SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20CF-R-A2-W"

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]

2 x P (Plug) 2 x P D 2 x P (Plug) GB GA S Q JC J K PD C + Stroke FB FA G A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB H J JC K L MM ML NN 12 (10 x 2) 10, 20, 30, 50, 100 33 24.5 6 6.5 2 17 11 5.5 58 8.5 1.5 8.5 11 M3 x 0.5 7.5 M2.5 x 0.45 16 (12 x 2) 33 24.5 6 6.5 2 18 11 5.5 64 9 3 9 11 M4 x 0.7 10 M3 x 0.5 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z 12 (10 x

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

1361213613PVQ Note 1) In the case of A1 and B1, a pressure gauge or a plug is mounted on the body side, while in case of A2 and B2, on the manifold side.

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 81 lb

Miniature Fittings Stainless Steel 316 MS Series RoHS Applicable Tubes: 3.2, 4, 6 Connection Thread: M5, R 1/8 For use in corrosive environments Stainless steel 316 Compact piping space Tube has a large retaining force. Hose nipple assures easy installation and removal. Line up various types Possible for special tubing in the same direction.

Model: 520 (2.0 to 16.0 L/min), Thread Type: R (Rc), Port Size: 04 (1/2), I/O Specifications: A2 (IN1: 4-20mA, IN2: External Control Input, OUT1: 4-20mA), Lead Wire: N (None), Bracket: R (with Bracket), Operation Manual: Y (None)

When sum of load rate does not exceed 1, it is possible to use. 1+2+3<1 163 Series MXP Precision Air Slide Table How To Order How to Select Allowable load:W(N) Fig. 1 Over hung:Ln(mm), Corrected value for center position distance of moment:An(mm) Fig. 2 Pitch moment Yawing moment Roll moment W L2 A2 L1 A1 L3 A3 Mp Mr My Static moment Kinetic moment W W W L2 A2 L3 A3 L1 A1 W Mp Mr My W W

mm 176 mm HECR012-W2 HRCR010-A2 Air-cooled Air-cooled Water-cooled 200 W, 400 W, 510 W 800 W, 1 kW 800 W, 1.2 kW Mountable in a 19-inch rack Space can be saved by mounting multiple pieces of equipment together in a single rack.

W W 1 1 W W 2 2 1 1 11 11 12 12 1 32 - 7.3 () 12 1.CW [CW] 2.CCW [CCW] 12 1. [] 2.

W W 1 1 W W 2 2 1 1 11 11 12 12 1 32 - 73 () 12 1. CW [CW] 2. CCW [CCW] 12 1. [] 2.

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount