2 (A) 4 (B) 2 2 position single 2 position double 5 (R) 3 (R) 1 (P) 5 (R) 3 (R) 1 (P) t e q t r w qr w (B) 2 (A) 4 (B) 2 (A) 4 SV SZ u u 3 (R) 1 (P) 5 (R) 3 (R) 1 (P) 5 (R) SY y 3 position closed center/exhaust center/pressure center SYJ 3 position closed
Component Parts No. q w e r t y No. u i o !0 !